| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Stroke. 2003;34:2436.)
© 2003 American Heart Association, Inc.
Original Contributions |
From the Second Department of Internal Medicine, Kagawa Medical University (H.O., N.H., T.T., K.M., M.K.) and Osaka Neurosurgical Hospital (K.O.), Kagawa, Japan, and Department of Molecular and Experimental Medicine, Scripps Research Institute, La Jolla, Calif.
Reprint requests to Naohisa Hosomi, MD, PhD, Second Department of Internal Medicine, Kagawa Medical University, 1750-1 Ikenobe, Miki-Cho, Kagawa 761-0793, Japan. E-mail naohisa{at}kms.ac.jp
| Abstract |
|---|
|
|
|---|
Methods We evaluated 50 subjects with nonrheumatic continuous atrial fibrillation and a history of cardioembolic stroke. Each patient received an MRI and a transesophageal echocardiography (TEE) on the same day for thrombus detection in the LAA. Both double- and triple-inversion recovery sequences were used for the MRI evaluations.
Results In all subjects, the LAA was readily visualized with MRI. High-intensity masses in the LAA were clearly distinguishable from the LAA wall in the tripleinversion recovery sequences. Concordance between detection of high-intensity mass with MRI and thrombus with TEE was high: no mass (MRI), no thrombus (TEE), 31 patients; mass (MRI), thrombus (TEE), 16 patients; and mass (MRI), no thrombus (TEE), 3 patients (overall
=0.876, SE=0.068).
Conclusions MRI is a noninvasive and reproducible modality for thrombus detection in the LAA of patients with nonrheumatic continuous atrial fibrillation and previous cardioembolic stroke.
Key Words: atrial fibrillation magnetic resonance imaging stroke, cardioembolic thrombi
| Introduction |
|---|
|
|
|---|
| Materials and Methods |
|---|
|
|
|---|
MRI Study
MRI was performed on a 1.5-T whole-body MRI system (23 mT/m; slew rate, 120 mT · m-1 · ms-1; General Electric Medical Systems). A body coil was used for excitation. A 4-element (2 anterior elements, 2 posterior elements) phased-array coil was used for signal reception to obtain an improved signal-to-noise ratio. Patients were positioned supine, and ECG electrodes were attached to trigger data acquisition.
A long-axis image of the heart, which included the LAA, mitral valve, and apex cordis, was scanned on adjusting the angle and location with the fast gradient-echo (segmented k space) sequence. This long-axis image approximately represented the longitudinal 2-chamber view used for LAA evaluation with TEE. The first slice for the double- and triple-inversion recovery (IR) sequence was set on the plane in which the LAA was visualized with the fast gradient-echo sequence. Then, 3 slices were registered on each side of the first slice. The double-IR sequence reduced the blood signal and related artifacts and improved visualization of cardiac anatomy compared with nonprepared images. The delay time was manually adjusted for each examination scanning the LAA to visualize the systolic image. Finally, after the inversion time, a standard spin-echo slice-selective pulse was applied, and the image data were acquired. An additional third IR preparation pulse was applied for fat suppression and modification of image contrast (triple-IR sequence). The inversion time for the third IR pulse was set to 120 ms. The imaging parameters were as follows: repetition time, 2 RR intervals; echo time, 44 ms; field of view, 36 cm; slice thickness, 4 mm; interslice gap, 0; acquisition matrix, 256x128; number of samples averaged, 1; echo train length, 32; data sampling, 62.5 kHz; and delay time, 200 to 400 ms. The LAA was detected in 3 to 4 slices and a thrombus in 1 to 3 slices.
All subjects were instructed to suspend breathing at the end of expiration to minimize respiratory motion (no longer than 15 seconds in each scanning). We experienced 1 instance of an ECG gating problem, resulting in a limited cardiac motion artifact. Seven patients could not hold their breath; we found strong respiratory motion artifacts in these patients.
TEE Study
TEE was performed with a 5-MHz multiplane probe (LOGIC 500 with P509; General Electric). For each patient, all images were recorded as movie images on digital videotape in real time for display and evaluation. The images of the LA and the LAA were evaluated in both the horizontal (0°) plane and the plane obtained by rotation of the imaging sector from 0° to 180° during continuous visualization of the LAA. An LAA thrombus was defined as a well-circumscribed, uniformly consistent, echo-reflective mass of different texture from the LAA wall. Among the 50 patients, no thrombus was detected in the LA, excluding the LAA.
The severity of spontaneous echo contrast (SEC) was graded as poor (absence of detectable echogenicity), mild (swirling pattern and/or echogenicity located in the LAA), or severe (intense echodensity and swirling pattern in the LAA, generally associated with some density in the main cavity).3
Image Analysis
The MRI and TEE images were evaluated by different physicians (N.H. for MRI, H.O. for TEE), each of whom was blinded to the others findings. The MRI intensities of the LAA lumen, abnormal mass in the LAA, LAA wall, left ventricular lumen, and left ventricular wall were analyzed with an eFilm Workstation (eFilm Medical Inc). Relative intensities were calculated as a percentage of that of the left ventricular wall. LA dimension and LAA area were measured in the longitudinal 2-chamber view at the end-systolic cardiac cycle on the basis of the ECG with TEE.4,5 In TEE, the largest sizes in 10 consecutive cardiac cycles per patient were taken as LA dimension and LAA area. In MRI, LA dimension and LAA area were measured as with TEE, in the long-axis image that visualized the LAA with the double-IR sequence. The areas of a high-intensity mass and a thrombus were measured by tracing their surfaces manually6 from the images depicting their largest forms.
To estimate the reproducibility of thrombus detection and measurements of intensity, dimension, and area with MRI, the MRI images of 10 patients (5 with a high-intensity mass in the LAA, 5 with no mass) were evaluated by 10 trained cardiologists who were not involved in this study. There was no discrepant judgment of thrombus detection with MRI; intraobserver coefficients of variation of intensity, dimension, and area of MRI were 1.0%, 2.0%, and 1.2%, respectively, and interobserver coefficients of variation of intensity, dimension, and area of MRI were 2.2%, 3.6%, and 2.8%, respectively.
Summary statistics are presented as mean±SD. Comparison of LA dimension and LAA area measurements between TEE and MRI was assessed with concordance correlation coefficients (rc),7 along with jackknife estimates of their respective standard errors. Agreement between detection of high-intensity mass with MRI and thrombus with TEE was assessed with
statistics. Association between high-intensity MRI masses and SEC grade was assessed with the Cochran-Armitage
2 test for trend.
| Results |
|---|
|
|
|---|
The double- and triple-IR sequences were taken in all patients. In the subjects with no abnormal mass in LAA (13 women, 18 men), the LAA lumen was observed with MRI as low intensity in both the double-IR sequence (53.3±29.9%) and the triple-IR sequence (57.2±38.5%; Figure 1A and 1B). A high-intensity mass in the LAA was detected with MRI in 19 subjects (5 women, 14 men; Figure 1C and 1D). This high-intensity mass was well-circumscribed and uniformly consistent and had relative isointensity to the left ventricular wall in the double-IR sequence and relative high intensity in the triple-IR sequence with MRI (Figure 1C and 1D). The relative intensity to the left ventricular wall of this high-intensity mass in LAA was higher in the triple-IR sequence (186.2±44.4%) than in the double-IR sequence (142.9±44.7%; P<0.005; n=19). The LAA wall was detected as relative high intensity to the left ventricular wall in the double-IR sequence and relative isointensity in the triple-IR sequence (Figure 1C and 1D). The intensity of the LAA wall relative to the left ventricular wall was lower in the triple-IR sequence (91.1±31.2%) than in the double-IR sequence (170.7±54.9%; P<0.001; n=50). A high-intensity mass was thus clearly distinguishable from the LAA wall in the triple-IR sequence.
|
Agreement between detection of high-intensity mass with MRI and thrombus with TEE was high (the Table): overall
=0.876 (SE=0.068). On the other hand, sizes of high-intensity masses in MRI (71.1±16.3 mm2) were consistently greater than corresponding thrombus sizes in TEE (58.3±14.6 mm2); a 95% confidence interval for the difference is 9.2 to 16.4 mm2, with sizes being
23% larger with MRI than with TEE.
|
High-intensity masses were more likely to be found in patients with severe SEC grades (the Table; Cochran-Armitage
2 test for trend,
21=18.9; P<0.0001). Similarly, intensities of LAA lumen increased with increasing SEC grade (the Table). Of the 3 patients with a high-intensity mass on MRI but without a thrombus echo on TEE, SEC was categorized as severe in 2 and mild in the third.
| Discussion |
|---|
|
|
|---|
In subjects with severe SEC, the LAA lumen had relatively high intensity (the Table). When there was a thrombus in SEC, a high-intensity mass came up in SEC with much higher intensity in the triple-IR sequence image. The relative intensity of thrombus was significantly higher than the relative intensity of SEC in the triple-IR sequence. Hence, we could differentiate thrombus from SEC.
MRI is a noninvasive and reproducible modality for thrombus detection. We experienced unsuccessful TEE probe insertion in 11 patients in this study. With regard to accuracy, MRI and TEE provided equivalent LA dimension and LAA area measurements in our cohort. On the other hand, high-intensity masses in MRI were consistently
20% larger than thrombus sizes on TEE. In addition, MRI may be more sensitive than TEE; high-intensity masses were detected in 3 patients with no corresponding thrombus in TEE. We have also reported the deletion of LAA thrombus detected with MRI after warfarin treatment in the preliminary case report.8 However, MRI cannot altogether replace TEE; patients who have implanted metallic devices (eg, artificial pacemaker or prosthetic valve) or claustrophobia are not suitable for MRI evaluation. We have experienced patients who had implanted metallic devices (n=3; artificial pacemaker [3 of 3], prosthetic valve [0 of 3]) or claustrophobia (n=1) in this study. We could not evaluate a mobility of thrombus and blood flow velocity with MRI. Additionally, the utility of MRI in patients with small thrombi or small LAA is unknown. Two subjects who showed a high-intensity mass in the LAA with MRI but no thrombus echo with TEE had strong respiratory motion artifacts, which could confound MRI findings. Because MRI is an evolving technology, an increase in magnet strength would reduce acquisition time of scans, which in turn might ameliorate potential motion artifacts. With improving cine MRI, we may be able to detect the mobility of LAA thrombus in the near future. MRI has several advantages over the methods or imaging modalities currently available for an assessment of cardiovascular disease.
At our institution, the cost of cardiac MRI is 70% greater than TEE, precluding its routine use for thrombus detection. Rather, MRI is used primarily with patients unsuitable for TEE. We are currently evaluating the utility of MRI in patients with small thrombi or small LAA.
| Acknowledgments |
|---|
We would like to show our appreciation to Yasuaki Kamada and Yuko Takahashi in Osaka Neurosurgical Hospital for their technical support on the MRI setting.
Received November 18, 2002; revision received April 15, 2003; accepted April 24, 2003.
| References |
|---|
|
|
|---|
2. Special report from the National Institute of Neurological Disorders and Stroke: classification of cerebrovascular diseases, III. Stroke. 1990; 21: 637676.
3. Fatkin D, Kelly RP, Feneley MP. Relations between left atrial appendage blood flow velocity, spontaneous echocardiographic contrast and thromboembolic risk in vivo. J Am Coll Cardiol. 1994; 23: 961969.[Abstract]
4. Block M, Hourigan L, Bellows WH, Reeves J3rd, Romson JL, Tran M, Pastor D, Schiller NB, Leung JM. Comparison of left atrial dimensions by transesophageal and transthoracic echocardiography. J Am Soc Echocardiogr. 2002; 15: 143149.[CrossRef][Medline] [Order article via Infotrieve]
5. Pollick C, Taylor D. Assessment of left atrial appendage function by transesophageal echocardiography: implications for the development of thrombus. Circulation. 1991; 84: 223231.
6. Bashir M, Asher CR, Garcia MJ, Abdalla I, Jasper SE, Murray RD, Grimm RA, Thomas JD, Klein AL. Right atrial spontaneous echo contrast and thrombi in atrial fibrillation: a transesophageal echocardiography study. J Am Soc Echocardiogr. 2001; 14: 122127.[CrossRef][Medline] [Order article via Infotrieve]
7. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989; 45: 255268.[CrossRef][Medline] [Order article via Infotrieve]
8. Ohyama H, Mizushige K, Hosomi N. Magnetic resonance imaging of left atrial thrombus. Heart. 2002; 88: 233.
This article has been cited by other articles:
![]() |
E. Donal, J. A. Sallach, R. D. Murray, J. K. Drinko, S. E. Jasper, J. D. Thomas, and A. L. Klein Contrast-enhanced tissue Doppler imaging of the left atrial appendage is a new quantitative measure of spontaneous echocardiographic contrast in atrial fibrillation Eur J Echocardiogr, January 1, 2008; 9(1): 5 - 11. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. K. Mohrs, B. Nowak, S. E. Petersen, M. Welsner, C. Rubel, A. Magedanz, H.-U. Kauczor, and T. Voigtlaender Thrombus Detection in the Left Atrial Appendage Using Contrast-Enhanced MRI: A Pilot Study Am. J. Roentgenol., January 1, 2006; 186(1): 198 - 205. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Donal, H. Yamada, C. Leclercq, and D. Herpin The Left Atrial Appendage, a Small, Blind-Ended Structure: A Review of Its Echocardiographic Evaluation and Its Clinical Role Chest, September 1, 2005; 128(3): 1853 - 1862. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Spuentrup, B. Fausten, S. Kinzel, A. J. Wiethoff, R. M. Botnar, P. B. Graham, S. Haller, M. Katoh, E. C. Parsons Jr, W. J. Manning, et al. Molecular Magnetic Resonance Imaging of Atrial Clots in a Swine Model Circulation, July 19, 2005; 112(3): 396 - 399. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |