Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1997;28:2453-2456

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Droste, D. W.
Right arrow Articles by Ringelstein, E. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Droste, D. W.
Right arrow Articles by Ringelstein, E. B.

(Stroke. 1997;28:2453-2456.)
© 1997 American Heart Association, Inc.


Articles

Oxygen Inhalation Can Differentiate Gaseous From Nongaseous Microemboli Detected by Transcranial Doppler Ultrasound

Dirk W. Droste, MD; Tjark Hansberg; Vendel Kemény, MD; Dieter Hammel, MD; Gernot Schulte-Altedorneburg; Darius G. Nabavi, MD; Manfred Kaps, MD; Hans H. Scheld, MD; E. Bernd Ringelstein, MD

From the Departments of Neurology (D.W.D., T.H., V.K., G.S.-A., D.G.N., E.B.R.) and Cardiothoracic and Vascular Surgery (D.H., H.H.S.), University of Münster, and Department of Neurology, Medical University of Lübeck (M.K.) (Germany).

Correspondence to Dr Dirk W. Droste, Klinik und Poliklinik für Neurologie der WWU Münster, Albert-Schweitzer-Str 33, D-48129 Münster, Germany.

Background and Purpose Clinically silent circulating microemboli can be detected by transcranial Doppler sonography. The composition of these emboli in different clinical conditions is unclear.

Methods We performed 1-hour transcranial Doppler sonographic recordings from the middle cerebral or posterior cerebral artery in 20 patients with mechanical prosthetic heart valves, in 78 patients with an arterial embolic source, and in 20 control subjects. During 30 minutes of this recording, the patients inspired room air and 6 L of oxygen per minute via a loosely fitting facial mask; during the remaining 30 minutes, they breathed room air only.

Results There was a significant decline of embolic signals (ES) under oxygen in the patients with mechanical prosthetic cardiac valves (144 ES without oxygen versus 63 ES with oxygen; P=.002) but not in the patients with arterial embolic sources (145 ES without oxygen versus 135 ES with oxygen; P=NS). In the control subjects, no ES were found.

Conclusions ES in patients with mechanical prosthetic cardiac valves correspond mainly to gas bubbles. Oxygen inhibits the cavitation process of mechanical prosthetic heart valves or speeds up redissolution of gas bubbles generated by cavitation. In contrast, solid microemboli originating from thrombus or atheroma cannot be suppressed by oxygen inhalation. This simple method of oxygen inhalation should help to clarify the composition of microemboli in various clinical and experimental settings.


Key Words: cerebral embolism • cerebrovascular disorders • heart valve prosthesis • oxygen • ultrasonics




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Guerrieri Wolf, B. P. Choudhary, Y. Abu-Omar, and D. P. Taggart
Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 512 - 520.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. Dittrich and E. B. Ringelstein
Occurrence and Clinical Impact of Microembolic Signals During or After Cardiosurgical Procedures
Stroke, February 1, 2008; 39(2): 503 - 511.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. H. Thoennissen, M. Schneider, A. Allroggen, M. Ritter, R. Dittrich, C. Schmid, H. H. Scheld, E. B. Ringelstein, and D. G. Nabavi
High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device
J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 1159 - 1166.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M. Perthel, S. Kseibi, A. Bendisch, and J. Laas
The dynamic bubble trap reduces microbubbles in extracorporeal circulation and high intensity transient signals in the middle cerebral artery: a case report
Perfusion, September 1, 2003; 18(5): 325 - 329.
[Abstract] [PDF]


Home page
StrokeHome page
J. H. Rapp, X. M. Pan, B. Yu, R. A. Swanson, R. T. Higashida, P. Simpson, and D. Saloner
Cerebral Ischemia and Infarction From Atheroemboli <100 {micro}m in Size
Stroke, August 1, 2003; 34(8): 1976 - 1980.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. G. Nabavi, J. Stockmann, C. Schmid, M. Schneider, D. Hammel, H. H. Scheld, and E. B. Ringelstein
Doppler microembolic load predicts risk of thromboembolic complications in Novacor patients
J. Thorac. Cardiovasc. Surg., July 1, 2003; 126(1): 160 - 167.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Laas, S. Kseibi, M. Perthel, A. Klingbeil, L'E. El-Ayoubi, and A. Alken
Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes
Eur. J. Cardiothorac. Surg., January 1, 2003; 23(1): 93 - 96.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. Russell and R. Brucher
Online Automatic Discrimination Between Solid and Gaseous Cerebral Microemboli With the First Multifrequency Transcranial Doppler
Stroke, August 1, 2002; 33(8): 1975 - 1980.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
D. W. Droste, K. Kuhne, R. M. Schaefer, and E. B. Ringelstein
Detection of microemboli in the subclavian vein of patients undergoing haemodialysis and haemodiafiltration using pulsed Doppler ultrasound
Nephrol. Dial. Transplant., March 1, 2002; 17(3): 462 - 466.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. J. Feiwell, L. Besmertis, R. Sarkar, D. A. Saloner, and J. H. Rapp
Detection of Clinically Silent Infarcts after Carotid Endarterectomy by Use of Diffusion-weighted Imaging
AJNR Am. J. Neuroradiol., April 1, 2001; 22(4): 646 - 649.
[Abstract] [Full Text]


Home page
StrokeHome page
V. Kemeny, D. W. Droste, S. Hermes, D. G. Nabavi, G. Schulte-Altedorneburg, M. Siebler, and E. B. Ringelstein
Automatic Embolus Detection by a Neural Network
Stroke, April 1, 1999; 30(4): 807 - 810.
[Abstract] [Full Text] [PDF]