Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1971;2:1-10

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BOYSEN, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by BOYSEN, G.

(Stroke. 1971;2:1.)
© 1971 American Heart Association, Inc.


Cerebral Blood Flow Measurement as a Safeguard During Carotid Endarterectomy

GUDRUN BOYSEN M.D.1

1 The Surgical Laboratory of Circulation Research, Surgical Department D, The University Hospital Rigshospitalet, Copenhagen, Denmark

Intraoperative measurement of regional cerebral blood flow (rCBF) by the 133Xe intracarotid injection technique was performed in 17 patients operated on for stenosis of the internal carotid artery. Mean rCBF decreased from 51 ml/100 gm x minute before endarterectomy to 30 ml/100 gm x minute when the internal carotid artery was clamped, a reduction of 41%. Postoperative aggravation of neurological deficits was observed in five patients in whom rCBF was at or below 30 ml/100 gm x minute during the period of carotid clamping, indicating a critical lower limit of rCBF of this magnitude. Flow reduction below this limit was tolerated only if the occlusion time was short. A critical time/flow relation is suggested.

Distal internal carotid artery blood pressure during clamping (measured in eight cases) was poorly correlated to rCBF (r = 0.62, 0.1 > P > 0.05).


Key Words: 133Xe • carotid stenosis • cerebrovascular disease • internal carotid artery pressure




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
Carotid Artery Balloon Test Occlusion
AJNR Am. J. Neuroradiol., September 1, 2001; 22(2007): 8S - 9S.
[Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
E. S. Lee, D. L. Melnyk, M. A. Kuskowski, and S. M. Santilli
Correlation of Cerebral Oximetry Measurement with Carotid Artery Stump Pressures During Carotid Endarterectomy
Vascular and Endovascular Surgery, September 1, 2000; 34(5): 403 - 409.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
H.C. Engell, G. Boysen, H.J. Ladegaard-Pedersen, and H. Henriksen
Cerebral Blood Flow before and After Carotid Endarterectomy
Vascular and Endovascular Surgery, January 1, 1972; 6(1): 14 - 19.
[PDF]