Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2007;38:e67
Published online before print June 21, 2007, doi: 10.1161/STROKEAHA.107.487660
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
38/8/e67    most recent
STROKEAHA.107.487660v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Froio, A.
Right arrow Articles by Biasi, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Froio, A.
Right arrow Articles by Biasi, G. M.
Related Collections
Right arrowRelated Article

(Stroke. 2007;38:e67.)
© 2007 American Heart Association, Inc.


Letters to the Editor

Carotid Plaque Echolucency Predicts the Risk of Stroke in Carotid Stenting According to the Type of Brain Protection Device and the Learning Curve

Alberto Froio, MD Giorgio M. Biasi, MD, FACS, FRCS

University of Milano-Bicocca, Department of Surgical Sciences, Vascular Surgery Unit, San Gerardo Hospital, Monza, Italy

To the Editor:

Dr Reiter analyzed the relationship between carotid plaque morphology and the risk of stroke after carotid artery stenting (CAS), showing that the grayscale median (GSM) is not associated with adverse outcome.1

In the ICAROS Study, we demonstrated that GSM is a predictor of stroke during CAS.2

Dr Cremonesi, with one of the biggest CAS experiences, has already demonstrated Dr Reiter’s findings. They treated patients with a GSM <25 with a proximal brain protection device not requiring the crossing of the soft lesion.3 Interestingly, they found visible debris during the procedure in 66.7% of patients, confirming the embolic potential of carotid plaques with a GSM <25. Using this brain protection device, the rate of stroke was not increased by GSM. The message is that a tailored technique in skilled interventionalists can overcome the risk of stroke caused by echolucent carotid plaques. For few centers with excellent results, carotid plaque morphology could not be a predictor of stroke, but for most centers not performing hundreds of cases per year (or starting a CAS program!), GSM is a strong predictor of stroke.

The same conclusion could be reached analyzing the outcome of CAS in octogenarians. The CREST Trial showed that the rate of stroke and death increases at older ages, being 12.1% in octogenarians.4 However, Dr Cremonesi showed that CAS is safe in elderly patients, with an overall death and stroke rate of 2.12%.5

Why are Cremonesi’s and Reiter’s conclusions not consistent with those in previous articles (CREST or ICAROS)? Those authors performing hundreds of procedures are unrepresentative of interventionalists with smaller number of cases. The learning curve in CAS is fundamental. The same author (Cremonesi participated in the ICAROS) may have both an increased and a nonincreased risk of stroke during CAS treating echolucent plaques, according to an improving learning curve over time because of a higher number of cases. How many interventionalists have treated 698 consecutive patients with such an excellent result (2.9%) to be allowed to discharge the GSM analysis before CAS? The issue is that the results published in the medical journals by few excellent centers are far better than those of the majority of the other hospitals. The EVA3S confirmed this finding, because the rate of stroke after CAS was far higher than showed by previous articles, probably because of a nonacceptable level of physician training.6

Should we perform the GSM analysis or not? The message should be the following:

In case of echolucent plaques, the embolic load to the brain will be higher. The rate of stroke will be increased.

The stroke rate could not be influenced by carotid plaque morphology if there is huge experience in carotid stenting (several hundreds of cases) or if proximal brain protection device is used that does not require the crossing of the lesion; however, the correct selection of a brain protection device may depend on GSM.

Carotid plaque morphology could influence the risk of late neurological dysfunction. The incidence of silent brain ischemia following CAS is high ({approx}20% to 30%), both in protected and unprotected procedures. The higher the incidence of silent ischemia, the higher the risk of dementia. The use of the GSM has the potential to select patients with the lower embolic load to the brain, reducing the risk of late neurological dysfunction.

The evaluation of carotid plaque echolucency should always be recommended for risk stratification in CAS patients.

Acknowledgments

Disclosures

None.

References

1. Reiter M, Bucek RA, Effenberger I, Boltuch J, Lang W, Ahmadi R, Minar E, Schillinger M. Plaque echolucency is not associated with the risk of stroke in carotid stenting. Stroke. 2006; 37: 2378–2380.[Abstract/Free Full Text]

2. Biasi GM, Froio A, Diethrich EB, Deleo G, Galimberti S, Mingazzini P, Nicolaides AN, Griffin M, Raithel D, Reid DB, Valsecchi MG. Carotid plaque echolucency increases the risk of stroke in carotid stenting: the imaging in carotid angioplasty and risk of stroke (icaros) study. Circulation. 2004; 110: 756–762.[Abstract/Free Full Text]

3. Cremonesi A, Manetti R, Liso A, Ricci E, Bianchi P, Castriota F. Endovascular treatment of soft carotid plaques: a single-center carotid stent experience. J Endovasc Ther. 2006; 13: 190–195.[CrossRef][Medline] [Order article via Infotrieve]

4. Hobson RW, 2nd, Howard VJ, Roubin GS, Brott TG, Ferguson RD, Popma JJ, Graham DL, Howard G. Carotid artery stenting is associated with increased complications in octogenarians: 30-day stroke and death rates in the crest lead-in phase. J Vasc Surg. 2004; 40: 1106–1111.[CrossRef][Medline] [Order article via Infotrieve]

5. Setacci C, de Donato G, Chisci E, Setacci F, Pieraccini M, Cappelli A, Palasciano G, Castriota F, Cremonesi A. Is carotid artery stenting in octogenarians really dangerous? J Endovasc Ther. 2006; 13: 302–309.[CrossRef][Medline] [Order article via Infotrieve]

6. Setacci C, Cremonesi A. Space and eva-3s trials: The need of standards for carotid stenting. Eur J Vasc Endovasc Surg. 2007; 33: 48–49.[CrossRef][Medline] [Order article via Infotrieve]


Related Article:

Response to the Letter by Froio and Biasi
Markus Reiter and Martin Schillinger
Stroke 2007 38: e68. [Extract] [Full Text] [PDF]




This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
38/8/e67    most recent
STROKEAHA.107.487660v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Froio, A.
Right arrow Articles by Biasi, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Froio, A.
Right arrow Articles by Biasi, G. M.
Related Collections
Right arrowRelated Article