(Stroke. 1997;28:906-911.)
© 1997 American Heart Association, Inc.
Articles |
From the Medical Research Council Cambridge Center for Brain Repair and Academic Neurosurgical Unit, and Department of Radiology (P.G.), Addenbrooke's Hospital, Cambridge, UK.
Correspondence to Mr Peter J. Kirkpatrick, Academic Neurosurgical Unit, Box 167, Block A, Level 4, Addenbrooke's Hospital, Cambridge CB2 2QQ, UK.
Background and Purpose The internal carotid (ICA) and external carotid (ECA) contributions to changing concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) during carotid endarterectomy were assessed with the use of near-infrared spectroscopy (NIRS).
Methods NIRS optodes were placed on the forehead with an interoptode distance of 6 cm, and laser-Doppler flowmetry (LDF) was used to monitor the change in skin blood flow between the optodes. Hb, HbO2, LDF, arterial blood pressure, and middle cerebral artery flow velocity were recorded continuously. The ECA was clamped 2 minutes before the ICA was clamped. Suitable multimodal recordings were achieved in 44 patients.
Results When the ECA was clamped, 76% of patients showed a fall in HbO2 and 65% an increase in Hb. When corrected for changes in arterial blood pressure, an accompanying fall in cutaneous LDF predicted the fall in HbO2 with high sensitivity (100%) and specificity (100%). Among those with no NIRS changes during ECA clamping, 56% had severe ECA stenosis or occlusion; none of these showed an accompanying fall in LDF. In contrast, when the ICA was clamped, substantial additional changes in NIRS occurred in 55% of cases, all of which were associated with a fall in flow velocity, but none with a change in LDF. Patients with a constant flow velocity after ICA clamping also showed no change in NIRS.
Conclusions Both the ECA and ICA vascular territories contribute to NIRS changes during carotid endarterectomy. The external carotid contribution to NIRS can be monitored with cutaneous LDF.
Key Words: carotid endarterectomy laser-Doppler flowmetry oxygen spectroscopy, near-infrared
This article has been cited by other articles:
![]() |
M. D. Stoneham, O. Lodi, T. C. D. de Beer, and J. W. Sear Increased Oxygen Administration Improves Cerebral Oxygenation in Patients Undergoing Awake Carotid Surgery Anesth. Analg., November 1, 2008; 107(5): 1670 - 1675. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Kurihara, A. Kikukawa, A. Kobayashi, and T. Nakadate Frontal cortical oxygenation changes during gravity-induced loss of consciousness in humans: a near-infrared spatially resolved spectroscopic study J Appl Physiol, October 1, 2007; 103(4): 1326 - 1331. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Valipour, A.D. McGown, H. Makker, C. O'Sullivan, and S.G. Spiro Some factors affecting cerebral tissue saturation during obstructive sleep apnoea Eur. Respir. J., August 1, 2002; 20(2): 444 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. G. Al-Rawi, P. Smielewski, and P. J. Kirkpatrick Evaluation of a Near-Infrared Spectrometer (NIRO 300) for the Detection of Intracranial Oxygenation Changes in the Adult Head Stroke, November 1, 2001; 32(11): 2492 - 2500. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Beese, H. Langer, W. Lang, and M. Dinkel Comparison of Near-Infrared Spectroscopy and Somatosensory Evoked Potentials for the Detection of Cerebral Ischemia During Carotid Endarterectomy Stroke, October 1, 1998; 29(10): 2032 - 2037. [Abstract] [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |