Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1995;26:203-209

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Otis, S.
Right arrow Articles by Boyajian, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Otis, S.
Right arrow Articles by Boyajian, R.
Right arrowPubmed/NCBI databases
*Substance via MeSH

(Stroke. 1995;26:203-209.)
© 1995 American Heart Association, Inc.


Articles

Contrast-Enhanced Transcranial Imaging

Results of an American Phase-Two Study

Shirley Otis, MD; Michael Rush, RVT Robert Boyajian, MD

From the Division of Neurology, Scripps Clinic and Research Foundation, La Jolla, Calif.

Correspondence to Shirley Otis, MD, Division of Neurology, Scripps Clinic and Research Foundation, 10666 No Torrey Pines Rd, La Jolla, CA 92037.

Background and Purpose Pulsed color Doppler imaging of cerebrovascular structures permits rapid visual identification of the intracranial vessels. In some patients, however, the clinical utility of transcranial ultrasound examinations is limited by poor tissue penetration and inadequate imaging of vessels. This phase-two clinical trial evaluates whether administration of an echocontrast agent in such ultrasound-refractory patients enhances image acquisition enough to yield meaningful diagnostic impressions.

Methods This is a phase-two clinical trial of safety and efficacy of the "galactose/palmitic acid–based microbubble preparation" Levovist injection (Berlex Laboratories). Thirty subjects with clinical indications for cerebrovascular imaging but refractory to transcranial Doppler studies were enrolled in a nonrandomized, single-center study. Echocontrast agent was administered intravenously in a tiered-dose protocol. Safety was determined by clinical and laboratory monitoring for 18 to 24 hours. Efficacy of contrast enhancement was determined by comparisons between each patient's precontrast (control) and postcontrast images.

Results No significant patient discomfort, side effects, or adverse reactions occurred that were due to the intravenous administration of the echocontrast agent. Optimal image enhancement was obtained using the 300-mg/mL concentration (3 g bolus) of contrast. Visualization of both individual arterial segments and/or the entire circle of Willis was demonstrated. Clinical confidence of diagnostic impressions was achieved in 77% (23/30) of subjects.

Conclusions The transpulmonary ultrasound contrast agent (Levovist injection) was easily administered and found to be safe in the 30 patients studied and increased the diagnostic utility of transcranial ultrasound in 77% of the patients studied.


Key Words: carotid arteries • clinical trials • contrast media • diagnostic imaging • ultrasonics




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
O. Oshikawa, S. Tanaka, T. Ioka, A. Nakaizumi, Y. Hamada, and T. Mitani
Dynamic Sonography of Pancreatic Tumors: Comparison with Dynamic CT
Am. J. Roentgenol., May 1, 2002; 178(5): 1133 - 1137.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Koga, K. Kimura, K. Minematsu, and T. Yamaguchi
Relationship between Findings of Conventional and Contrast-Enhanced Transcranial Color-Coded Real-Time Sonography and Angiography in Patients with Basilar Artery Occlusion
AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 568 - 571.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
G. Deklunder
Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C51 - C55.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
G. Melissano, R. Castellano, R. Zucca, and R. Chiesa
Results of Carotid Endarterectomy Performed with Preoperative Duplex Ultrasound Assessment Alone
Vascular and Endovascular Surgery, March 1, 2001; 35(2): 95 - 101.
[Abstract] [PDF]


Home page
StrokeHome page
R. A. Boyajian, S. M. Otis, D.W. Droste, R. Jurgens, R. Tietje, E.B. Ringelstein, and S. Weber
Continuous Infusion Versus Bolus Injection Of Ultrasound Contrast Agents in Vascular Doppler Flow Imaging Response
Stroke, September 1, 2000; 31 (9): 2266 - 2278.
[Full Text] [PDF]


Home page
StrokeHome page
G. Seidel, C. Algermissen, A. Christoph, L. Claassen, M. Vidal-Langwasser, and T. Katzer
Harmonic Imaging of the Human Brain : Visualization of Brain Perfusion With Ultrasound
Stroke, January 1, 2000; 31(1): 151 - 154.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. W. Droste, R. Jurgens, D. G. Nabavi, G. Schuierer, S. Weber, and E. B. Ringelstein
Echocontrast-Enhanced Ultrasound of Extracranial Internal Carotid Artery High-Grade Stenosis and Occlusion
Stroke, November 1, 1999; 30(11): 2302 - 2306.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
A. W. J. Hoksbergen, D. A. Legemate, D. T. Ubbink, and M. J. H. M. Jacobs
Success Rate of Transcranial Color-Coded Duplex Ultrasonography in Visualizing the Basal Cerebral Arteries in Vascular Patients Over 60 Years of Age
Stroke, July 1, 1999; 30(7): 1450 - 1455.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
T. Gerriets, G. Seidel, I. Fiss, B. Modrau, and M. Kaps
Contrast-enhanced transcranial color-coded duplex sonography: Efficiency and validity
Neurology, April 1, 1999; 52(6): 1133 - 1133.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. M. Uggowitzer, C. Kugler, M. Riccabona, G. E. Klein, K. Leber, J. Simbrunner, and F. Quehenberger
Cerebral Arteriovenous Malformations: Diagnostic Value of Echo-Enhanced Transcranial Doppler Sonography Compared with Angiography
AJNR Am. J. Neuroradiol., January 1, 1999; 20(1): 101 - 106.
[Abstract] [Full Text]


Home page
StrokeHome page
D. G. Nabavi, D. W. Droste, V. Kemeny, G. Schulte-Altedorneburg, S. Weber, and E. B. Ringelstein
Potential and Limitations of Echocontrast-Enhanced Ultrasonography in Acute Stroke Patients : A Pilot Study
Stroke, May 1, 1998; 29(5): 949 - 954.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Postert, J. Federlein, B. Braun, O. Koster, C. Bornke, H. Przuntek, T. Buttner, R. W. Baumgartner, M. Arnold, F. Gonner, et al.
Contrast-Enhanced Transcranial Color-Coded Real-Time Sonography: A Reliable Tool for the Diagnosis of Middle Cerebral Artery Trunk Occlusion in Patients With Insufficient Temporal Bone Window • Response
Stroke, May 1, 1998; 29(5): 1070 - 1073.
[Full Text]


Home page
StrokeHome page
R. W. Baumgartner, M. Arnold, F. Gonner, I. Staikow, C. Herrmann, A. Rivoir, and R. M. Muri
Contrast-Enhanced Transcranial Color-Coded Duplex Sonography in Ischemic Cerebrovascular Disease
Stroke, December 1, 1997; 28(12): 2473 - 2478.
[Abstract] [Full Text]


Home page
StrokeHome page
M. Kaps, P. Schaffer, K.-D. Beller, K.-D. Eng, G. Seidel, H. Bliesath, E. Diletti, and E. Eng
Characteristics of Transcranial Doppler Signal Enhancement Using a Phospholipid-Containing Echocontrast Agent
Stroke, May 1, 1997; 28(5): 1006 - 1008.
[Abstract] [Full Text]


Home page
StrokeHome page
R. W. Baumgartner, C. Schmid, and I. Baumgartner
Comparative Study of Power-Based Versus Mean Frequency-Based Transcranial Color-Coded Duplex Sonography in Normal Adults
Stroke, January 1, 1996; 27(1): 101 - 104.
[Abstract] [Full Text]


Home page
StrokeHome page
M. Kaps, P. Schaffer, K.-D. Beller, G. Seidel, H. Bliesath, and W. Wurst
Phase I: Transcranial Echo Contrast Studies in Healthy Volunteers
Stroke, November 1, 1995; 26(11): 2048 - 2052.
[Abstract] [Full Text]