(Stroke. 2008;39:2986.)
© 2008 American Heart Association, Inc.
Original Contributions |
From the Departments of Radiology (P.W.S., E.R.B., S.K., L.R.G., R.G.G., M.H.L.) and Neurology (L.S.), Massachusetts General Hospital, Harvard Medical School, Boston, Mass.
Correspondence to Pamela W. Schaefer, MD, Department of Radiology, Division of Neuroradiology, Gray 273A, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114. E-mail pschaefer{at}partners.org
Background and Purpose— Our purpose was to determine (1) the correlation between quantitative CT and MR measurements of infarct core, penumbra, and mismatch; and (2) whether the difference between these measurements would alter patient selection for stroke clinical trials.
Methods— We studied 45 patients with acute middle cerebral artery stroke imaged a mean of 3.8 hours after onset (range, 0.48 to 8.35 hours) who underwent CT perfusion and MR diffusion (DWI)/perfusion imaging within 3 hours of each other. The DWI and MR-mean transit time (MTT) abnormalities were visually segmented using a semiautomated commercial analysis program. The CT-cerebral blood volume) and CT-MTT lesions were automatically segmented using a relative cerebral blood volume threshold of 0.56 and a relative MTT threshold of 1.50 on commercially available software. Percent mismatch was defined as [(MTT–DWI)/DWI volume]x100. Pearson correlation coefficients were calculated.
Results— There were significant correlations for DWI versus CT-cerebral blood volume lesion volumes (r2=0.88, P<0.001), for MR-MTT versus CT-MTT lesion volumes(r2=0.86, P<0.001), and for MR-MTT/DWI versus CT-MTT/CT-cerebral blood volume mismatch lesion volumes(r2=0.81, P<0.001). MR perfusion and CT perfusion agreed for determining: (1) infarct core < versus
100 mL in 41 of 45 (91.1%); (2) MTT lesion size < versus >2 cm diameter in 42 of 45 (93.3%); (3) mismatch < versus >20% in 41 of 45 (91.1%); and (4) inclusion versus exclusion from trial enrollment in 38 of 45 (84.4%) patients. Six of 7 disagreements were due to inadequate CT coverage.
Conclusion— Advanced MR and CT perfusion imaging measurements of core/penumbra mismatch for patient selection in stroke trials are highly correlated when CT perfusion coverage is sufficient to include most of the ischemic region. Although MR is currently the preferred imaging method for determining core and penumbra, CT perfusion is comparable and potentially more available.
Key Words: acute ischemic acute stroke CT MRI penumbra perfusion CT imaging perfusion MR imaging
This article has been cited by other articles:
![]() |
S. K. Natarajan, K. V. Snyder, A. H. Siddiqui, C. C. Ionita, L. N. Hopkins, and E. I. Levy Safety and Effectiveness of Endovascular Therapy After 8 Hours of Acute Ischemic Stroke Onset and Wake-Up Strokes Stroke, October 1, 2009; 40(10): 3269 - 3274. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Miteff, C. R. Levi, G. A. Bateman, N. Spratt, P. McElduff, and M. W. Parsons The independent predictive utility of computed tomography angiographic collateral status in acute ischaemic stroke Brain, August 1, 2009; 132(8): 2231 - 2238. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Schaefer, K. Mui, S. Kamalian, R. G. Nogueira, R. G. Gonzalez, and M. H. Lev Avoiding "Pseudo-Reversibility" of CT-CBV Infarct Core Lesions in Acute Stroke Patients After Thrombolytic Therapy: The Need for Algorithmically "Delay-Corrected" CT Perfusion Map Postprocessing Software Stroke, August 1, 2009; 40(8): 2875 - 2878. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Wintermark, H. A. Rowley, and M. H. Lev Acute Stroke Triage to Intravenous Thrombolysis and Other Therapies with Advanced CT or MR Imaging: Pro CT Radiology, June 1, 2009; 251(3): 619 - 626. [Full Text] [PDF] |
||||
![]() |
A.S. Ahmed, M. Zellerhoff, C.M. Strother, K.A. Pulfer, T. Redel, Y. Deuerling-Zheng, K. Royalty, D. Consigny, and D.B. Niemann C-Arm CT Measurement of Cerebral Blood Volume: An Experimental Study in Canines AJNR Am. J. Neuroradiol., May 1, 2009; 30(5): 917 - 922. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.-D. Heiss and A. G. Sorensen Advances in Imaging Stroke, May 1, 2009; 40(5): e313 - e314. [Full Text] [PDF] |
||||
![]() |
A.A. Konstas, G.V. Goldmakher, T.-Y. Lee, and M.H. Lev Theoretic Basis and Technical Implementations of CT Perfusion in Acute Ischemic Stroke, Part 1: Theoretic Basis AJNR Am. J. Neuroradiol., April 1, 2009; 30(4): 662 - 668. [Abstract] [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2008 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |