Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1997;28:1610-1613

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seidel, G.
Right arrow Articles by Kaps, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seidel, G.
Right arrow Articles by Kaps, M.

(Stroke. 1997;28:1610-1613.)
© 1997 American Heart Association, Inc.


Articles

Harmonic Imaging of the Vertebrobasilar System

G. Seidel, MD M. Kaps, MD

From the Department of Neurology, Lübeck (Germany) Medical University.

Correspondence to Günter Seidel, MD, Department of Neurology, Lübeck Medical University, Ratzeburger Allee 160, D-23538 Lübeck, Germany. E-mail DR.SEIDEL{at}T-ONLINE.DE

Background and Purpose Gas bubbles of ultrasound contrast agents resonate at frequencies used for diagnostic ultrasound and produce harmonics or multiples of the transmitted frequency. Processing of the second harmonic frequency results in a reduction of the signal-to-noise ratio and the signal-to-tissue artifacts. This study is the first to evaluate second harmonic imaging in the cerebral circulation.

Methods We used a duplex system (HP SONOS 2500) in connection with a 1.8/3.6-MHz (second harmonic) and a 2.5-MHz (conventional) sector transducer. Levovist (6.5 mL; 400 mg/mL) was injected intravenously for second harmonic and conventional color duplex imaging in 13 healthy volunteers (age range, 23 to 34 [median, 29] years).

Results When second harmonic imaging was compared with conventional color duplex imaging, more cerebellar arteries were detected (35 versus 31), the duration of blooming artifact was significantly reduced (7.9 versus 29.9 seconds; P=.03), and the duration of diagnostically useful signal enhancement was increased (248.5 versus 117.4 seconds; P=.0003), but the maximal investigation depth was reduced (8.4 versus 9.3 cm; P=.001). When conventional and second harmonic duplex were compared, there was a significant (P<.04) difference in the systolic blood flow velocity in the vertebral and basilar arteries.

Conclusions Second harmonic color duplex imaging in the vertebrobasilar system increases the time of diagnostic useful signal enhancement and produces a better spatial resolution compared with conventional color duplex imaging.


Key Words: contrast media • diagnostic imaging • ultrasonics • vertebrobasilar circulation




This article has been cited by other articles:


Home page
CirculationHome page
S.-J. Rim, H. Leong-Poi, J. R. Lindner, D. Couture, D. Ellegala, H. Mason, M. Durieux, N. F. Kassel, and S. Kaul
Quantification of Cerebral Perfusion With "Real-Time" Contrast-Enhanced Ultrasound
Circulation, November 20, 2001; 104(21): 2582 - 2587.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Seidel, C. Algermissen, A. Christoph, T. Katzer, M. Kaps, and R. W. Baumgartner
Visualization of Brain Perfusion With Harmonic Gray Scale and Power Doppler Technology : An Animal Pilot Study Editorial Comment: An Animal Pilot Study
Stroke, July 1, 2000; 31(7): 1728 - 1734.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Seidel, C. Algermissen, A. Christoph, L. Claassen, M. Vidal-Langwasser, and T. Katzer
Harmonic Imaging of the Human Brain : Visualization of Brain Perfusion With Ultrasound
Stroke, January 1, 2000; 31(1): 151 - 154.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Postert, A. Muhs, S. Meves, J. Federlein, H. Przuntek, and T. Buttner
Transient Response Harmonic Imaging : An Ultrasound Technique Related to Brain Perfusion
Stroke, September 1, 1998; 29(9): 1901 - 1907.
[Abstract] [Full Text] [PDF]