(Stroke. 2000;31:2189.)
© 2000 American Heart Association, Inc.
Original Contributions |
From the Department of Vascular Surgery, Irvine Laboratory for Cardiovascular Investigation and Research (M.M.S., T.J.T., A.N.N., S.D., G.J.P.), and Department of Radiology (J.M.S.), Imperial College School of Medicine at St Marys Hospital, London, UK.
Correspondence to Michael M. Sabetai, MD, Irvine Laboratory for Cardiovascular Investigation and Research, Imperial College School of Medicine at St Marys Hospital, Department of Vascular Surgery, 10th Floor, QEQM Wing, London W2 1NY, UK. E-mail mmsabetai{at}hotmail.com
| Abstract |
|---|
|
|
|---|
MethodsCarotid plaques were scanned with the use of ultrasound, and their images were stored in a computer. They were normalized by assigning certain gray values to blood and adventitia, and the gray scale median (GSM) was used to quantify their echogenicity. The variability between storage media, between degrees of magnification, and between probes was assessed. The method was applied to 232 asymptomatic carotid plaques causing 60% to 99% stenosis in relation to the presence of ipsilateral CT-demonstrated brain infarcts. In all parts of the study the plaque GSM was measured before and after normalization to evaluate its effect. Interobserver agreement for the scanning process was assessed.
ResultsThe GSM mean difference before and after normalization for variability studies of storage media, degrees of magnification, and probes was -14.5 and -0.12, 2.24 and 1.68, and -8.3 and -0.7, respectively. The median GSM of plaques associated with ipsilateral nonlacunar silent CT-demonstrated brain infarcts was 14, and that of plaques that were not so associated was 30 (P=0.003). The interobserver GSM difference was -0.05 (95% CI, -1.7 to 1.6).
ConclusionsOur method decreases the variability between storage media and between probes but not the variability between degrees of magnification. It separates echomorphologically the carotid plaques associated with silent nonlacunar CT-demonstrated brain infarcts from plaques that are not so associated.
Key Words: carotid stenosis echogenicity reproducibility ultrasonography
| Introduction |
|---|
|
|
|---|
Initial reproducibility studies performed by our group have shown good interobserver reproducibility in normalizing carotid plaque B-mode images (4 observers normalized images obtained using 2 different scanners)13 and improved comparability of carotid plaque echogenicity after normalization when different gains and different scanners were used.15
The aim of the first part of this study was to assess the effect of B-mode image normalization on the comparability of carotid plaque echogenicity when the following were used: (1) 2 of the most commonly used storage media (super-VHS videotape and magneto-optical disk [MOD]); (2) 2 different degrees of magnification (zoom and high-definition zoom [HD zoom]); and (3) 2 different linear array probes (7 and 10 MHz).
The interobserver agreement in scanning a carotid plaque, resulting in an image suitable for normalization by following specific criteria, and the intraobserver agreement for normalizing images were evaluated.
The aim of the second part of the study was to examine the effect of B-mode image normalization on a possible association between carotid plaque computer-quantified echogenicity and the presence of ipsilateral nonlacunar silent CT-demonstrated brain infarcts in patients with significant asymptomatic carotid stenosis.
| Subjects and Methods |
|---|
|
|
|---|
In the second part of the study, 186 patients (117 men and 69 women) with 232 asymptomatic carotid plaques causing 60% to 99% stenosis were studied with duplex scanning. The 60% cutoff point as an inclusion criterion was based on the results of the Asymptomatic Carotid Atherosclerosis Study (ACAS).16 In each patient the presence of such a plaque defined the side of interest (unit of the study). These patients were referred to our vascular laboratory for the evaluation of carotid stenosis in the presence of peripheral vascular disease, coronary artery disease, carotid bruit, or relevant risk factors. Patients with atrial fibrillation, valvular lesions, recent myocardial infarction, or severe congestive heart failure were excluded to eliminate cardioembolism as the cause of the cerebrovascular pathology. The cardiac diagnosis was based on clinical and ECG findings alone. No transcutaneous or transesophageal echocardiography was performed. All patients were examined by a neurologist (T.J.T.) and underwent a brain CT scan, which was reported by an independent neuroradiologist (J.M.S.).
Grading of Carotid Stenosis
The degree of stenosis was calculated according to
criteria established at an international consensus meeting on grading
carotid stenosis.17 We measured the peak
systolic velocity of the internal carotid artery18
and the ratio of the peak systolic velocity of the internal
carotid artery to that of the common carotid artery,19 20
which has been validated by others. The ratio of the peak
systolic velocity of the internal carotid artery to the
end-diastolic velocity of the common carotid
artery21 22 has been validated in our vascular laboratory
with angiographic stenosis in relation to the distal internal
carotid artery23 24 and applied
previously.13 14 15
Carotid Duplex Settings
According to the recommendations of the international consensus
concerning ultrasonic morphology and the stroke risk of carotid
plaques,25 the choice of equipment, settings, and
interobserver reproducibility should be considered.
Ultrasound scanning was performed with the ATL HDI 3000 scanner (Advanced Technologies Laboratories), and the following settings were selected: (1) maximum dynamic range (60 dB); (2) a 7-MHz linear array multifrequency probe (for the probes reproducibility study, the 7- and 10-MHz linear array probes were used); (3) gain setting was not set so high that the structural details of the far wall media-adventitia interface were concealed by introducing a great deal of noise in the vessel lumen (blood) and was not set so low that the far wall intima-media interface could not be easily identifiable. This also ensured the availability of the 2 reference structures for image normalization: noiseless vessel lumen and an echo-dense area of adventitia in the vicinity of the plaque; (4) time gain compensation curve gently sloping but vertical through the lumen of the vessel. This ensured similar average gray scale levels of the tissues lying superficial and deep in relation to the artery and areas of anterior and posterior wall adventitia of nearly identical gray scale levels. The latter is essential for normalization of carotid plaque images with anterior and posterior components.
In addition, a linear postprocessing curve was selected because image normalization is achieved with linear scaling.
Carotid Plaque Recording Protocol
With the patient in the supine position, the carotid bifurcation
was imaged in longitudinal (anterolateral, lateral, and posterolateral)
and transverse projections. The transducer was kept parallel to the
vessel so that the near and far wall adventitia was imaged at right
angles. The aim was to obtain a carotid plaque B-mode image with a
relatively noiseless vessel lumen, with an echo-dense area of
adventitia in the vicinity of the plaque and with an echoically
informative plaque that can be outlined easily. The projection that
fulfilled these criteria was chosen. In the case of
heterogeneous plaques (ie, those containing hypoechoic and
hyperechoic areas), the projection that fulfilled the above
criteria and provided the highest echogenicity was selected. Plaques
included in an acoustic shadow were analyzed only if >50% of
their area depicted real acoustic information, and only this area was
subjected to analysis (the number of pixels in the area of
interest was at least half of the total number of pixels in the area of
the plaque, as calculated by the Adobe Photoshop software). Plaques for
which we did not have any B-mode information because of acoustic
shadowing were excluded from the study.
In the storage media reproducibility study, the most echoically informative longitudinal projection of the plaque was stored on videotape (Konica sVHS) and simultaneously digitized onto a MOD. The corresponding color Doppler plaque image was recorded on videotape and stored onto a MOD to assist with the off-line delineation of the luminal plaque border. During the same scanning session, the same image was magnified x1 and then x3 with the HD zoom facility of the scanner. Both images were directly digitized onto a MOD. The corresponding color Doppler image was also digitized and stored onto a MOD. In the probes reproducibility study, the carotid plaque was imaged through the same longitudinal projection with the 2 linear array probes (7 and 10 MHz), and the B-mode and corresponding color Doppler images were directly digitized onto a MOD. All scans were done by 1 experienced operator (T.J.T.).
In the second part of the study, the aforementioned duplex settings and carotid plaque recording protocol were followed. All scans were performed by 2 experienced operators (T.J.T., S.D.) using the 7-MHz linear array probe and adjusting the gain and the degree of magnification according to their perception of the optimum image. Carotid plaque images were stored on super-VHS videotape and subsequently digitized to a personal computer with the use of a commercially available video grabber card or directly stored onto a MOD in digital form.
B-Mode Image Normalization
This method has been previously described.13 In
brief, B-mode images are digitized and transferred to a personal
computer. With the use of the software Adobe Photoshop (version 3.0 or
later) and the "histogram" facility, the gray scale median (GSM) of
the 2 reference points (blood and adventitia) in the original B-mode
image is defined. Algebraic (linear) scaling of the image is performed
with the "curves" option of the software so that in the resultant
image the GSM of blood equals 0 to 5 and that of the adventitia equals
185 to 195. In this way, the gray scale values of all the pixels in the
image are adjusted according to the input and output values of the 2
reference points (blood: input value=measured GSM before linear
scaling; output value=0 to 5; adventitia: input value=measured GSM
before linear scaling; output value=185 to 195) (Figure 1
). The GSM of the plaque (the median of
the frequency distribution of the gray levels of the pixels in the
plaque) in the normalized image (adjusted image using linear scaling)
is used to quantify its echogenicity (Figure 2
).
|
|
CT-Demonstrated Brain Infarct Classification
Upon recruitment of the patients into the study, a CT brain scan
was performed, and the presence of ischemic lesions in the
middle and anterior cerebral artery territory was noted.
Intracerebral hemorrhages and posterior
circulation infarcts as well as ischemic lesions in sides with
carotid bifurcation plaques causing <60% stenosis were not
considered in this analysis.
The appropriate sides with CT-demonstrated brain infarctions were classified into group A (nonlacunar CT-demonstrated infarctions, cardioembolism excluded, mainly related to extracranial carotid atheroembolism),26 27 28 29 30 group B (lacunar CT-demonstrated infarctions and diffuse white matter low density changes, related to cerebral small-vessel disease),30 31 32 33 and normal CT scan. When both nonlacunar and lacunar CT-demonstrated brain lesions were present, the infarcts were classified as nonlacunar lesions.34 All CT brain scans were reported by an experienced neuroradiologist (J.M.S.) who was unaware of patients clinical characteristics.
Interobserver and Intraobserver Agreement
The application of the aforementioned settings should result in
the optimum B-mode image for normalization, ie, one with a relatively
noiseless vessel lumen, with an echo-dense area of adventitia in the
vicinity of the plaque, and with an echoically informative plaque that
can easily be outlined.
Fifty-two consecutive patients with 52 asymptomatic carotid bifurcation plaques were scanned during the same scanning session by 2 operators (S.D., M.M.S.) with varying degrees of experience. The 2 operators were unaware of each others carotid plaque scanning and the images obtained. Both were instructed to follow the carotid plaque scanning protocol described previously. B-mode and color Doppler images were stored onto a MOD and normalized off-line by 1 operator (M.M.S.) at a later time. In addition, 26 of the 52 B-mode images were normalized at 2 different times within a 6-month period by 1 operator (M.M.S.). The interobserver limits of agreement for following the carotid plaque scanning protocol and the intraobserver limits of agreement for normalizing images were evaluated according to the method proposed by Bland and Altman.35
Statistical Analysis
The distribution of all variables was tested for normality
with the Levene test for the homogeneity of variances. Normally
distributed variables were expressed as mean and 95% CIs. To test
whether the mean GSM differences were the same before and after image
normalization, the paired-samples t test was used. The
median and interquartile range (IQR) were used to describe the
nonnormally distributed variables. The nonparametric
Wilcoxon Mann-Whitney test was used to compare the
distributions between these variables.
To assess interobserver variability, the average of the paired measurements was plotted against their difference to examine whether the differences change in proportion to the corresponding average values. If the differences are relatively constant and normally distributed, 95% of these differences will lie between ±2 SD of the mean difference.35 This range will be referred as the interobserver "limits of agreement." The frequency distribution of the average of the paired measurements of the GSM for each plaque was divided in quartiles, and the interobserver limits of agreement for each quartile were assessed.
To test the hypothesis that plaque echogenicity and/or the degree of
stenosis (predictor variables) can predict the presence of
nonlacunar or lacunar ipsilateral silent CT-demonstrated brain infarcts
(dependent variable), logistic regression analysis was
used. These calculations were performed with the statistical package
SPSS for Windows (version 9.0). P values of
0.05 were
considered statistically significant.
| Results |
|---|
|
|
|---|
|
The prevalence of silent CT-demonstrated brain infarcts in group A was
27 of 232 (11.6%), and that in group B and the normal CT group was 205
of 232 (88.4%). In group A, CT-demonstrated brain infarcts were
identified in 6 of 46 patients (13%) with bilateral
asymptomatic carotid stenosis (8/92 sides of
interest). No hemorrhagic or watershed infarcts were identified in the
hemispheres of interest in this group of patients. The median (IQR) GSM
of plaques associated with (1) group A CT-demonstrated infarcts and (2)
group B and normal CT scans before normalization was 11 (1 to 33) and
21 (9.5 to 32) (P=0.165) and after normalization was 14 (0
to 26) and 30 (14 to 49), respectively (P=0.003,
Wilcoxon Mann-Whitney test). Figure 3
illustrates the corresponding box and
whiskers plots. The median (IQR) degree of stenosis of those
associated with (1) group A CT-demonstrated infarcts and (2) group B
and normal CT scans was 80% (65% to 90%) in both groups
(P=0.61, Wilcoxon Mann-Whitney test). Logistic
regression analysis revealed that plaque echogenicity after
image normalization (P=0.008) and not the degree of
stenosis (P=0.82) predicted the presence of group A
CT-demonstrated brain infarcts as contrasted with the presence of group
B and normal CT scans.
|
The mean GSM of the plaques entered into the interobserver and
intraobserver reproducibility study was 26 (range, 0 to 79) and 16
(range, 0 to 54), respectively, which is a
representative sample ranging from hypoechoic to
hyperechoic plaques. Table 2
shows the
interobserver mean difference (95% CI) and the limits of agreement for
the full range and each quartile of average GSM. The intraobserver mean
difference was 1.7 (-0.5 to 3.8) and the limits of agreement ±10.2.
Figure 4
shows the scatterplot of the
mean GSM against the GSM difference for each plaque between the 2
observers. The limits of agreement are defined.
|
|
| Discussion |
|---|
|
|
|---|
Although there is agreement by most investigators regarding use of the vessel lumen as the reference structure for hypoechogenicity, there is no consensus on which one should be used for hyperechogenicity. The consensus report has suggested use of the mastoid muscle and the body of the cervical vertebra for isoechogenicity and hyperechogenicity, respectively.25 In agreement with others,11 41 we believe that the 2 reference structures should be the vessel lumen for hypoechogenicity and the adjacent adventitia for hyperechogenicity. They are close to the plaque and thus easier to be included in the same projection with the most echoically informative plaque and probably prone to lower interobserver variability. In addition, linear scaling is achieved between 2 points (the GSM of the 2 reference echo structures).
The Tromsø Study41 reported good intraobserver and
interobserver (2 observers) agreement (
=0.73 and
=0.69,
respectively) based on the Gray-Weale classification (type 1 to type 4
plaques, where type 1 denotes low and type 4 high echogenicity). They
used 2 reference structures (vessel lumen and adventitia) and concluded
that standardization of plaque echogenicity against well-defined
reference structures is very important since lack of such structures is
the major source of error. Two other studies reported good
interobserver agreement (
=0.79 and
=0.61,
respectively),7 42 although they are not directly
comparable because they used different classifications, they did not
use reference structures to compare plaque echogenicity, and 1 of them
is based on B-mode images only.7
The study by deBray et al9 reported the interobserver (9
observers) agreement on carotid plaque echogenicity for images
collected in 4 different centers. They used the classification proposed
by Geroulakos et al7 and 2 reference structures: the
vessel lumen for hypoechogenicity and the intima-media complex for
isoechogenicity. They reported fair interobserver agreement
(
=0.31±0.14) due to inadequate reference structure for
hyperechogenicity and the subjective assessment of carotid plaque
echogenicity. Similar results were obtained by Montauban van Swijndregt
et al11 (
=0.38) using a modified
Gray-Weale classification and the vessel lumen and adjacent adventitia
as the echo structures of reference.
Arnold et al,10 using the 4-category Gray-Weale classification, reported fair to moderate interobserver (4 observers) agreement with fair agreement for the images stored in digital form and moderate for those stored on a hard copy (printed on paper). When the 2-category classification (homogeneous or heterogeneous) proposed by Reilly et al3 was used, the agreement was moderate to good. The reference structures used were the vessel lumen and the adjacent adventitia or soft tissues. Furthermore, in a different study from the same group, it was reported that carotid plaques appearing hypoechoic using a transcutaneous 7-MHz probe may appear hyperechoic when they are scanned intraoperatively with a 10-MHz probe.43 They concluded that the difficulty in reproducing high levels of agreement previously published was due to the different and subjective classifications that exist, the variability in the storage and display media used, the variability in the image quality, and the statistics used.
In our study we have shown that the significant difference that exists in plaque echogenicity when the images are stored in super-VHS and MOD is eliminated after image normalization. B-mode images stored on videotape are subjected to compression and appear darker when reviewed off-line. This is more pronounced for images printed on paper.10 On the other hand, those stored on MOD, because they are not transformed from digital into another form, undergo the least possible compression and have the best achievable resolution, thus appearing brighter.
Significant differences in ultrasonic plaque character exist when different linear array probes are used, as shown in our study and studies by others.43 The better spatial resolution achieved when a higher-frequency probe is used, especially when superficial structures are scanned (such as carotid plaques), results in an image with lower contrast but more gray scale information. This may introduce significant variability in the assessment of plaque echogenicity, which is eliminated with B-mode image normalization because of the adjustment of contrast and brightness to predetermined GSM values of the reference echo structures.
Plaque echogenicity was the same before and after image normalization when 2 degrees of magnification (including HD zoom) were used. Excessive magnification (not used in this reproducibility study) may reduce the possibility of having available an echodense area of adventitia near the plaque and should be avoided.
Quantification by means of GSM allows us to use simple statistics to assess variability and to define easily the limits of experimental error. Additionally, we have shown that the carotid plaque recording protocol, which leads to images suitable for normalization, can be followed with high interobserver agreement. These findings may have significant implications in (1) reducing the variability of plaque characterization and (2) quantifying true changes (those outside the limits of experimental error) of plaque echogenicity in prospective multicenter studies.
The clinical usefulness of the method is shown in the association between asymptomatic carotid plaque echogenicity and the presence of nonlacunar CT-demonstrated brain infarcts, which becomes apparent only after image normalization. Although earlier studies by our group44 and others40 have shown an association between hypoechoic plaques by means of low GSM and CT-demonstrated brain infarcts, their results were based on a mixed group of symptomatic and asymptomatic plaques, the types of infarcts were not clearly defined, and the mean GSM values varied significantly because no normalization of B-mode images was applied.
The prevalence of 11.6% of nonlacunar silent CT-demonstrated brain infarcts in our study is similar to that reported by the ACAS trial (13%),16 although 2 other studies have reported a prevalence of 19% and 28%.45 46 The comparison is difficult, however, because of lack of uniformity in the classification of CT-demonstrated brain infarcts.
Hypoechoic plaques have been associated with the development of neurological events in several studies of asymptomatic carotid stenosis,4 8 47 48 49 systemic risk factors for atherosclerosis,39 42 and a tendency for higher embolic counts on transcranial Doppler.50 In addition, increased embolic counts on transcranial Doppler have been associated with a higher prevalence of nonlacunar CT-demonstrated brain infarcts.50 Because of the association of asymptomatic hypoechoic plaques with nonlacunar silent CT-demonstrated brain infarcts shown in this study, it is tempting to implicate carotid atheroembolism as the pathogenetic factor for these types of infarcts. On the other hand, although the presence of CT-demonstrated brain infarcts may predict the development of ischemic stroke in patients presenting with transient ischemic attacks51 52 and is associated with significantly worse prognosis after carotid endarterectomy,34 53 54 their role as a risk factor for atheroembolic stroke in patients with asymptomatic carotid stenosis is not certain and remains to be proven.
The limitations of our study were the lack of vascular imaging to detect carotid siphon or middle cerebral artery stenosis and the lack of assessment of the cerebral collateral circulation by means of transcranial Doppler. In addition, cardioembolism was excluded on the basis of medical history and electrocardiography alone.
In conclusion, we have shown that (1) it is possible to quantify carotid plaque echogenicity and to overcome the subjectivity of the existing classifications by using a simple computer-assisted method, (2) this method decreases the variability introduced when different storage media and different linear array probes are used, and (3) asymptomatic hypoechoic carotid plaques are associated with particular types of silent CT-demonstrated brain infarcts, possibly through an atheroembolic mechanism, in a cross-sectional study. This method can be applied in prospective clinical studies that seek to assess the association of carotid plaque echogenicity with other established risk factors for atherosclerosis and ischemic stroke.2
| Acknowledgments |
|---|
Received April 6, 2000; revision received May 16, 2000; accepted June 13, 2000.
| References |
|---|
|
|
|---|
2. Nicolaides AN. Asymptomatic carotid stenosis and risk of stroke: identification of a high risk group (ACSRS). Int Angiol. 1995;14:2123.[Medline] [Order article via Infotrieve]
3. Reilly LM, Lusby RJ, Hughes L, Ferrell LD, Stoney RJ, Ehrenfeld WK. Carotid plaque histology using real-time ultrasonography: clinical and therapeutic implications. Am J Surg. 1983;146:188193.[Medline] [Order article via Infotrieve]
4.
Johnson JM, Kennelly MM, Decesare D, Morgan S, Sparrow
A. Natural history of asymptomatic carotid plaque.
Arch Surg. 1985;120:10101012.
5. Gray-Weale AC, Graham JC, Burnett JR, Byrne K, Lusby RJ. Carotid artery atheroma: comparison of preoperative B-mode ultrasound appearance with carotid endarterectomy specimen pathology. J Cardiovasc Surg. 1988;29:676681.[Medline] [Order article via Infotrieve]
6. Widder B, Paulat K, Hachpacher J, Hamann H, Hutschenreiter S, Kreutzer C, Ott F, Vollmar J. Morphological characterisation of carotid artery stenoses by ultrasound duplex scanning. Ultrasound Med Biol. 1990;16:349354.[Medline] [Order article via Infotrieve]
7. Geroulakos G, Ramaswami G, Nicolaides A, James K, Labropoulos N, Belcaro G, Holloway M. Characterisation of symptomatic and asymptomatic carotid plaques using high-resolution real-time ultrasonography. Br J Surg. 1993;80:12741277.[Medline] [Order article via Infotrieve]
8.
Polak JF, Shemanski L, OLeary DH, Lefkowitz D, Price
TR, Savage PJ, Brant WE, Reid C, for the Cardiovascular
Health Study. Hypoechoic plaque at ultrasound of the carotid artery: an
independent risk factor in adults aged 65 years or older.
Radiology. 1998;208:649654.
9. deBray JM, Baud JM, Delanoy P, Camuzat JP, Dehans V, Descamp-Le Chevoir J, et al. Reproducibility in ultrasonic characterization of carotid plaques. Cerebrovasc Dis. 1998;8:273277.[Medline] [Order article via Infotrieve]
10.
Arnold JAC, Modaresi KB, Thomas N, Taylor PR,
Padayachee TS. Carotid plaque characterization by duplex scanning:
observer error may undermine current clinical trials.
Stroke. 1999;30:6165.
11. Montauban van Swijndregt AD, Elbers HRJ, Moll FL, de Letter J, Ackerstaff RGA. Ultrasonographic characterisation of carotid plaques. Ultrasound Med Biol. 1998;24:489493.[Medline] [Order article via Infotrieve]
12.
Grønholdt MLM. Ultrasound and lipoproteins as
predictors of lipid-rich, rupture-prone plaques in the carotid artery.
Arterioscler Thromb Vasc Biol. 1999;19:213.
13. El-Atrozy T, Nicolaides A, Tegos T, Zarka AZ, Griffin M, Sabetai M. The effect of B-mode image standardisation on the echodensity of symptomatic and asymptomatic carotid bifurcation plaques. Int Angiol. 1998;17:179186.[Medline] [Order article via Infotrieve]
14. Sabetai MM, Tegos TJ, Nicolaides AN, El-Atrozy TS, Dhanjil S, Griffin M, Belcaro G, Geroulakos G. Hemispheric symptoms and carotid plaque echomorphology. J Vasc Surg. 2000;31:3949.[Medline] [Order article via Infotrieve]
15. Tegos TJ, Sabetai MM, Nicolaides AN, Pare GJ, El-Atrozy TS, Dhanjil S, Griffin M. Comparability of the ultrasonic tissue characteristics of carotid plaques. J Ultrasound Med. 2000;19:399407.[Abstract]
16.
Asymptomatic Carotid
Atherosclerosis Study Group. Carotid
endarterectomy for patients with
asymptomatic internal carotid artery stenosis.
JAMA. 1995;273:14211428.
17. deBray JM, Glatt B. Quantification of atheromatous stenosis in the extracranial carotid artery. Cerebrovasc Dis. 1995;5:414426.
18.
Polak JF, Dopkin GR, OLeary DH, Wang AM, Cutler SS.
Internal carotid artery stenosis: accuracy and reproducibility
of color-Doppler assisted duplex imaging. Radiology. 1989;173:793800.
19. Moneta GL, Edwards JM, Chitwood RW, Taylor LM, Lee RW, Cummings CA, Porter JM. Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70% to 90% internal carotid artery stenosis with duplex scanning. J Vasc Surg. 1993;17:152159.[Medline] [Order article via Infotrieve]
20. Moneta GL, Edwards JM, Papanicolaou G, Hatsukami T, Taylor LM Jr, Strandness ED Jr, Porter JM. Screening for asymptomatic internal carotid artery stenosis: duplex criteria for discriminating 60% to 99% stenosis. J Vasc Surg. 1995;21:989994.[Medline] [Order article via Infotrieve]
21. Breslau PJ. Ultrasonic Duplex Scanning in the Evaluation of Carotid Artery Disease [medical thesis]. Maastricht, Netherlands: University of Maastricht; 1981.
22. Knox RA, Breslau PJ, Strandness DE. A simple parameter for accurate detection of severe carotid stenosis. Br J Surg. 1982;69:230233.[Medline] [Order article via Infotrieve]
23. Nicolaides AN, Shifrin EG, Bradbury A, Dhanjil S, Griffin M, Belcaro G, Williams M. Angiographic and duplex grading of internal carotid stenosis: can we overcome the confusion? J Endovasc Surg. 1996;3:158165.[Medline] [Order article via Infotrieve]
24. Dhanjil S, Jameel M, Nicolaides AN, Belcaro G, Williams M, Griffin M, Ramaswami G. Ratio of peak systolic velocity of internal carotid to end diastolic velocity of common carotid: new duplex criteria for grading internal carotid stenosis. J Vasc Technol. 1997;21:237240.
25. deBray JM, Baud JM, Dauzat M, for the Consensus Conference. Consensus concerning the morphology and the risk of carotid plaques. Cerebrovasc Dis. 1997;7:289296.
26. Stevens JM, Barber CJ, Kerslake R, Broz M, Barter S. Extended use of cranial CT in the evaluation of patients with stroke and transient ischaemic attacks. Neuroradiology. 1991;33:200206.[Medline] [Order article via Infotrieve]
27.
Norrving B, Cronqvist S. Clinical and radiologic
features of lacunar versus nonlacunar minor stroke. Stroke. 1989;20:5964.
28.
Bogousslavsky J, Regli F. Centrum ovale infarcts:
subcortical infarction in the superficial territory of the middle
cerebral artery. Neurology. 1992;42:19921998.
29.
Weiller C, Ringelstein B, Reiche W, Thron A, Buell U.
The large striatocapsular infarctions: a clinical and
pathophysiological entity. Arch Neurol. 1990;47:10851091.
30.
Bogousslavsky J. The plurality of subcortical
infarction. Stroke. 1992;23:629631.
31.
Hachinski VC, Potter P, Merksey H. Leuko-araiosis.
Arch Neurol.. 1987;44:2123.
32.
Pantoni L, Garcia JH. Pathogenesis of leukoaraiosis.
Stroke. 1997;28:652659.
33.
Caplan L, Babikian V, Helgason C, Hier DB, DeWitt D,
Patel D, Stein R. Occlusive disease of the middle cerebral artery.
Neurology. 1985;35:975982.
34. Cao P, Zannetti S, Giordano G, De Rango P, Parlani G, Caputo N. Cerebral tomographic findings in patients undergoing carotid endarterectomy for asymptomatic carotid stenosis: short-term and long-term implications. J Vasc Surg. 1999;29:9951005.[Medline] [Order article via Infotrieve]
35. Bland M, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet. 1986;1:307310.[Medline] [Order article via Infotrieve]
36.
Skorton DJ, Melton HE Jr, Pandian NG, Nichols J,
Koyanagi S, Marcus ML, Collins SM, Kerber RE. Detection of acute
myocardial infarction in closed-chest dogs by analysis of
regional two-dimensional echocardiographic gray-level
distributions. Circ Res. 1983;52:3644.
37.
Picano E, Landini L, Lattanzi F, Mazzarisi A, Sarnelli
R, Distante A, Benassi A, LAbbate A. The use of frequency histograms
of ultrasonic backscatter amplitudes for detection of
atherosclerosis in vitro. Circulation. 1986;74:10931098.
38. El-Barghouty NM, Geroulakos G, Nicolaides A, Androulakis A, Bahal V. Computer-assisted carotid plaque characterisation. Eur J Vasc Surg. 1995;9:389393.
39.
Grønholdt MLM, Nordestgaard BG, Wiebe BM, Wilhjelm JE,
Sillesen H. Echo-lucency of computerized ultrasound images of carotid
atherosclerotic plaques are associated with increased levels of
triglyceride-rich lipoproteins as well as increased plaque
lipid content. Circulation. 1998;97:3440.
40. Biasi GM, Sampaolo A, Mingazzini P, DeAmicis P, El-Barghouty NM, Nicolaides AN. Computer analysis of ultrasonic plaque echolucency in identifying high-risk carotid bifurcation lesions. Eur J Vasc Endovasc Surg. 1999;17:476479.[Medline] [Order article via Infotrieve]
41.
Joakimsen O, Bønaa KH, Stensland-Bugge E.
Reproducibility and ultrasound assessment of carotid plaque occurrence,
thickness, and morphology: the Tromsø Study. Stroke. 1997;28:22012207.
42.
Grønholdt MLM, Nordestgaard B, Nielsen TG, Sillesen H.
Echolucent carotid artery plaques are associated with elevated levels
of fasting and postprandial triglyceride-rich lipoproteins.
Stroke. 1996;27:21662172.
43. Padayachee TS, Modaresi KB, McGuiness C, Taylor PR. The carotid bifurcation: transcutaneous versus intraoperative duplex assessment. Br J Surg. 1999;86(suppl 1):49. Abstract.
44. El-Barghouty NM, Nicolaides A, Bahal V, Geroulakos G, Androulakis A. The identification of the high risk carotid plaque. Eur J Vasc Surg. 1996;11:470478.
45.
Norris JW, Zhu CZ. Silent stroke and carotid
stenosis. Stroke. 1992;23:483485.
46. Grigg MJ, Papadakis K, Nicolaides AN, Al-Kutoubi A, Williams MA, Deacon DFS, Sonecha T, Eastcott HHG. The significance of cerebral infarction and atrophy in patients with amaurosis fugax and transient ischemic attacks in relation to internal carotid artery stenosis: a preliminary report. J Vasc Surg. 1988;7:215222.[Medline] [Order article via Infotrieve]
47. OHolleran LW, Kennelly MM, McClurken M, Johnson JM. Natural history of asymptomatic carotid plaque. Am J Surg. 1987;154:659661.[Medline] [Order article via Infotrieve]
48. Langsfeld M, Gray-Weale AC, Lusby RJ. The role of plaque morphology and diameter reduction in the development of new symptoms in asymptomatic carotid arteries. J Vasc Surg. 1989;9:548557.[Medline] [Order article via Infotrieve]
49. Bock RW, Gray-Weale AC, Mock PA, Robinson DA, Irwig L, Lusby RJ. The natural history of asymptomatic carotid artery disease. J Vasc Surg. 1993;17:160169.[Medline] [Order article via Infotrieve]
50. Tegos TJ, Sabetai MM, Nicolaides AN, Robless P, Kalodiki E, El-Atrozy TS, Ramaswami G, Dhanjil S. Correlates of embolic events on transcranial Doppler in patients with carotid atheroma. J Vasc Surg. In press.
51.
Evans GW, Howard G, Murros KE, Rose LA, Toole JF.
Cerebral infarction verified by cranial computed tomography and
prognosis for survival following transient ischemic attack.
Stroke. 1991;22:431436.
52.
The Dutch TIA Trial Study Group. Predictors of major
vascular events in patients with transient ischemic attack or
nondisabling stroke. Stroke. 1993;24:527531.
53. Blohme L, Sandstrom V, Hellstrom G, Swedenborg J, Takolander R. Complications in carotid endarterectomy are predicted by qualifying symptoms and preoperative CT findings. Eur J Vasc Endovasc Surg. 1999;17:213218.[Medline] [Order article via Infotrieve]
54.
Ferguson GG, Eliasziw M, Barr HWK, Clagett GP,
Barnes RW, Wallace MC, Taylor DW, Haynes RB, Finan JW, Hachinski VC,
Barnett HJM, for the North American Symptomatic Carotid
Endarterectomy Trial (NASCET) Collaborators. The
North American Symptomatic Carotid
Endarterectomy Trial: surgical results in 1415
patients. Stroke. 1999;30:17511758.
This article has been cited by other articles:
![]() |
M. Reiter, I. Effenberger, S. Sabeti, W. Mlekusch, O. Schlager, P. Dick, S. Puchner, J. Amighi, R. A. Bucek, E. Minar, et al. Increasing Carotid Plaque Echolucency is Predictive of Cardiovascular Events in High-Risk Patients Radiology, September 1, 2008; 248(3): 1050 - 1055. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Kwee, R. J. van Oostenbrugge, L. Hofstra, G. J. Teule, J.M.A. van Engelshoven, W. H. Mess, and M. E. Kooi Identifying vulnerable carotid plaques by noninvasive imaging Neurology, June 10, 2008; 70(24_Part_2): 2401 - 2409. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Martin, D. Gunnell, E. Whitley, A. Nicolaides, M. Griffin, N. Georgiou, G. Davey Smith, S. Ebrahim, and J. M. P. Holly Associations of Insulin-Like Growth Factor (IGF)-I, IGF-II, IGF Binding Protein (IGFBP)-2 and IGFBP-3 with Ultrasound Measures of Atherosclerosis and Plaque Stability in an Older Adult Population J. Clin. Endocrinol. Metab., April 1, 2008; 93(4): 1331 - 1338. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Reiter, R. A. Bucek, I. Effenberger, J. Boltuch, W. Lang, R. Ahmadi, E. Minar, and M. Schillinger Plaque Echolucency Is Not Associated With the Risk of Stroke in Carotid Stenting Stroke, September 1, 2006; 37(9): 2378 - 2380. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Watanabe, S. Sugiyama, K. Kugiyama, O. Honda, H. Fukushima, H. Koga, Y. Horibata, T. Hirai, T. Sakamoto, M. Yoshimura, et al. Stabilization of Carotid Atheroma Assessed by Quantitative Ultrasound Analysis in Nonhypercholesterolemic Patients With Coronary Artery Disease J. Am. Coll. Cardiol., December 6, 2005; 46(11): 2022 - 2030. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Goncalves, M.-L. M. Gronholdt, I. Soderberg, M. P.S. Ares, B. G. Nordestgaard, J. F. Bentzon, G. N. Fredrikson, and J. Nilsson Humoral Immune Response Against Defined Oxidized Low-Density Lipoprotein Antigens Reflects Structure and Disease Activity of Carotid Plaques Arterioscler. Thromb. Vasc. Biol., June 1, 2005; 25(6): 1250 - 1255. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ouhlous, H. Z. Flach, T. T. de Weert, J. M. Hendriks, M. R. H. M. van Sambeek, D. W. J. Dippel, P. M. T. Pattynama, and A. van der Lugt Carotid Plaque Composition and Cerebral Infarction: MR Imaging Study AJNR Am. J. Neuroradiol., May 1, 2005; 26(5): 1044 - 1049. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Goncalves, M. W. Lindholm, L. M. Pedro, N. Dias, J. Fernandes e Fernandes, G. N. Fredrikson, J. Nilsson, J. Moses, and M. P.S. Ares Elastin and Calcium Rather Than Collagen or Lipid Content Are Associated With Echogenicity of Human Carotid Plaques Stroke, December 1, 2004; 35(12): 2795 - 2800. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Biasi, A. Froio, E. B. Diethrich, G. Deleo, S. Galimberti, P. Mingazzini, A. N. Nicolaides, M. Griffin, D. Raithel, D. B. Reid, et al. Carotid Plaque Echolucency Increases the Risk of Stroke in Carotid Stenting: The Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) Study Circulation, August 10, 2004; 110(6): 756 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Honda, S. Sugiyama, K. Kugiyama, H. Fukushima, S. Nakamura, S. Koide, S. Kojima, N. Hirai, H. Kawano, H. Soejima, et al. Echolucent carotid plaques predict future coronary events in patients with coronary artery disease J. Am. Coll. Cardiol., April 7, 2004; 43(7): 1177 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Yamagami, K. Kitagawa, Y. Nagai, H. Hougaku, M. Sakaguchi, K. Kuwabara, K. Kondo, T. Masuyama, M. Matsumoto, and M. Hori Higher Levels of Interleukin-6 Are Associated With Lower Echogenicity of Carotid Artery Plaques Stroke, March 1, 2004; 35(3): 677 - 681. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Zureik, J.-M. Bureau, M. Temmar, C. Adamopoulos, D. Courbon, K. Bean, P.-J. Touboul, A. Benetos, and P. Ducimetiere Echogenic Carotid Plaques Are Associated With Aortic Arterial Stiffness in Subjects With Subclinical Carotid Atherosclerosis Hypertension, March 1, 2003; 41(3): 519 - 527. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. F. AbuRahma, J. T. Wulu Jr, and B. Crotty Carotid Plaque Ultrasonic Heterogeneity and Severity of Stenosis Stroke, July 1, 2002; 33(7): 1772 - 1775. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Yuan, L. M. Mitsumori, K. W. Beach, and K. R. Maravilla Carotid Atherosclerotic Plaque: Noninvasive MR Characterization and Identification of Vulnerable Lesions Radiology, November 1, 2001; 221(2): 285 - 299. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2000 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |