Stroke. 1995;26:1225-1230

This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brækken, S. K.
Right arrow Articles by Svennevig, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brækken, S. K.
Right arrow Articles by Svennevig, J.

(Stroke. 1995;26:1225-1230.)
© 1995 American Heart Association, Inc.


Articles

Incidence and Frequency of Cerebral Embolic Signals in Patients With a Similar Bileaflet Mechanical Heart Valve

Presented at the 19th International Joint Conference on Stroke and Cerebral Circulation, San Diego, Calif, February 17-19, 1994.

Sigrun K. Brækken, MD; David Russell, MD, PhD, FRCPE; Rainer Brucher, PhD Jan Svennevig, MD, PhD

From the Departments of Neurology and Surgery, Rikshospitalet, The National Hospital, University of Oslo, Norway; and the Institute of Medical Engineering, FH Ulm, Germany.

Correspondence to S.K. Brækken, MD, Department of Neurology, Rikshospitalet, The National Hospital, Pilestredet 32, N-0027 Oslo, Norway.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowSubjects and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background and Purpose The aim of this study was to determine the incidence and frequency of cerebral embolic signals in a patient population with the same mechanical heart valve using transcranial Doppler examination. Furthermore, it aimed to identify patient and valve characteristics that correlated with the occurrence of these signals.

Methods Ninety-two patients with Carbomedics valves and 15 healthy control subjects took part in the study. Thirty-six patients were examined before and immediately after valve implantation (group 1), 34 patients 1 year after surgery (group 2), and 22 patients 5 years after surgery (group 3). Cerebral embolic signals were detected using transcranial Doppler monitoring of the right middle cerebral artery.

Results Asymptomatic cerebral embolic signals were detected in 87% of the total 92 patients, in 77.8% of group 1 patients, in 91.2% of group 2 patients, and in 95.5% of group 3 patients. No cerebral embolic signals were detected in group 1 patients before surgery or in control subjects. The incidence (P=.04) and frequency (P=.002) of cerebral embolic signals increased significantly with longer duration of valve implantation. A significant positive correlation was also found between frequency of cerebral embolic signals and valve size (r=.4326, P=.00001). Median frequency of embolic signals in patients with a history suggestive of cerebrovascular events (n=14) was 60 signals per hour compared with 11 signals per hour in those with no such history (n=42; P=.04).

Conclusions The incidence and frequency of cerebral embolic signals increased with the duration of valve implantation. The frequency of these signals also was dependent on valve size. Patients who had experienced cerebrovascular symptoms had a higher frequency of cerebral embolic signals compared with those with no such signals. These results should be interpreted with caution but suggest that this method could be of help in assessing the risk of stroke in prosthetic heart valve patients and that prospective clinical studies should now be carried out.


Key Words: embolism • heart valve prosthesis • ultrasonics


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowSubjects and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Although many advances have been made in the design and construction of prosthetic heart valves since their introduction over 30 years ago, none of these protheses can compare with the normal human valve with regard to hemodynamic functioning or freedom from complications.1 2 3

Mechanical prosthetic valves offer satisfactory hemodynamic functioning and long-term durability, but they are thrombogenic and patients who receive them require long-term anticoagulation with warfarin. The frequency of thromboembolism in mechanical valve patients is 2% to 4% per patient-year despite anticoagulation and is twice as high in patients with a valve implanted in the mitral compared with the aortic position.2 3 The majority of these thromboembolic events involve the central nervous system,4 5 and their incidence is related to valve type2 3 4 and the presence of atrial fibrillation.5 Most valves appear to show the highest risk for thromboembolic events in the first 6 to 12 months after implantation.2 4

Advances in Doppler technology have made it possible to detect not only gaseous emboli6 7 but also emboli composed of solid elements that are frequently involved in cerebral embolism.7 8 9 This method has now been applied to mechanical heart valve patients, and clinical studies strongly suggest that subclinical cerebral embolic signals may be detected in the majority of patients.10 11 12 13 There are, however, considerable differences in the reported incidence and frequency of these signals, findings that at present remain unexplained.

The aims of this study were (1) to determine the incidence and frequency of cerebral embolic signals in a population of patients with similar mechanical heart valves and (2) to identify patient and valve characteristics that may correlate with the incidence and frequency of these signals.


*    Subjects and Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Subjects and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
A total of 92 prosthetic heart valve patients were admitted to the study after giving informed consent. The group consisted of 64 men and 28 women aged from 25 to 82 years, with a median of 64 years. Thirty-six patients took part in the study both before and after valve implantation, whereas the remaining 56 patients were examined on one occasion, 1 or 5 years after implantation surgery. Patients were excluded if Doppler examination of the precerebral or intracranial vessels showed stenosis or occlusion of the carotid, vertebral, or major intracranial arteries.

The preoperative cardiac diagnoses were as follows: aortic stenosis (n=28), aortic insufficiency (n=25), a combination of aortic stenosis and insufficiency (n=13), mitral stenosis (n=6), mitral insufficiency (n=8), a combination of mitral stenosis and insufficiency (n=4), or combined aortic and mitral valve disease (n=8). In 21 cases (22.8%), coronary artery surgery was also performed. All patients received a mechanical bileaflet Carbomedics valve14 ranging in diameter from 19 to 33 mm (median, 25 mm). The patients were divided into three groups.

Group 1
Group 1 included 36 patients, 27 men and 9 women aged 30 to 82 years (median, 63 years), who received an aortic (n=28), mitral (n=5), or aortic and mitral (n=3) valve. Before valve implantation, the mean left atrial diameter was 43 mm, the mean New York Heart Association (NYHA) functional class was 2.8, and 3 (8.3%) patients were in atrial fibrillation. In these patients, transcranial Doppler monitoring (TDM) was carried out 2 days before and again from 2 to 4 days after surgery.

Group 2
Group 2 included 34 patients, 23 men and 11 women aged 25 to 82 years (median, 67 years), who had received an aortic (n=28), mitral (n=5), or aortic and mitral valve (n=1) 1 year previously. Before valve implantation, the mean left atrial diameter was 44 mm, the mean NYHA class was 2.8, and 2 (5.9%) patients were in atrial fibrillation.

Group 3
Group 3 consisted of 22 patients, 14 men and 8 women aged 29 to 77 years (median, 63 years), who had received an aortic (n=13), mitral (n=8), or aortic and mitral valve (n=1) 5 years previously. Preoperatively, the mean left atrial diameter was 47 mm, the mean NYHA class was 2.9, and 5 (22.7%) patients were in atrial fibrillation.

Control Subjects
Fifteen elderly healthy individuals, 9 men and 6 women aged 67 to 84 (median, 70) years, with no history of cerebrovascular or cardiac disease served as control subjects. All had normal clinical neurological findings, and Doppler examination of the precerebral and major intracranial arteries was normal.

Transcranial Doppler Monitoring
Doppler examination of the right middle cerebral artery (MCA) was performed in all patients and control subjects with a TC2000S (Nicolet/EME) with a 2-MHz flat monitoring probe. Each monitoring period lasted for 30 minutes in patients and 60 minutes in the control subjects. A stable probe position was maintained using a Müller fixation system (Nicolet/EME) at a depth of 48 to 54 mm and at the angle giving the strongest Doppler signal from the MCA. All Doppler findings were recorded on videotape (Panasonic AG 7355, Matsushita Electrical Industrial).

Embolic Signals
Embolic signals were recognized using the following criteria: (1) audible short-lasting increases of the Doppler signal power, (2) red spots in the Doppler signal when its intensity was assessed using a color-coded signal intensity scale, and (3) an enhanced power increase (relative power increase above the background Doppler signal) of at least 4 dB measured with a specially designed algorithm.15 The number of embolic signals was presented as the median frequency of signals per hour with interquartile range defined as the 25th to the 75th centiles. Artifacts were assessed as being present when signal intensity increased simultaneously in both directions around the zero velocity line.

Neurological Symptoms and Signs
All patients were questioned regarding cerebrovascular symptoms and specifically asked whether he or she had experienced episodes with the following symptoms: (1) sudden difficulties with speech or understanding simple sentences, (2) sudden weakness or clumsiness in one or both limbs on the same side, (3) sudden numbness, tingling, or loss of feeling in one or both limbs on the same side, (4) sudden loss of balance or sensation of spinning, (5) sudden loss of vision in one eye or a part of one eye, and (6) sudden double vision. A clinical neurological examination was carried out after each TDM.

Coagulation and Hemolysis
After surgery all patients were treated with warfarin, and none were receiving antiplatelet drugs. Anticoagulation activity was measured in all patients with the thrombotest and converted into international normalized ratio (INR). Hematocrit (percent), lactate dehydrogenase (LDH; units per liter), haptoglobin (grams per liter), and hemoglobin in plasma (milligrams per deciliter) were measured, and reticulocytes (percent) were counted in groups 2 and 3. All blood samples were taken within 24 hours of the TDM.

Cardiac Evaluation
All patients had a clinical cardiological examination including an electrocardiogram (ECG) and an echocardiogram before valve implantation. In the early postoperative period, heart rhythm was monitored continuously on a scope, and ECGs were taken when a possible arrhythmia was observed. A clinical cardiological examination including an ECG was performed within 1 week of surgery and annually thereafter. Echocardiography was carried out if a patient had clinical symptoms or signs suggestive of valve dysfunction.

Statistics
Three independent groups of patients and two outcome variables, incidence and frequency of embolic signals, were considered. Group comparisons regarding the proportion of patients with embolic signals were performed using the Mantel-Haenszel test of linear trend with increasing odds ratio (OR) by time of exposure, ie, the time elapsed since valve implantation.16 We considered group 1 as the reference group with an OR of 1. As the distribution of the frequency of embolic signals was skewed, the Mann-Whitney or Kruskal-Wallis nonparametric test was used to compare groups of patients.

The following variables were analyzed for an association with the frequency of embolic signals: valve size, patient age at the time of Doppler examination, anticoagulation intensity, and blood parameters indicating hemolysis. The correlation coefficient measurements were performed using the nonparametric Spearman's correlation coefficient because of the nongaussian distribution of the variables.17 After univariate analysis, multivariate linear regression was used to identify independent prognostic factors.18 When analyzing the association between frequency of embolic signals and valve size, we used the multivariate regression model where size of the valves (19 mm to 33 mm) was dichotomized into large (>23 mm) versus small (<=23 mm).


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowSubjects and Methods
*Results
down arrowDiscussion
down arrowReferences
 
There was no significant difference between the three patient groups with regard to the preoperative characteristics of age, NYHA functional class, and left atrial diameter.

Incidence
Cerebral embolic signals were detected in 80 (87%) of the 92 patients with mechanical heart valves who took part in the study (Fig 1Down, Table 1Down).



View larger version (0K):
[in this window]
[in a new window]
 
Figure 1. Four microembolic signals in the middle cerebral artery of a patient with a Carbomedics valve in the mitral position examined with transcranial Doppler 1 year after implantation. The embolic signals (red) caused an intensity increase that was at least 15 dB greater than the background Doppler signal (blue). Each shade from left to right on the color scale (top) represents an increase in signal intensity of 3 dB. Blood flow velocities are shown in centimeters per second on the vertical axis, and time base on the horizontal axis is 2.5 seconds.


View this table:
[in this window]
[in a new window]
 
Table 1. Cerebral Embolic Signals and Patient Characteristics in 92 Patients With a Similar Mechanical Heart Valve

Assessment of the individual groups showed that none of the 36 patients in group 1 had embolic signals before valve implantation, whereas 28 (77.8%) did so 2 to 4 days after surgery. Cerebral embolic signals were also detected in 31 (91.2%) of the 34 group 2 patients 1 year after implantation and in 21 (95.5%) of the 22 group 3 patients examined 5 years after valve implantation (Table 1Up).

The risk for developing cerebral embolic signals with longer duration of valve implantation was assessed by comparing the proportion of patients with embolic signals in the three patient groups. Patient group 1 was used as a reference group and was given an OR of 1. Calculation of the OR for group 2 gave a value of 2.95 and a value of 6 for group 3. This risk of developing cerebral embolic signals increased significantly with longer duration of valve implantation (linear trend of P=.04) (Fig 2Down).



View larger version (9K):
[in this window]
[in a new window]
 
Figure 2. Bar graph shows risk for developing cerebral embolic signals and duration of valve implantation measured with the Mantel-Haenszel test of linear trend in 92 patients with Carbomedics heart valve prostheses. The immediate postoperative incidence was considered as a reference with an odds ratio of 1; the odds ratios after 1 and 5 years were 2.95 and 6, respectively.

Frequency
The median frequency of cerebral embolic signals was 6 per hour in group 1 (interquartile range [25th to 75th centiles], 2.5 to 24) and 6 (interquartile range, 2 to 66.5) in group 2 patients. In group 3 patients, the median frequency was 41 signals per hour (interquartile range, 10 to 112.5) (Table 1Up). The difference in frequency was significant when group 3 was compared with group 1 (P=.002). The difference in frequency was not significant between groups 2 and 3 (P=.09) and groups 2 and 1 (P=.3).

Valve Size
There was no significant difference when valve size was compared in the three patient groups (Table 2Down), except for valves in group 2 and group 3 patients (P=.04). The median frequency of embolic signals for the total patient population was significantly correlated to the size of the valve (Spearman's r=.4326, P=.00001) (Table 2Down, Fig 3Down). This was found to be independently true for patients with aortic valve replacement (Spearman's r=.4180, P=.0004). This correlation was not examined for the 18 patients with mitral valve prostheses because of the small number of patients. A multivariate analysis was performed where size of the valves and age were associated with frequency of embolic signals. This showed an association between size of the valves and the frequency of embolic signals when adjusted for age.


View this table:
[in this window]
[in a new window]
 
Table 2. Valve Size and Hematologic Parameters in the Three Patient Groups With Mechanical Heart Valves



View larger version (12K):
[in this window]
[in a new window]
 
Figure 3. Graph shows correlation between median frequency of cerebral embolic signals (number per hour) on the vertical axis and valve diameter (millimeters) on the horizontal axis in 69 patients with aortic and 18 with mitral Carbomedics heart valve prostheses. Overlapping data are indicated by numbers. Group 1 was examined before and 2 to 4 days after surgery; group 2 was examined 1 year and group 3 was examined 5 years after valve implantation.

Valve Position
For all patients, there was a significantly higher median frequency of embolic signals among the mitral valve patients (37 signals per hour) compared with the aortic valve patients (6 signals per hour) (P=.02) (Table 1Up). However, this difference could be explained by the larger diameters of the mitral valves (median diameter, 29 mm) compared with those of the aortic valves (median diameter, 24 mm).

Age
The frequency of embolic signals was inversely correlated with the age of the patient (Spearman's r=-.227, P=.03). This association was present when adjusted for valve position. Our results showed that valve size in younger patients was significantly (P=.04) larger than in older patients, which may explain the observed inverse association.

Atrial Fibrillation
Atrial fibrillation was present during the postoperative TDM in 7 group 1 patients (19.4%) and in 2 group 2 patients (5.9%), and 10 group 3 patients (45.5%) were in atrial fibrillation (Table 1Up). In the total patient population, the median frequency of embolic signals was 22 signals per hour in 19 patients with atrial fibrillation compared with 14 signals per hour in 73 patients with sinus rhythm (Table 1Up). This difference was not statistically significant (P=.4).

Cerebrovascular Events
None of the patients experienced new cerebrovascular symptoms during TDM. Cerebral embolic signals were not detected in 2 group 1 patients who were temporarily disoriented for time and place in the early postoperative period. Six (17.6%) of the 34 group 2 patients experienced acute cerebrovascular symptoms within 1 year of valve implantation (Table 1Up): 4 had transient ischemic attacks (TIAs), 1 a combination of amaurosis fugax and TIA, and 1 a hemispheric ischemic stroke with a residual mild hemiparesis. Eight (36.4%) of the 22 group 3 patients experienced acute cerebrovascular symptoms within 5 years of valve implantation, including 5 patients with TIA, 2 with amaurosis fugax, and 1 with a hemispheric ischemic stroke resulting in a slight aphasia (Table 1Up). This corresponds to a stroke incidence of 1.4 per 100 patient-years. The median frequency of embolic signals was 60 (interquartile range, 20.4 to 134) signals per hour in the 14 (25%) patients from groups 2 and 3 combined (n=56) who had experienced cerebrovascular symptoms compared with 11 (interquartile range, 2 to 66.5) signals per hour in the remaining 42 patients without symptoms (P=.04).

Blood Parameters
The median INR in group 2 patients was 2.6, 2.5 for those with aortic and 2.8 for those with mitral valves (P=.6). Among group 3 patients, the median INR was 2.6 for both valve locations (P=.9). The frequency of cerebral embolic signals was not associated with the anticoagulation intensity in the total patient population or when each of the three groups was assessed separately (Table 2Up). There was a significant positive correlation between the frequency of embolic signals and LDH levels for patients from groups 2 and 3 combined (Spearman's r=.4591, P=.0004) (Table 2Up). Furthermore, a significant correlation was found between LDH levels and valve size (Spearman's r=.5183, P=.00001). No correlation was found between the frequency of embolic signals and levels of hematocrit, reticulocytes, haptoglobin, or hemoglobin in plasma in these patients.

Cardiac Evaluation
At the time of the TDM, the mean NYHA class was 1.1 for group 2 and 1.5 for group 3 patients (P=.01). Transthoracic echocardiography was performed in 6 group 2 patients. The examined valve prostheses were found to be functioning normally. A paravalvular leak was found in 3 of the 8 (13.6%) group 3 patients who had transthoracic echocardiography.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowSubjects and Methods
up arrowResults
*Discussion
down arrowReferences
 
In this study, we found that the majority of patients with Carbomedics heart valves had asymptomatic cerebral embolic signals when examined with transcranial Doppler. Furthermore, we found that both the incidence and frequency of these embolic signals appeared to be at least partly dependent on the duration of valve implantation. These results provide further support for previous studies that report a high incidence of asymptomatic cerebral embolic signals in mechanical heart valve patients.10 11 12 13

There is discussion as to the exact Doppler characteristics of cerebral emboli. We therefore used three main criteria in this study: first, the audible signal and, second, the color-coded intensity scaling of the Doppler signal. Our third parameter was enhanced power, which was measured using a specially designed algorithm.15 Enhanced power is a measure of the relative power increase caused by an embolus compared with the normal background power due to flow in the MCA. We set a level of 4 dB for embolic signals, since this value exceeds the variations in enhanced power that are found in the normal MCA signal.

Our findings strongly suggest that the embolic signals were the result of valve implantation because these signals were not present in patients who were also examined before surgery, and they were not detected in the control subjects. Cerebral embolic signals have also been detected in patients with internal carotid artery stenosis or occlusion,19 20 but such patients were excluded from this study.

The composition and size of cerebral emboli in prosthetic heart valve patients is unknown. Cavitation-induced gas or vapor bubbles have been reported during in vitro testing of mechanical heart valve prostheses.21 22 23 24 25 26 27 However, these bubbles collapsed in less than 1 millisecond; it is therefore very unlikely that they last long enough to reach the cerebral circulation.22 Another possibility is that these signals are due to whole-blood emboli, in which case we would expect that their frequency would correlate with the degree of anticoagulation with warfarin. We did not find such a correlation, which is in agreement with previous reports.10 11 12 13 Finally, aggregation of red blood cells or platelets may represent the origin of these microembolic signals. It has been shown that there is an increased tendency for such aggregation in patients with mechanical heart valves.28 Furthermore, a clinical study in this patient group has shown that treatment with warfarin together with antiplatelet medication (acetylsalicylic acid) may reduce the frequency of cerebrovascular events when compared with treatment with warfarin and placebo.29

We found an increase in the incidence and frequency of cerebral embolic signals with longer duration of valve implantation. In vitro and in vivo studies have shown that cavitation may induce pitting, microcracking, and erosion of the pyrolytic carbonated surface of prosthetic heart valves.23 24 When cavitation occurs on a bileaflet valve, it may appear at the same localized area of the leaflet during each heart cycle, producing a cumulative effect on the valve surface.25 26 Erosions on the valve surface may then predispose to thrombus and embolus formation. This cumulative damaging effect caused by cavitation is one possible explanation for the increased incidence and frequency of cerebral embolic signals with duration of valve implantation.

Another main finding in this study was the positive correlation between signal frequency and valve diameter. Valve cross-sectional area may in itself be of importance, since the exposure of blood to artificial surfaces initiates a complex series of interrelated reactions, among which are adhesion and activation of platelets and white blood cells and the blood coagulation/fibrinolytic system, which may lead to thrombus formation.30 Two recent studies have shown that larger valves have lower cavitation thresholds,24 26 which may be of importance if cavitation plays a direct or indirect role in the origin of embolic signals. A correlation was found between signal frequency and the degree of hemolysis, as expressed by the LDH level. This may be explained by a positive correlation between LDH level and valve size.28 Cavitation is one mechanism that may cause blood damage and hemolysis.27

Although there is some evidence that the incidence and frequency of cerebral embolic signals may differ with the different mechanical valve types,10 12 this was not confirmed in a recent study.13 This issue is therefore unresolved and requires the completion of studies in which an adequate number of different valve types are compared, with similar sizes and duration of valve implantation, and in which the same criteria for embolus detection are used.

In our patient population with a similar valve type, we observed a large variation in the frequency of cerebral embolic signals, ranging from 0 to more than 300 signals per hour, suggesting that there are yet unidentified additional individual factors responsible for emboli formation.31

Patients did not experience acute cerebral symptoms during TDM, even though two patients had more than 300 cerebral embolic signals per hour. This suggests that the signal size or composition is such that they do not cause obstruction of the microcirculation of the brain. Although it may seem unlikely that these signals lead to a cumulative effect on neuropsychological function, this possibility has not been excluded. A decline in cognitive function has been reported in patients with Bjørk-Shiley valves 5 years after implantation,32 but this study did not include a control population.

The incidence of stroke in this study was 1.4 per 100 patient-years, which is similar to or less than that reported previously. In a study of patients with Medtronic Hall valves, the incidence of stroke was 1.4 per 100 patient-years,33 whereas in a population with different heart valve types, the incidence was 2.6 per 100 patient-years.34

An important question is the possible prognostic significance of cerebral embolic signals in patients with prosthetic heart valves. In this study, we found that patients who had experienced TIAs, amaurosis fugax, or stroke had a higher frequency of cerebral embolic signals compared with those who had not experienced such symptoms. This association has not been found in previous studies.10 11 12 We stress that these results should be assessed with caution, since all studies to date have included only retrospective clinical data. However, the results of this study do not exclude the possibility that this examination method may provide important prognostic information for this patient group. The results strongly suggest that prospective studies should now be designed in which the aim is to determine whether the detection of cerebral embolic signals may be of help in assessing the risk of stroke in prosthetic heart valve patients.


*    Acknowledgments
 
This study was supported by The Norwegian Council on Cardiovascular Diseases.

Received November 17, 1994; revision received March 23, 1995; accepted March 27, 1995.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowSubjects and Methods
up arrowResults
up arrowDiscussion
*References
 
1. Edmunds LH. Thrombotic and bleeding complications of prosthetic heart valves. Ann Thorac Surg. 1987;44:430-445. [Abstract]

2. Karp RB, Sand ME. Mechanical prosthesis: old and new. In: Heart Valve Replacement and Reconstruction. Chicago, Ill: Year Book Medical Publisher Inc; 1987:235-253.

3. Akins CW. Mechanical cardiac valvular prostheses. Ann Thorac Surg. 1991;52:161-172. [Abstract]

4. Kuntze CEE, Ebels T, Eijgelaar A, van der Heide JNH. Rates of thromboembolism with three different mechanical heart valve prostheses: randomised study. Lancet. 1989;1:514-517. [Medline] [Order article via Infotrieve]

5. Burchfiel CM, Hammermeister KE, Krause-Steinrauf H, Sethi GK, Henderson WG, Crawford MH, Wong M. Left atrial dimension and risk of systemic embolism in patients with a prosthetic heart valve. J Am Coll Cardiol. 1990;15:32-41. [Abstract]

6. Spencer MP, Campbell SD, Sealey JL, Lindenbergh J. Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters. J Occup Med. 1969;2:238-244.

7. Russell D, Madden KP, Clark WM, Sandset PM, Zivin JA. Detection of arterial emboli using Doppler ultrasound in rabbits. Stroke. 1991;22:253-258. [Abstract/Free Full Text]

8. Russell D. The detection of cerebral emboli using Doppler ultrasound: theoretical, experimental and clinical aspects. In: Newell DW, Aaslid R, eds. Transcranial Doppler Ultrasound. New York, NY: Raven Press Publishers; 1991:207-213.

9. Spencer MP, Thomas GI, Nicholls SC, Sauvage LR. Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasound. Stroke. 1990;21:415-423. [Abstract/Free Full Text]

10. Rams JJ, Davis DA, Lolley DM, Berger MP, Spencer M. Detection of microemboli in patients with artificial heart valves using transcranial Doppler: preliminary observations. J Heart Valve Dis. 1993;2:37-41. [Medline] [Order article via Infotrieve]

11. Grosset DG, Georgiadis D, Stirling S, Cowburn P, Kelman AW, Faichney A, Lees KR. Subclinical embolism in patients undergoing cardiac valve implantation and coronary artery bypass surgery. Eur J Cardiothorac Surg. 1994;8:63-66. [Abstract]

12. Georgiadis D, Grosset DG, Kelman A, Faichney A, Lees KR. Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves. Stroke. 1994;25:587-592. [Abstract]

13. Müller HR, Burckhardt D, Casty M, Pfisterer ME, Buser MW. High intensity transcranial Doppler signals (HITS) after prosthetic valve implantation. J Heart Valve Dis. 1994;3:602-606. [Medline] [Order article via Infotrieve]

14. Ihlen H, Mølstad P, Simonsen S, Vatne K, Øvrum E, Geiran O, Laake P, Frøysaker T. Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: comparison of noninvasive and invasive techniques. Am Heart J. 1992;123:151-159. [Medline] [Order article via Infotrieve]

15. Brucher R, Russell D. The Doppler characteristics of solid and gaseous emboli. Cerebrovasc Dis. 1994;4(suppl 3):88. Abstract.

16. Schlesselman J. Case-Controlled Studies. New York, NY: Oxford University Press; 1982:203-206.

17. Altman DG. Practical Statistics for Medical Research. London, England: Chapman and Hall; 1993:286-288.

18. Altman DG. Practical Statistics for Medical Research. London, England: Chapman and Hall; 1993:336-349.

19. Siebler M, Sitzer M, Steinmetz H. Detection of intracranial emboli in patients with symptomatic carotid artery disease. Stroke. 1992;23:1652-1654. [Abstract/Free Full Text]

20. Georgiadis D, Grosset DG, Lees KR. Transhemispheric passage of microemboli in patients with unilateral internal carotid artery occlusion. Stroke. 1993;24:1664-1666. [Abstract/Free Full Text]

21. Graf T, Fischer H, Reul H, Rau G. Cavitation potential of mechanical heart valve prostheses. Int J Artif Organs. 1991;14:169-174. [Medline] [Order article via Infotrieve]

22. Lamson TC, Stinebring DR, Deutsch S, Rosenberg G, Tarbell JM. Real-time in vitro observation of cavitation in a prosthetic heart valve. ASAIO Trans. 1991;37:M351-M353. [Medline] [Order article via Infotrieve]

23. Kafesjian R, Howanec M, Ward GD, Diep L, Wagstaff LS, Rhee R. Cavitation damage of pyrolytic carbon in mechanical heart valves. J Heart Valve Dis. 1994;3(suppl 1):S2-S7.

24. Richard G, Beavan A, Strzepa P. Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses. J Heart Valve Dis. 1994;3(suppl 1):S94-S101.

25. Haubold AD, Ely JL, Chahine GL. Effect of cavitation on pyrolytic carbon in vitro. J Heart Valve Dis. 1994;3:318-323. [Medline] [Order article via Infotrieve]

26. Shu MCS, Leuer LH, Armitage TL, Schneider TE, Christiansen DR. In vitro observation of mechanical heart valve cavitation. J Heart Valve Dis. 1994;3(suppl 1):S85-S93.

27. Garrison LA, Lamson TC, Deutsch S, Geselowitz DB, Gaumond RP, Tarbell JM. An in-vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis. 1994;3(suppl 1):S8-S24.

28. Koppensteiner R, Moritz A, Schlick W, Fenzl G, Roedler S, Ehringer H, Wollner E. Blood rheology after cardiac valve replacement with mechanical prostheses or bioprostheses. Am J Cardiol. 1991;67:79-83. [Medline] [Order article via Infotrieve]

29. Turpie AGG, Gent M, Laupacis A, Latour Y, Gunstensen J, Basile F, Klimek M, Hirsh J. A comparison of aspirin with placebo in patients treated with warfarin after heart-valve replacement. N Engl J Med. 1993;329:524-529. [Abstract/Free Full Text]

30. Salzman EW, Merrill EW. Interaction of blood with artificial surfaces. In: Colman RW, Hirsh J, Marder VJ, Salzman EW, eds. Haemostasis and Thrombosis: Basic Principles and Clinical Practice. 2nd ed. Philadelphia, Pa: JB Lippincott; 1987:1335-1347.

31. Butchart EG. Thrombogenesis and anticoagulation in heart valve disease: towards a rational approach. J Heart Valve Dis. 1993;2:1-6. Editorial. [Medline] [Order article via Infotrieve]

32. Sotaniemi KA, Mononen H, Hokkanen TE. Long-term cerebral outcome after open-heart surgery: a five-year neuropsychological follow-up study. Stroke. 1986;17:410-416. [Abstract/Free Full Text]

33. Abdelnoor M, Hall KV, Nitter-Hauge S, Rostad H, Risum Ø. Morbidity in valvular heart replacement: risk factors of systemic emboli and thrombotic obstruction. Int J Artif Organs. 1988;11:303-307. [Medline] [Order article via Infotrieve]

34. Saour JN, Sieck JO, Mamo LAR, Gallus AS. Trial of different intensities of anticoagulation in patients with prosthetic heart valves. New Engl J Med. 1990;322:428-432.[Abstract]




This article has been cited by other articles:


Home page
StrokeHome page
A. King and H. S. Markus
Doppler Embolic Signals in Cerebrovascular Disease and Prediction of Stroke Risk: A Systematic Review and Meta-Analysis * Supplemental Online References
Stroke, December 1, 2009; 40(12): 3711 - 3717.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
M. Skjelland, A. Michelsen, F. Brosstad, J. L. Svennevig, R. Brucher, and D. Russell
Solid Cerebral Microemboli and Cerebrovascular Symptoms in Patients With Prosthetic Heart Valves
Stroke, April 1, 2008; 39(4): 1159 - 1164.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Guerrieri Wolf, B. P. Choudhary, Y. Abu-Omar, and D. P. Taggart
Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 512 - 520.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. Dittrich and E. B. Ringelstein
Occurrence and Clinical Impact of Microembolic Signals During or After Cardiosurgical Procedures
Stroke, February 1, 2008; 39(2): 503 - 511.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ruel, R. G. Masters, F. D. Rubens, P. J. Bedard, A. L. Pipe, W. G. Goldstein, P. J. Hendry, and T. G. Mesana
Late incidence and determinants of stroke after aortic and mitral valve replacement
Ann. Thorac. Surg., July 1, 2004; 78(1): 77 - 83.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
V. Dalinin, P. S. Lingaas, K. Hatteland, and J. L Svennevig
Carotid Doppler microembolic signals in patients one year after heart valve surgery
Perfusion, December 1, 2003; 18(6): 333 - 337.
[Abstract] [PDF]


Home page
StrokeHome page
R. Brucher and D. Russell
Automatic Online Embolus Detection and Artifact Rejection With the First Multifrequency Transcranial Doppler
Stroke, August 1, 2002; 33(8): 1969 - 1974.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. Russell and R. Brucher
Online Automatic Discrimination Between Solid and Gaseous Cerebral Microemboli With the First Multifrequency Transcranial Doppler
Stroke, August 1, 2002; 33(8): 1975 - 1980.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. Georgiadis, S. Braun, F. Uhlmann, G. M. Bernacca, W. J. Schulte-Mattler, S. Zierz, and H. R. Zerkowski
Doppler microembolic signals in patients with two different types of bileaflet valves
J. Thorac. Cardiovasc. Surg., June 1, 2001; 121(6): 1101 - 1116.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
C. R. Wilhelm, J. Ristich, L. E. Knepper, R. Holubkov, S. R. Wisniewski, R. L. Kormos, and W. R. Wagner
Measurement of Hemostatic Indexes in Conjunction With Transcranial Doppler Sonography in Patients With Ventricular Assist Devices
Stroke, December 1, 1999; 30(12): 2554 - 2561.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Deklunder, M. Roussel, J.-L. Lecroart, A. Prat, and C. Gautier
Microemboli in Cerebral Circulation and Alteration of Cognitive Abilities in Patients With Mechanical Prosthetic Heart Valves
Stroke, September 1, 1998; 29(9): 1821 - 1826.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. Georgiadis, R. W. Baumgartner, R. Karatschai, A. Lindner, and H. R. Zerkowski
Further evidence of gaseous embolic material in patients with artificial heart valves
J. Thorac. Cardiovasc. Surg., April 1, 1998; 115(4): 808 - 810.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
E. Bernd Ringelstein, D. W. Droste, V. L. Babikian, D. H. Evans, D. G. Grosset, M. Kaps, H. S. Markus, D. Russell, and M. Siebler
Consensus on Microembolus Detection by TCD
Stroke, March 1, 1998; 29(3): 725 - 729.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
U. Sliwka and D. Georgiadis
Clinical Correlations of Doppler Microembolic Signals in Patients With Prosthetic Cardiac Valves : Analysis of 580 Cases
Stroke, January 1, 1998; 29(1): 140 - 143.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. W. Droste, T. Hansberg, V. Kemeny, D. Hammel, G. Schulte-Altedorneburg, D. G. Nabavi, M. Kaps, H. H. Scheld, and E. B. Ringelstein
Oxygen Inhalation Can Differentiate Gaseous From Nongaseous Microemboli Detected by Transcranial Doppler Ultrasound
Stroke, December 1, 1997; 28(12): 2453 - 2456.
[Abstract] [Full Text]


Home page
StrokeHome page
D. Georgiadis, A. Wenzel, D. Lehmann, A. Lindner, H.R. Zerkowski, S. Zierz, and M.P. Spencer
Influence of Oxygen Ventilation on Doppler Microemboli Signals in Patients With Artificial Heart Valves
Stroke, November 1, 1997; 28(11): 2189 - 2194.
[Abstract] [Full Text]


Home page
CirculationHome page
A. Notzold, D. W. Droste, G. Hagedorn, S. Berndt, M. Kaps, B. Graf, and H. H. Sievers
Circulating Microemboli in Patients After Aortic Valve Replacement With Pulmonary Autografts and Mechanical Valve Prostheses
Circulation, September 16, 1997; 96(6): 1843 - 1846.
[Abstract] [Full Text]


Home page
StrokeHome page
V. L. Babikian, C. A. C. Wijman, C. Hyde, N. L. Cantelmo, M. R. Winter, E. Baker, and V. Pochay
Cerebral Microembolism and Early Recurrent Cerebral or Retinal Ischemic Events
Stroke, July 1, 1997; 28(7): 1314 - 1318.
[Abstract] [Full Text]


Home page
StrokeHome page
D. Georgiadis, M. Preiss, A. Lindner, Y. Gybels, S. Zierz, and H. R. Zerkowski
Doppler Microembolic Signals in Children With Prosthetic Cardiac Valves
Stroke, July 1, 1997; 28(7): 1328 - 1329.
[Abstract] [Full Text]


Home page
StrokeHome page
D. Georgiadis, A. Lindner, M. Manz, M. Sonntag, P. Zunker, H. R. Zerkowski, and M. Borggrefe
Intracranial Microembolic Signals in 500 Patients With Potential Cardiac or Carotid Embolic Source and in Normal Controls
Stroke, June 1, 1997; 28(6): 1203 - 1207.
[Abstract] [Full Text]


Home page
StrokeHome page
H. S. Markus and J. Molloy
Use of a Decibel Threshold in Detecting Doppler Embolic Signals
Stroke, April 1, 1997; 28(4): 692 - 695.
[Abstract] [Full Text]


Home page
StrokeHome page
D. W. Droste, G. Hagedorn, A. Notzold, H.-J. Siemens, H. H. Sievers, and M. Kaps
Bigated Transcranial Doppler for the Detection of Clinically Silent Circulating Emboli in Normal Persons and Patients With Prosthetic Cardiac Valves
Stroke, March 1, 1997; 28(3): 588 - 592.
[Abstract] [Full Text]


Home page
StrokeHome page
M. Kaps, J. Hansen, M. Weiher, K. Tiffert, I. Kayser, and D. W. Droste
Clinically Silent Microemboli in Patients With Artificial Prosthetic Aortic Valves Are Predominantly Gaseous and Not Solid
Stroke, February 1, 1997; 28(2): 322 - 325.
[Abstract] [Full Text]


Home page
StrokeHome page
M. Daffertshofer, S. Ries, U. Schminke, and M. Hennerici
High-Intensity Transient Signals in Patients With Cerebral Ischemia
Stroke, October 1, 1996; 27(10): 1844 - 1849.
[Abstract] [Full Text]


Home page
StrokeHome page
A.M. Forteza, V.L. Babikian, C. Hyde, M. Winter, and V. Pochay
Effect of Time and Cerebrovascular Symptoms on the Prevalence of Microembolic Signals in Patients With Cervical Carotid Stenosis
Stroke, April 1, 1996; 27(4): 687 - 690.
[Abstract] [Full Text]


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brækken, S. K.
Right arrow Articles by Svennevig, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brækken, S. K.
Right arrow Articles by Svennevig, J.