Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2000;31:1640-1645

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Droste, D. W.
Right arrow Articles by Ringelstein, E. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Droste, D. W.
Right arrow Articles by Ringelstein, E. B.
Related Collections
Right arrow Echocardiography
Right arrow Embolic stroke
Right arrow Doppler ultrasound, Transcranial Doppler etc.
Right arrow Risk Factors for Stroke

(Stroke. 2000;31:1640.)
© 2000 American Heart Association, Inc.


Original Contributions

Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts

Time Window and Threshold in Microbubble Numbers

Dirk W. Droste, MD; Karen Silling; Jörg Stypmann, MD; Matthias Grude, MD; Vendel Kemény, MD; Thomas Wichter, MD; Karsten Kühne E. Bernd Ringelstein, MD

From the Department of Neurology (D.W.D., K.S., V.K., K.K., E.B.R.) and Department of Cardiology and Angiology and Institute for Arteriosclerosis Research (J.S., M.G., T.W.), University of Münster (Germany).

Background and Purpose—Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of contrast agents and a Valsalva maneuver (VM) as provocation procedure. Currently, data on the appropriate timing of the VM, the use of a diagnostic time window, and a threshold in contrast agent microbubbles detected are insufficient.

Methods—Fifty-eight patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with injections of 10 mL of the commercial galactose-based contrast agent Echovist was applied in a randomized way: (1) no VM, (2) VM for 5 seconds starting 2 seconds after the beginning of contrast injection, (3) VM for 5 seconds starting 5 seconds after the beginning of contrast injection, (4) VM for 5 seconds starting 8 seconds after the beginning of contrast injection, and (5) repetitive short VMs in between 2 and 13 seconds after the beginning of contrast injection. In addition to the single tests, we also tested the sensitivity and specificity of combined results of the tests with VM.

Results—In 21 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-one patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 16 patients were only positive on at least 1 TCD investigation but negative during TEE. Test 3 was the most appropriate test when combined with the results of 1 of the other tests with VM. The highest sensitivities were achieved with a diagnostic time window of 40 seconds and when the presence of a single microbubble was sufficient for the diagnosis of a shunt.

Conclusions—TCD performed twice with 2 provocation maneuvers with Echovist is a sensitive method to identify TEE-proven cardiac right-to-left shunts. The VM should be performed for 5 seconds starting at 5 seconds after the beginning of contrast injection.


Key Words: cerebral embolism • cerebrovascular disorders • foramen ovale, patent • ultrasonography




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
E. Doufekias, A. Z. Segal, and J. R. Kizer
Cardiogenic and aortogenic brain embolism.
J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1049 - 1059.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Purandare, R C Oude Voshaar, C McCollum, A Jackson, and A Burns
Paradoxical embolisation and cerebral white matter lesions in dementia
Br. J. Radiol., January 1, 2008; 81(961): 30 - 34.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
O. I.I. Soliman, M. L. Geleijnse, F. J. Meijboom, A. Nemes, O. Kamp, P. Nihoyannopoulos, N. Masani, S. B. Feinstein, and F. J. Ten Cate
The use of contrast echocardiography for the detection of cardiac shunts
Eur J Echocardiogr, June 1, 2007; 8(3): s2 - s12.
[Abstract] [Full Text] [PDF]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
Y Iguchi, K Kimura, K Kobayashi, Y Ueno, and T Inoue
Ischaemic stroke with malignancy may often be caused by paradoxical embolism
J. Neurol. Neurosurg. Psychiatry, December 1, 2006; 77(12): 1336 - 1339.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
N. Purandare, A. Burns, K. J Daly, J. Hardicre, J. Morris, G. Macfarlane, and C. McCollum
Cerebral emboli as a potential cause of Alzheimer's disease and vascular dementia: case-control study
BMJ, May 13, 2006; 332(7550): 1119 - 1124.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. S. Albin, J. Wills, R. M. Schwend, S. Mazzucco, G. P. Anzola, J. R. Kizer, and R. B. Devereux
Patent foramen ovale and unexplained stroke.
N. Engl. J. Med., April 20, 2006; 354(16): 1753 - 1755.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
B. Draganski, W. Blersch, S. Holmer, H. Koch, A. May, U. Bogdahn, T. Holscher, and F. Schlachetzki
Detection of Cardiac Right-to-Left Shunts by Contrast-Enhanced Harmonic Carotid Duplex Sonography
J. Ultrasound Med., August 1, 2005; 24(8): 1071 - 1076.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G.P. Anzola, E. Morandi, F. Casilli, and E. Onorato
Does Transcatheter Closure of Patent Foramen Ovale Really "Shut the Door?": A Prospective Study With Transcranial Doppler
Stroke, September 1, 2004; 35(9): 2140 - 2144.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Devuyst, B. Piechowski-Jozwiak, T. Karapanayiotides, J.-W. Fitting, V. Kemeny, L. Hirt, L. A. Urbano, P. Arnold, G. van Melle, P.-A. Despland, et al.
Controlled Contrast Transcranial Doppler and Arterial Blood Gas Analysis to Quantify Shunt Through Patent Foramen Ovale
Stroke, April 1, 2004; 35(4): 859 - 863.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Zanchetta, L. Pedon, P. Maiolino, R. Wolk, T. Kara, and V. K. Somers
Obstructive Sleep Apnea and Patent Foramen Ovale * Response
Circulation, February 24, 2004; 109 (7): e69 - e69.
[Full Text] [PDF]


Home page
StrokeHome page
M. Saqqur, N. Dean, M. Schebel, M. D. Hill, A. Salam, A. Shuaib, and A. M. Demchuk
Improved Detection of Microbubble Signals Using Power M-Mode Doppler
Stroke, January 1, 2004; 35 (1): e14 - e17.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J. Draganov and T. W. L. Scheeren
Incidental detection of paradoxical air embolism with a transoesophageal Doppler probe inserted for measuring descending aortic blood flow
Br. J. Anaesth., April 1, 2003; 90(4): 520 - 522.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. K. Blersch, B. M. Draganski, S. R. Holmer, H. J. Koch, F. Schlachetzki, U. Bogdahn, and T. Holscher
Transcranial Duplex Sonography in the Detection of Patent Foramen Ovale
Radiology, December 1, 2002; 225(3): 693 - 699.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. W. Droste, S. Lakemeier, T. Wichter, J. Stypmann, R. Dittrich, M. Ritter, M. Moeller, M. Freund, and E. B. Ringelstein
Optimizing the Technique of Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts
Stroke, September 1, 2002; 33(9): 2211 - 2216.
[Abstract] [Full Text] [PDF]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
K Nedeltchev, M Arnold, A Wahl, M Sturzenegger, E E Vella, S Windecker, B Meier, and H P Mattle
Outcome of patients with cryptogenic stroke and patent foramen ovale
J. Neurol. Neurosurg. Psychiatry, March 1, 2002; 72(3): 347 - 350.
[Abstract] [Full Text] [PDF]