Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Skyhoj Olsen, T.
Right arrow Articles by Lassen, N. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Skyhoj Olsen, T.
Right arrow Articles by Lassen, N. A.

Stroke, Vol 12, 736-744, Copyright © 1981 by American Heart Association


ARTICLES

Focal cerebral ischemia measured by the intra-arterial 133xenon method. Limitations of 2-dimensional blood flow measurements

T Skyhoj Olsen, B Larsen, E Bech Skriver, E Enevoldsen and NA Lassen

The limitations of 2-dimensional isotope techniques in the study of focal cerebral ischemia were investigated using the intra-carotid 133 xenon injection method and a 254 multidetector scintillation camera. To make sure that the detectors "look" directly on infarcted areas, only patients with infarcts involving cortical surface structures were included in the study. Eleven such patients were found among 43 consecutive patients with completed stroke, all investigated with CT- scan. The blood supply to the infarcted areas was evaluated using 3 different approaches: 1) The first minute washout of 133 xenon (rCBF), 2) the initial distribution of isotope during the first 5 sec and 3) the cumulated counts recorded during 15 min. Compton scatter and the "look through phenomenon" were responsible for the majority of counts recorded from the infarcted areas and the blood flow recorded was found to be grossly overestimated and much more influenced by the blood flow in the surroundings than in the ischemic area itself. However, using the 3 approaches, infarcted areas were always disclosed by our equipment. It is concluded that 2-dimensional isotope technique is not reliable for quantifying focal ischemic lesions. The method should be limited to the qualitative demonstration of the ischemic lesions for which it is fully reliable.


This article has been cited by other articles:


Home page
StrokeHome page
W. A. Kofke, P. Brauer, R. Policare, S. Penthany, D. Barker, and J. Horton
Middle Cerebral Artery Blood Flow Velocity and Stable Xenon-Enhanced Computed Tomographic Blood Flow During Balloon Test Occlusion of the Internal Carotid Artery
Stroke, September 1, 1995; 26(9): 1603 - 1606.
[Abstract] [Full Text]


Home page
Vasc MedHome page
T. S. Olsen
Migraine: still a vascular illness?
Vascular Medicine, September 1, 1991; 2(2): 147 - 159.
[PDF]