(Stroke. 1995;26:2048-2052.)
© 1995 American Heart Association, Inc.
Articles |
From the Department of Neurology, University at Lübeck (M.K., G.S.), and Byk Gulden Pharmaceuticals, Clinical Pharmacology, Konstanz (P.S., K.-D.B., H.B., W.W.), Germany.
Correspondence to Prof Dr M. Kaps, Klinik für Neurologie, Universität zu Lübeck, Ratzeburger Allee 160, D-23538 Lübeck, Germany.
Background and Purpose Transcranial ultrasound diagnostics are particularly hindered by insufficient ultrasound penetration through the temporal bone. The use of ultrasonic contrast media to enhance the Doppler signal is an important step toward the solution of this problem. In the present study we investigated the tolerability and the diagnostic value of a new intravenous transpulmonary ultrasonic contrast medium, BY963.
Methods In two phase I studies, 8 healthy volunteers received a spherosome suspension containing a phospholipid as the active ingredient. The intravenous injection was performed in three doses (2.5, 5, and 10 mL) at four different injection rates (0.25, 0.5, and 1 mL/s and bolus). The duration and degree of the signal enhancement were measured by two transcranial ultrasonic procedures presently used in clinical practice: transcranial Doppler sonography (TCD) and transcranial color-coded sonography (TCCS). The assessment of tolerability was based on chemical laboratory parameters and hemodynamic data (heart rate, blood pressure, electrocardiogram) and on questionnaires relating to general well-being.
Results BY963 was tolerated without complications. All 38 administrations of the echo contrast medium produced a marked increase in the TCD signal (>30 dB) in the intracranial basal cerebral arteries. To obtain the optimum time window for diagnostic use, higher doses with slower injection rates are advantageous. The duration of optimal contrasting was 42 to 68 seconds (TCD) and 12 to 132 seconds (TCCS), depending on the method and mode of administration. Bolus injections gave rise to an increased incidence of color artifacts.
Conclusions BY963 significantly improves intracranial Doppler imaging while being well tolerated. The signal enhancement lasts long enough for TCCS to display all basal cerebral arteries after just one injection.
Key Words: cerebrovascular disorders diagnostic imaging transcranial Doppler ultrasonics
This article has been cited by other articles:
![]() |
G. Deklunder Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C51 - C55. [Abstract] [PDF] |
||||
![]() |
T. Postert, B. Braun, S. Meves, O. Koster, H. Przuntek, S. Weber, and T. Buttner Contrast-Enhanced Transcranial Color-Coded Sonography in Acute Hemispheric Brain Infarction Stroke, September 1, 1999; 30 (9): e1819 - 1826. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Postert, A. Muhs, S. Meves, J. Federlein, H. Przuntek, and T. Buttner Transient Response Harmonic Imaging : An Ultrasound Technique Related to Brain Perfusion Stroke, September 1, 1998; 29(9): 1901 - 1907. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. G. Nabavi, D. W. Droste, V. Kemeny, G. Schulte-Altedorneburg, S. Weber, and E. B. Ringelstein Potential and Limitations of Echocontrast-Enhanced Ultrasonography in Acute Stroke Patients : A Pilot Study Stroke, May 1, 1998; 29(5): 949 - 954. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Postert, J. Federlein, B. Braun, O. Koster, C. Bornke, H. Przuntek, T. Buttner, R. W. Baumgartner, M. Arnold, F. Gonner, et al. Contrast-Enhanced Transcranial Color-Coded Real-Time Sonography: A Reliable Tool for the Diagnosis of Middle Cerebral Artery Trunk Occlusion in Patients With Insufficient Temporal Bone Window • Response Stroke, May 1, 1998; 29(5): 1070 - 1073. [Full Text] |
||||
![]() |
S. Knecht, M. Deppe, A. Ebner, H. Henningsen, T. Huber, H. Jokeit, and E.-B. Ringelstein Noninvasive Determination of Language Lateralization by Functional Transcranial Doppler Sonography : A Comparison With the Wada Test Stroke, January 1, 1998; 29(1): 82 - 86. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Baumgartner, M. Arnold, F. Gonner, I. Staikow, C. Herrmann, A. Rivoir, and R. M. Muri Contrast-Enhanced Transcranial Color-Coded Duplex Sonography in Ischemic Cerebrovascular Disease Stroke, December 1, 1997; 28(12): 2473 - 2478. [Abstract] [Full Text] |
||||
![]() |
G. Seidel and M. Kaps Harmonic Imaging of the Vertebrobasilar System Stroke, August 1, 1997; 28(8): 1610 - 1613. [Abstract] [Full Text] |
||||
![]() |
M. Kaps, P. Schaffer, K.-D. Beller, K.-D. Eng, G. Seidel, H. Bliesath, E. Diletti, and E. Eng Characteristics of Transcranial Doppler Signal Enhancement Using a Phospholipid-Containing Echocontrast Agent Stroke, May 1, 1997; 28(5): 1006 - 1008. [Abstract] [Full Text] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1995 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |