Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1987;18:1011-1017

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Leary, D. H.
Right arrow Articles by Toole, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Leary, D. H.
Right arrow Articles by Toole, J. F.

Stroke, Vol 18, 1011-1017, Copyright © 1987 by American Heart Association


ARTICLES

Measurement variability of carotid atherosclerosis: real-time (B-mode) ultrasonography and angiography

DH O'Leary, FA Bryan, MW Goodison, MD Rifkin, R Gramiak, M Ball, MG Bond, RA Dunn, BB Goldberg and JF Toole
Department of Diagnostic Radiology, New England Deaconess Hospital, Boston, MA 02215.

To quantify the within- and between-reader agreement of carotid B-mode ultrasonography and angiography interpretation, images from 117 patients examined by both modalities were read multiple times. Angiographic measurements were more reproducible than those of B-mode scans for all parameters except lesion width, but variations for B-mode scan measurements were similar to those for angiographic measurements. Within-reader agreement on the presence of ulceration was substantial for both modalities, whereas between-reader agreement was poor for B- mode scan and only moderate for angiography.


This article has been cited by other articles:


Home page
CirculationHome page
J. J. Cao, A. M. Arnold, T. A. Manolio, J. F. Polak, B. M. Psaty, C. H. Hirsch, L. H. Kuller, and M. Cushman
Association of Carotid Artery Intima-Media Thickness, Plaques, and C-Reactive Protein With Future Cardiovascular Disease and All-Cause Mortality: The Cardiovascular Health Study
Circulation, July 3, 2007; 116(1): 32 - 38.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R.L. Cuffe and P.M. Rothwell
Effect of Nonoptimal Imaging on the Relationship Between the Measured Degree of Symptomatic Carotid Stenosis and Risk of Ischemic Stroke
Stroke, July 1, 2006; 37(7): 1785 - 1791.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. E. Heiserman
Measurement Error of Percent Diameter Carotid Stenosis Determined by Conventional Angiography: Implications for Noninvasive Evaluation
AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 2102 - 2107.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
T. J. Wang, B.-H. Nam, P. W.F. Wilson, P. A. Wolf, D. Levy, J. F. Polak, R. B. D'Agostino, and C. J. O'Donnell
Association of C-Reactive Protein With Carotid Atherosclerosis in Men and Women: The Framingham Heart Study
Arterioscler. Thromb. Vasc. Biol., October 1, 2002; 22(10): 1662 - 1667.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
P. M. Rothwell, S. T. Pendlebury, J. Wardlaw, and C. P. Warlow
Critical Appraisal of the Design and Reporting of Studies of Imaging and Measurement of Carotid Stenosis
Stroke, June 1, 2000; 31(6): 1444 - 1450.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
O. Joakimsen, K. H. Bonaa, and E. Stensland-Bugge
Reproducibility of Ultrasound Assessment of Carotid Plaque Occurrence, Thickness, and Morphology : The Tromso Study
Stroke, November 1, 1997; 28(11): 2201 - 2207.
[Abstract] [Full Text]


Home page
StrokeHome page
T. Mannami, M. Konishi, S. Baba, N. Nishi, and A. Terao
Prevalence of Asymptomatic Carotid Atherosclerotic Lesions Detected by High-Resolution Ultrasonography and Its Relation to Cardiovascular Risk Factors in the General Population of a Japanese City : The Suita Study
Stroke, March 1, 1997; 28(3): 518 - 525.
[Abstract] [Full Text]


Home page
StrokeHome page
M. A. Espeland, T. E. Craven, W. A. Riley, J. Corson, A. Romont, and C. D. Furberg
Reliability of Longitudinal Ultrasonographic Measurements of Carotid Intimal-Medial Thicknesses
Stroke, March 1, 1996; 27(3): 480 - 485.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
M. Massonneau, Ph. Caillard, L. de Chassey, X. Mouren, B. Thebault, and M. Cloarec
Short-Term Evaluation of Plaque Area Measurement Reproducibility from Computer-Assisted Sonography
Angiology, May 1, 1995; 46(5): 375 - 381.
[Abstract] [PDF]


Home page
StrokeHome page
A. Iannuzzi, T. Wilcosky, M. Mercuri, P. Rubba, F. A. Bryan, and M. G. Bond
Ultrasonographic Correlates of Carotid Atherosclerosis in Transient Ischemic Attack and Stroke
Stroke, April 1, 1995; 26(4): 614 - 619.
[Abstract] [Full Text]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
M. Langsfeld and E. S. Weinstein
Carotid Artery Plaque Morphology: Ultrasonographic Appearance and its Role in the Development of Cerebrovascular Symptoms
Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1991; 4(2): 1 - 15.
[PDF]


Home page
J Child NeurolHome page
W. M. McKinney
The Role of the Neurologist in Neurosonology
J Child Neurol, January 1, 1989; 4(1_suppl): S3 - S4.
[PDF]