Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Samra, S. K.
Right arrow Articles by Stanley, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Samra, S. K.
Right arrow Articles by Stanley, J. C.

(Stroke. 1996;27:49-55.)
© 1996 American Heart Association, Inc.


Articles

Cerebral Oximetry in Patients Undergoing Carotid Endarterectomy Under Regional Anesthesia

Presented at the 69th annual meeting of the International Anesthesia Research Society, Honolulu, Hawaii, March 10-14, 1995.

Satwant K. Samra, MD; Pema Dorje, MD; Gerald B. Zelenock, MD James C. Stanley, MD

From the Departments of Anesthesiology (S.K.S., P.D.) and Surgery (G.B.Z., J.C.S.), Section of Vascular Surgery, University of Michigan Medical Center, Ann Arbor.

Correspondence to Satwant K. Samra, MD, Department of Anesthesiology, 1G323 University Hospital, Box 0048, 1500 E Medical Center Dr, Ann Arbor, MI 48109. E-mail satsam@umich.edu.

Background and Purpose Near-infrared spectroscopy is a technique that can potentially monitor changes in cerebral oxygenation. There are at present limited clinical data regarding the value of this technology in relating neurological outcome to cerebrovascular hemoglobin oxygen saturation (ScO2). This investigation reports changes in ScO2 due to carotid cross-clamping during carotid endarterectomy in awake patients.

Methods ScO2 was monitored in 38 adult patients undergoing 41 carotid endarterectomies under regional anesthesia. Ipsilateral and contralateral hemispheres were monitored simultaneously during 36 operations, with ipsilateral monitoring alone in the remaining 5 operations.

Results No significant difference was detected between ipsilateral and contralateral ScO2 during preclamp or postclamp periods. Carotid cross-clamping caused a statistically significant (P<.01) decrease in the ipsilateral ScO2, which decreased from 71.8±6.91% to 65.8±8.2%, while the contralateral ScO2 remained stable at 70.5±7.5% and 70.3±7.9%. The change in ipsilateral ScO2 ranged from +2.6% to -28.6% of the preclamp value. The difference between ipsilateral and contralateral ScO2 during cross-clamping was statistically significant (P<.001). The duration of cross-clamping was 39±11 minutes (range, 18 to 89 minutes). The decrease in ipsilateral ScO2 was highly variable from patient to patient and did not correlate with the duration of cross-clamping.

Conclusions These results suggest that carotid artery occlusion causes a statistically significant but variable decrease in ScO2 in the majority of patients. Data in this investigation provide a range of ScO2 values that was not associated with a clinically detectable neurological dysfunction.


Key Words: carotid endarterectomy • cerebral ischemia • hypoxia • spectroscopy, near-infrared




This article has been cited by other articles:


Home page
Br J AnaesthHome page
S. J. Howell
Carotid endarterectomy
Br. J. Anaesth., July 1, 2007; 99(1): 119 - 131.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
P. G. Al-Rawi and P. J. Kirkpatrick
Tissue Oxygen Index: Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy
Stroke, November 1, 2006; 37(11): 2720 - 2725.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
K. Orihashi, T. Sueda, K. Okada, and K. Imai
Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion
Eur. J. Cardiothorac. Surg., November 1, 2004; 26(5): 907 - 911.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
G Naulaers, G Morren, S Van Huffel, P Casaer, and H Devlieger
Cerebral tissue oxygenation index in very premature infants
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2002; 87(3): F189 - 192.
[Abstract] [Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
E. S. Lee, D. L. Melnyk, M. A. Kuskowski, and S. M. Santilli
Correlation of Cerebral Oximetry Measurement with Carotid Artery Stump Pressures During Carotid Endarterectomy
Vascular and Endovascular Surgery, September 1, 2000; 34(5): 403 - 409.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
P. L. Madsen, C. Skak, A. Rasmussen, and N. H. Secher
Interference of Cerebral Near-Infrared Oximetry in Patients with Icterus
Anesth. Analg., February 1, 2000; 90(2): 489 - 489.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
U. Beese, H. Langer, W. Lang, and M. Dinkel
Comparison of Near-Infrared Spectroscopy and Somatosensory Evoked Potentials for the Detection of Cerebral Ischemia During Carotid Endarterectomy
Stroke, October 1, 1998; 29(10): 2032 - 2037.
[Abstract] [Full Text] [PDF]