Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2009;40:163-168
Published online before print October 23, 2008, doi: 10.1161/STROKEAHA.108.523621
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
40/1/163    most recent
STROKEAHA.108.523621v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rand, D.
Right arrow Articles by Hung, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rand, D.
Right arrow Articles by Hung, C.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Exercise for Children
*Exercise and Physical Fitness
*Stroke
Related Collections
Right arrow Exercise/exercise testing/rehabilitation

(Stroke. 2009;40:163.)
© 2009 American Heart Association, Inc.


Original Contributions

How Active Are People With Stroke?

Use of Accelerometers to Assess Physical Activity

Debbie Rand, PhD, OT; Janice J. Eng, PhD, PT/OT; Pei-Fang Tang, PhD, PT; Jiann-Shing Jeng, MD, PhD Chihya Hung, MSc, PT

From the Department of Physical Therapy (D.R., J.J.E., C.H.), University of British Columbia & Rehab Research Lab, GF Strong Rehab Centre, Vancouver, Canada; the School and Graduate Institute of Physical Therapy (P.-F.T.), College of Medicine, National Taiwan University and the Physical Therapy Center and the Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan, ROC; the Department of Neurology (J.-S.J.), National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan, ROC; and the International Collaboration on Repair Discoveries (D.R., J.J.E.), Vancouver, Canada.

Correspondence to Janice J. Eng, PhD, PT/OT, Department of Physical Therapy, University of British Columbia, T325 - 2211 Westbrook Mall, Vancouver, BC, V6T 2B5, Canada. E-mail Janice.Eng{at}vch.ca


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background and Purpose— Accelerometers are a unique tool used to objectively measure free-living physical activity, but their reliability for people with stroke has not been established. The primary aim was to assess the day-to-day reliability of these instruments for the paretic and nonparetic hips. The secondary aims were to measure the amount of physical activity with accelerometers that people with stroke undertake in the community and its relationship with walking capacity (6-minute walk test distance).

Methods— Forty people with stroke wore one Actical accelerometer on each hip for 3 consecutive days at home and during the 6-minute walk test in the laboratory. The accelerometer measured physical activity using total activity counts per day and energy expenditure (kcal/d).

Results— Excellent intraclass correlation coefficients (ICCs) for the activity counts (paretic hip ICC[1,3]=0.95, nonparetic hip ICC[1,3]=0.94) and for the energy expenditure (paretic hip ICC[1,3]=0.95, nonparetic hip ICC[1,3]=0.95) were found across the 3 consecutive days at home. Excellent ICCs were also found between the paretic versus the nonparetic hips for the activity counts (ICC[1,3]=0.98) and for the energy expenditure (ICC[1,3]=0.96). Free-living physical activity was very low and 58% of the participants did not meet recommended physical activity levels. Only moderate correlations (r=0.6 to 0.73, P<0.001) were found between the 6-minute walk test distance in the laboratory and 3-day physical activity recording at home.

Conclusions— The accelerometer was found to be a reliable objective instrument. The use of accelerometers quantified the low level of free-living physical activity of people with stroke.


Key Words: accelerometers • community-dwelling • physical activity • stroke


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Assessing walking and other physical activities of people with chronic conditions outside the laboratory is essential. There have been recent innovations to capture this measure in the general population.1 Accelerometers worn on the hip provide real-time estimates of the frequency, intensity, and duration of physical activity.1,2 Although pedometers are also a tool for monitoring physical activity, these tools simply count the number of steps taken per day.3,4 The accelerometers, on the other hand, provide measures of physical activity intensity through activity counts. Activity counts can then be converted to energy expenditure.2 Thus, accelerometers cannot only differentiate between walking slowly versus briskly, but also account for other common movements involved in daily activities of living such as rising from a chair.5 Although physical activity can be captured by self-report questionnaires, Hagstromer et al1 revealed that values of physical activity obtained by real-time accelerometers in 1114 healthy adults (ages 18 to 69 years) were much lower than that from self-report recall.

Although some psychometric properties of accelerometer measures to capture real-time free-living physical activity have been established for healthy adults, they have not been established for people living with stroke in the home and community. Reliability is the degree to which measurements are free from error and is a prerequisite to establishing validity or using an instrument as an outcome measure.6 Excellent test–retest reliability of the accelerometer has been found for 20 young adults for different treadmill speeds (intraclass correlation coefficient [ICC]=0.87 to 0.92)7 and for 40 older adults (mean age 76 years) for sitting and treadmill walking (ICC=0.97).8 Welk9 assessed the test–retest reliability of 4 different types of accelerometer monitors while college students completed 3 5-minute bouts of treadmill walking (3 mph). The ICCs ranged from 0.62 to 0.80 for all 4 types of monitors.9 Although the reliability of treadmill bouts has been established, no study has assessed the reliability of accelerometers for free-living physical activity (all the wake hours) between separate days for healthy populations.

Different models of accelerometers have been compared in healthy populations over several days and between the right and left hips. Paul et al10 assessed the correlation between 2 types of accelerometers (Actigraph and Actical) with 56 healthy subjects (aged 30 to 60 years) who wore the monitors for 15 days. They found that both activity monitors predict physical activity and a conversion equation can be used to compare the readings from the 2 models. Thus, although there is some variability between the various models, accelerometers are a reliable tool to monitor physical activity in healthy populations. Furthermore, it does not appear to matter which hip the accelerometer is worn on for healthy adults because excellent reliability (ICC=0.73 to 0.76) has been found between the right and left hips of 20 young adults for different treadmill speeds7 and for 10 young adults (ICC >0.97) over 24 hours.11

However, the psychometric properties of studies with healthy populations cannot be generalized to people with stroke because they walk slowly and their gait is typically asymmetrical with abnormal gait biomechanics.12 A limited number of studies have used accelerometers to assess physical activity in populations that may demonstrate gait impairments. Haeuber et al13 used a mechanical accelerometer (Caltrac) located on the nonparetic side to estimate the total activity counts and energy expenditure. They found the Caltrac accelerometer to have poor test–retest reliability (ICC=0.44) during 2 separate 24-hour periods of free-living activity in 17 people with chronic stroke aged 65±6 years. However, the Caltrac is a uniaxial accelerometer and may not capture the altered gait movements that are known to occur in nonsagittal planes. Motl et al14 assessed the physical activity of 193 subjects (mean age 46 years) with multiple sclerosis with an Actigraph accelerometer worn on the hip for 7 days and reported good ICC reliability over 3 days (0.80) and 7 days (0.93). They found no difference in physical activity between days in the week or weekends.

Accelerometers are a unique tool to objectively measure real-time free-living physical activity.15 The reliability of these monitors for people with stroke has not been well established and it is unknown whether there are differences between measures when worn on the paretic or nonparetic hips. We proposed to evaluate the use of accelerometers worn on both hips of people living with stroke for monitoring free-living physical activity. Our primary aim was to assess the reliability of accelerometers (1) across the 3 consecutive days for both hips; and (2) between accelerometers worn on the paretic versus the nonparetic hip. Our secondary aims were (1) to measure the amount of physical activity over 3 days; and (2) to determine the relationship of activity recorded during a laboratory-based measure of walking capacity (6-minute walking test [6MWT]) to that of free-living activity in the community. The 3-day period was chosen because a minimum of 3 days has been shown to achieve reliability of 0.80 for pedometer measures in healthy adults3 and for accelerometer measures in patients with multiple sclerosis.14


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Participants
Forty adult community-dwelling people with stroke volunteered to participate in the study. Participants were recruited through the local hospital stroke registry database. This study was approved by the local university ethics board, and all eligible subjects gave written informed consent before participating in the study. The diagnosis of the stroke was made by a neurologist based on both clinical characteristics and neuroimaging findings. All subjects were assessed by at least one brain imaging modality (CT or MRI). The inclusion criteria included: had a single unilateral stroke at least 6 months ago, living in the community, and had the ability to walk with or without a walking device. Exclusion criteria included: (1) unstable medical condition; (2) chest pain, heart attacks, angioplasty, or heart surgery in the previous 3 months; and (3) significant neurological or musculoskeletal problems from other than stroke. The Chedoke-McMaster Stroke Assessment16 was used to measure and determine the presence and severity of leg, foot, arm, and hand physical impairments. The Chedoke-McMaster Stroke Assessment has good concurrent validity with the Fugl-Meyer Assessment of Sensorimotor Recovery16 and moderate correlations with burden of care and activities of daily living (Barthel Index).17

Accelerometer Measures of Physical Activity
Accelerometers were used to measure participation in physical activity in the real world setting. The Actical (Mini-Mitter Co) accelerometer was used to obtain measurements. The Actical was selected because it is a triaxial, waterproof accelerometer and has been found to be superior to 2 other commonly used accelerometers (Actigraph and RT3) for intrainstrument and interinstrument reliability.18 Heil19 found the Actical to predict activity energy expenditure, which is the relative energy expenditure (kcal/kg per minute) to perform a task above the resting metabolism. His study included children and young adults undertaking 10 different activities such as floor sweeping and treadmill walking.

The Actical accelerometer is a small (28X27X10 mm), lightweight (17 g) sensor, which has a frequency range of 0.3 to 3 Hz, is sensitive to 0.05 to 2.0 G force, and samples at 32 Hz. It detects acceleration in all 3 planes, although it is more sensitive in the vertical direction. Data are rectified, integrated, and then stored as activity counts every 15 seconds (epoch); the count data in each epoch represents the intensity of the activity performed. Data were expressed as total activity counts per day and the total energy expenditure per day (kcal/d). The accelerometer detects low-frequency G forces common to human movement. Our own experience is that the accelerometer is sensitive to movements, including large movements (transfers) as well as small movements of the trunk (shifting weight while sitting). However, because the accelerometer is worn on the hip, if the person simply taps their foot while sitting, no activity counts are generated.

Procedure
The participants wore an elastic belt with 2 small Actical monitors positioned over the anterior–superior iliac spine for 3 consecutive days and were instructed to go about their normal lives. Within the laboratory, participants performed the 6MWT with the accelerometers in which participants walked as far as they could for 6 minutes with their usual assistive device (eg, cane).20 This distance is a measure of functional capacity because it requires a reasonable level of physical activity over a time period that may be associated with activities of daily living.21 The 6MWT was administered twice (once when the accelerometers were initially provided and 4 days later when the subjects returned the accelerometers). The results from the second test were analyzed because the first assessment is considered necessary for practice.20

Statistical Analysis
Shapiro-Wilk normality test was used to determine if the sample followed a normal distribution. Descriptive statistics were used to characterize the study population using means and SDs when relevant. The reliability of the Actical accelerometer activity counts and energy expenditure was assessed across the 3 days and between monitors worn on opposite hips. The ICC(1,k) with 95% CIs provided a measure of relative reliability to assess the relationship between 2 or more sets of repeated measures where k represents the number of measurements.22 A one-way random analysis of variance model was used because the subjects were the "raters" (they put on and wore the accelerometers independently after being taught). This model is considered to provide a more conservative estimate of reliability than the other 2-way models.23 ICC values >0.75 were considered "excellent reliability" and values between 0.4 and 0.75 were considered "fair to good reliability.24 ICCs can be used with both parametric and nonparametric data,25 with small samples, and with data from more than 2 testing times.26

A measure of absolute reliability, to describe the within-subject variability due to repeated measures, was obtained by calculating the SEM where SEM=SDXx{surd}1–ICC and SEM%=(SEM/mean)x100%. The SEM was then used to estimate the minimal detectable change (MDC), which is the minimal amount of change that is probably not due to chance variation in measurement where MDC95= SEMx1.96x{surd}2 and MCD%=(MDC95/mean)x100%. The estimate of SEM and MDC allows clinicians to determine if the change observed represents real improvement.27

Finally, we determined the relationship of activity recorded during a laboratory-based measure of functional capacity (6MWT) with that of free-living physical activity in the community. For this analysis, accelerometer readings of the paretic and nonparetic hips during the 6MWT were correlated (1) to the distance walked during the 6MWT; and (2) to the accelerometer readings during the 3 days at home. Spearman correlation coefficients were used because the physical activity variables were not normally distributed.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
The demographic information of the population is presented in Table 1. Fourteen participants wore the accelerometers during weekdays only, whereas the wearing time for 26 participants included a weekend. The accelerometer activity and the energy expenditure (for each hip) over the 3 days appear in Table 2. Paired t tests between the daily weekday (mean±SD 30 973±36 514 activity counts) and the weekend activity (29 354±33 949 activity counts) for those participants who wore the accelerometer over the weekend revealed no significant differences. The participants wore the accelerometers for an average of 15±1.8 hours a day with wearing time ranging from 10 to 18 hours a day. The participants spent 13±2 hours a day (out of their wake hours) without hip movements in which the accelerometer on the hip recorded zero activity counts per minute.


View this table:
[in this window]
[in a new window]

 
Table 1. Demographic and Stroke Characteristics of the Study Population (N=40)


View this table:
[in this window]
[in a new window]

 
Table 2. Accelerometer Activity Counts and Energy Expenditure (kcal/day) Recorded From the Paretic and Nonparetic Hips (mean±SD; N=40)

Excellent ICCs with narrow CIs for the activity counts and for the energy expenditure were found for the 3 consecutive days at home for both the paretic (ICC[1,3] >0.95) and nonparetic hips (ICC[1,3] >0.94; Table 3). Excellent ICCs between the paretic versus the nonparetic hips were also found for the activity counts (ICC[1,3]=0.94 to 0.99; 95% CI, 0.94 to 0.99) and energy expenditure (ICC[1,3]=0.95 to 0.96; 95% CI, 0.91 to 0.97) for 3 days. In addition, the analysis of variance found no difference between the paretic and nonparetic hip values. Smaller SEM% and MDC% values reflect lower measurement errors and greater responsiveness as compared with higher SEM% and MDC% values (Table 3).


View this table:
[in this window]
[in a new window]

 
Table 3. Relative (ICC) and Absolute Reliability (SEM, MDC) of the Accelerometers for Day-to-Day Free-Living Physical Activity Over 3 Days (N=40)

The distance walked during the 6MWT was 318.8±78.6 m and 15 of the subjects used a cane for walking. The accelerometers were also worn while the participants completed the 6MWT. The mean total activity count for the paretic hip during the 6MWT was 9000±6169 and 9574±6760 activity counts for the nonparetic hip.

Strong significant correlations were found between the distance walked in 6 minutes to the activity counts registered on the paretic hip (r=0.89, P<0.001) and nonparetic hip (r=0.98, P<0.001) during the 6MWT. Moderate significant correlations were found between the distance walked in 6 minutes to the activity counts registered on the paretic hip (r=0.67, P<0.001) and nonparetic hip (r=0.73, P<0.001) during 3 days at home.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
The accelerometer provided an accurate and reliable measure of day-to-day free-living physical activity level of people with stroke living in the community. There was excellent day-to-day reliability between the 3 consecutive days (ICC >0.94; 95% CI, 0.91 to 0.97) and acceptable measurement error (SEM%=19.3% to 30.8%). These findings are consistent with the 3-day reliability (ICC=0.80) found for people with multiple sclerosis14 and substantially higher when using an uniaxial accelerometer between 2 days (ICC=0.44) for people with stroke.13 McClain et al11 argued that it was not realistic to assess reliability of activity in the free-living environment because most people vary their routine from day to day. The low between-day variability found in our study indicates that the participants may have a routine with similar core activities each day. Because all of the participants were retired, the day-to-day activity may have been more consistent and we found no differences between weekdays and weekend activity. In addition, besides wearing the belt in the prescribed manner for all the wake hours, no other parameters of the accelerometer needed to be changed or adjusted by the subject. The data are downloaded and analyzed by the Actical software, which is also not dependent on any subjective analyses.

As expected, our absolute reliability estimates are higher than the 10% SEM28,29 for test–retest reliability of clinical gait and balance measures of persons with chronic stroke because those are measures performed with specific tasks under precise instructions. This contrasts with our accelerometer measures in which we instructed participants "to go about their normal lives" over 3 days. Nevertheless, our SEM estimates for the activity counts and energy expenditure are similar to those reported in persons with hemiparesis for other typical instrumented measures such as grip strength (20%)30 and for an upper limb trajectory-tracking task (24% to 36%).31

It is well recognized that people with stroke walk slowly and that their gait is typically asymmetrical with abnormal gait biomechanics.12 Regardless of this fact, excellent ICCs (>0.96) were found between the reading of the accelerometer located above the paretic hip versus the accelerometer located above the nonparetic hip and no significant differences were found between paretic and nonparetic hip values. The high ICCs in part reflect the mechanical link between the 2 accelerometers, which are placed on either side of the rigid pelvis segment. Some components of acceleration (eg, forward acceleration) will be similar between the 2 sides when the whole body mass is moving forward while walking. Therefore, in future studies, it is sufficient to use one accelerometer located on either hip to record the free-living activity of this population.

Our sample represents people with a mild motor impairment after a stroke; a mean 318.8 m 6MWT translates to a gait speed of 0.89 m/s, which is sufficient to meet the highest level of walking category in people with stroke (eg, independent in all home and community activities, complete independence in shopping centers).32 In addition, participants had a median of 7 on the physical impairment scores, which is the highest stage of motor recovery. However, our sample of people with mild motor impairment still had substantial limitations compared with healthy individuals; 318.8 m during the 6MWT is 36% less than normative 6MWT values from 4809 community-dwelling individuals aged 60 years or older (mean of 499 m; range, 480 to 519 m).33 A distance <400 m within 6 minutes has been associated with higher risk of mortality.34

The energy expenditure from the accelerometers revealed concerning findings; most of these community-dwelling participants with mild motor impairment after stroke do not meet the recommended level of physical activity. The recommended intensity of physical activity for adults is above 1000 kcal/week (142 kcal/d), possibly reaching 1500 to 2000 kcal/week (215 to 285 kcal/d), including at least 30 minutes of exercise a day.35 These intensities are important for reducing morbidity and preventing the development of secondary chronic diseases. Twenty-two participants (58%) did not reach 142 kcal/d, 9 participants (27%) used between 142 and 285 kcal/d, whereas only 4 participants (18%) used more than 286 kcal/d. Reduced activity after stroke can lead to disuse atrophy and cardiovascular deconditioning and subsequent loss in the functional gains achieved during rehabilitation. In particular, people with stroke are at high risk of cardiovascular disease and recurrent stroke, and regular physical activity is one lifestyle modification recommended to reduce the risk of these conditions.36

In addition to energy expenditure, the activity counts can also be used to demonstrate the lack of activity of our sample. The algorithms used to calculate energy expenditure are based on healthy individuals. People living with stroke may have higher energy costs while ambulating.37 Thus, it is also useful to examine the raw activity counts and conversion formulas that have been validated between Actical and Actigraph data.10 During the 3-day collection, our participants with stroke had a mean 62.8±90.4 activity counts/minute recorded over the paretic hip. Our own database of 40 healthy older adults (mean age 71.3±3.8 years) had a mean activity count per minute of 150±75 (unpublished data from 7-day accelerometer hip recording), which is over double that of the participants with stroke. McClain et al11 classified those below a threshold of 435 Actical-converted activity counts/minute as sedentary in healthy young adults. Ham et al38 reported a mean of 721 Actical-converted activity counts/minute for 12 healthy subjects aged 22 to 56 years over 7 consecutive days while Hagstromer et al1 reported 323±120 Actical-converted activity counts/minute for 1114 subjects (mean age 44.5±14 years). In fact, our finding of 62.8 activity counts/minute translates to the physical activity recorded during sitting activities (12 to 77 activity counts/minute).19 Despite the fact that the population in the current study is older than that found in the literature, the disparity between the activity counts of our participants and the other populations is vast, emphasizing the fact that the people with stroke in the current study had low activity levels.

Despite sufficient ability to walk within the laboratory, many individuals demonstrated low levels of physical activity at home. Only moderate correlations were found between the distance walked during the 6MWT (measure of walking capacity under ideal conditions) and the activity counts during the 3 days at home (measure of participation in physical activities). This relationship is presented graphically in the Figure in which despite the fact that some people do have the ability to walk a considerate distance in the 6MWT (eg, >400 m), they do not use this potential to engage in physical activity. Thus, a number of subjects have a high 6MWT and low 3-day activity count. This observation is similar to the phenomenon of upper extremity "learned nonuse"39 described in an article appropriately titled "Stroke Recovery; He Can But Does He?" These subjects with stroke demonstrated the ability to use the arm in the clinic setting but did not use their arm at home.40 Clinicians should be aware that even people with stroke who have mild motor impairment present a low level of physical activity and should be encouraged to counsel these individuals to engage in leisure, sport, and fitness programs that enhance physical activity. There is preliminary evidence that physical activity counseling can increase physical activity behavior and participation in community-dwelling people with stroke.41,42


Figure 1523621
View larger version (10K):
[in this window]
[in a new window]

 
Figure. A scatterplot of the 3-day total physical activity count versus 6MWT distance.

Several limitations of this study should be acknowledged. The results can only be generalized to stroke participants with mild motor impairment who are community-living. Energy expenditure conversions were based on healthy norms, which may underestimate the energy cost of people with stroke; however, the low level of physical activity of our participants was also demonstrated using the raw activity counts. The accelerometer records activity due to multiple short bouts or less frequent but larger bouts. Unfortunately, to date, there are no established thresholds that could be used to differentiate between these types of activities, which may have different health benefits. However, future research will hopefully establish these guidelines.

Conclusions
This study assessed the day-to-day reliability of the Actical accelerometer and found it to be a reliable objective measure to determine the level of free-living activity in people with stroke. It was revealed that this community-dwelling sample of people living with stroke was very inactive. Accelerometers could be used as an outcome measure to determine whether rehabilitation promotes community reintegration in terms of physical activity. Further research could investigate uses of accelerometers to monitor and increase free-living physical activity in community-dwelling people living with stroke.


*    Acknowledgments
 
Sources of Funding

We would like to acknowledge the support of Grant No NHRI-EX96-9210EC (to P.-F.T.) from the National Health Research Institutes, Taiwan, ROC, postdoctoral funding (to D.R.; from the Heart and Stroke Foundation of Canada, Canadian Stroke Network, Canadian Institutes of Health Research [CIHR]/Rx&D Collaborative Research Program with AstraZeneca Canada Inc), career scientist awards (to J.J.E.) from CIHR and the Michael Smith Foundation for Health Research, and visiting professor awards (to J.J.E.) from ICORD and National Science Council (#NSC 96-2811-B-002-001, Taiwan).

Disclosures

None.

Received April 18, 2008; revision received May 20, 2008; accepted June 3, 2008.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Hagstromer M, Oja P, Sjostrom M. Physical activity and inactivity in an adult population assessed by accelerometry. Med Sci Sports Exerc. 2007; 39: 1502–1508.[CrossRef][Medline] [Order article via Infotrieve]

2. Esliger DW, Probert A, Gorber SC, Bryan S, Laviolette M, Tremblay MS. Validity of the Actical accelerometer step-count function. Med Sci Sports Exerc. 2007; 39: 1200–1204.[CrossRef][Medline] [Order article via Infotrieve]

3. Tudor-Locke C, Bassett DR Jr. How many steps/day are enough? Preliminary pedometer indices for public health. Sports Med. 2004; 34: 1–8.[CrossRef][Medline] [Order article via Infotrieve]

4. Tudor-Locke C, Burkett L, Reis JP, Ainsworth BE, Macera CA, Wilson DK. How many days of pedometer monitoring predict weekly physical activity in adults? Prev Med. 2005; 40: 293–298.[CrossRef][Medline] [Order article via Infotrieve]

5. White DK, Wagenaar RC, Del Olmo ME, Ellis TD. Test–retest reliability of 24 hours of activity monitoring in individuals with Parkinson’s disease in home and community. Neurorehabil Neural Repair. 2007; 21: 327–340.[Abstract/Free Full Text]

6. Streiner DL, Norman GR. ‘Precision’ and ‘accuracy’: two terms that are neither. J Clin Epidemiol. 2006; 59: 327–330.[CrossRef][Medline] [Order article via Infotrieve]

7. Nichols J, Morgan CG, Sarkin JA, Sallis JF, Calfas KJ. Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. Med Sci Sports Exerc. 1999; 31: 908–912.[Medline] [Order article via Infotrieve]

8. Kochersberger G, McConnell E, Kuchibhatla MN, Pieper C. The reliability, validity, and stability of a measure of physical activity in the elderly. Arch Phys Med Rehabil. 1996; 77: 793–795.[CrossRef][Medline] [Order article via Infotrieve]

9. Welk G. Reliability of accelerometry-based activity monitors: a generalizability study. Med Sci Sports Exerc. 2004; 36: 1637.[Medline] [Order article via Infotrieve]

10. Paul D, Kramer M, Moshfegh AJ, Baer DJ, Rumpler WV. Comparison of two different physical activity monitors. BMC Med Res Methodol. 2007; 7: 26.[CrossRef][Medline] [Order article via Infotrieve]

11. McClain JJ, Sisson SB, Tudor-Locke C. Actigraph accelerometer inter-instrument reliability during free-living in adults. Med Sci Sports Exerc. 2007; 39: 1509–1514.[CrossRef][Medline] [Order article via Infotrieve]

12. Kim CM, Eng JJ. Magnitude and pattern of 3D kinematic and kinetic gait profiles in persons with stroke: relationship to walking speed. Gait Posture. 2004; 20: 140–146.[CrossRef][Medline] [Order article via Infotrieve]

13. Haeuber E, Shaughnessy M, Forrester LW, Coleman KL, Macko RF. Accelerometer monitoring of home- and community-based ambulatory activity after stroke. Arch Phys Med Rehabil. 2004; 85: 1997–2001.[CrossRef][Medline] [Order article via Infotrieve]

14. Motl RW, Zhu W, Park Y, McAuley E, Scott JA, Snook EM. Reliability of scores from physical activity monitors in adults with multiple sclerosis. Adapt Phys Activ Q. 2007; 24: 245–253.[Medline] [Order article via Infotrieve]

15. Tudor-Locke CE, Myers AM. Challenges and opportunities for measuring physical activity in sedentary adults. Sports Med. 2001; 31: 91–100.[CrossRef][Medline] [Order article via Infotrieve]

16. Gowland C, Stratford P, Ward M, Moreland J, Torresin W, Van Hullenaar S, Sanford J, Barreca S, Vanspall B, Plews N. Measuring physical impairment and disability with the Chedoke-McMaster Stroke Assessment. Stroke. 1993; 24: 58–63.[Abstract/Free Full Text]

17. Valach L, Signer S, Hartmeier A, Hofer K, Cox Steck G. Chedoke-McMaster stroke assessment and modified Barthel Index self-assessment in patients with vascular brain damage. Int J Rehabil Res. 2003; 26: 93–99.[CrossRef][Medline] [Order article via Infotrieve]

18. Esliger DW, Tremblay MS. Technical reliability assessment of three accelerometer models in a mechanical setup. Med Sci Sports Exerc. 2006; 38: 2173–2181.[CrossRef][Medline] [Order article via Infotrieve]

19. Heil DP. Predicting activity energy expenditure using the Actical activity monitor. Res Q Exerc Sport. 2006; 77: 64–80.[Medline] [Order article via Infotrieve]

20. ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002; 166: 111–117.[Free Full Text]

21. Eng JJ, Chu KS, Dawson AS, Kim CM, Hepburn KE. Functional walk tests in individuals with stroke: relation to perceived exertion and myocardial exertion. Stroke. 2002; 33: 756–761.[Abstract/Free Full Text]

22. Rankin G, Stokes M. Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil. 1998; 12: 187–199.[Abstract/Free Full Text]

23. Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice II Edition. Upper Saddle River, NJ: Prentice Hall. 2000: 560–586.

24. Fleiss JL. The Design and Analysis of Clinical Experiment. New York: John Wiley & Sons; 1986.

25. Fleiss JL, Cohen J. The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability. Educ Psychol Meas. 1973; 33: 613–619.[CrossRef]

26. Lexell JE, Downham DY. How to assess the reliability of measurements in rehabilitation. Am J Phys Med Rehabil. 2005; 84: 719–723.[CrossRef][Medline] [Order article via Infotrieve]

27. Haley SM, Fragala-Pinkham MA. Interpreting change scores of tests and measures used in physical therapy. Phys Ther. 2006; 86: 735–743.[Abstract/Free Full Text]

28. Flansbjer UB, Holmbäck AM, Downham D, Patten C, Lexell J. Reliability of gait performance tests in men and women with hemiparesis after stroke. J Rehabil Med. 2005; 37: 75–82.[CrossRef][Medline] [Order article via Infotrieve]

29. Liaw LJ, Hsieh CL, Lo SK, Chen HM, Lee S, Lin JH. The relative and absolute reliability of two balance performance measures in chronic stroke patients. Disabil Rehabil. 2008; 30: 656–661.[CrossRef][Medline] [Order article via Infotrieve]

30. Boissy P, Bourbonnais D, Carlotti MM, Gravel D, Arsenault BA. Maximal grip force in chronic stroke subjects and its relationship to global upper extremity function. Clin Rehabil. 1999; 13: 354–362.[Abstract/Free Full Text]

31. Patten C, Kothari D, Whitney J, Lexell J, Lum PS. Reliability and responsiveness of elbow trajectory tracking. J Rehabil Res Dev. 2003; 40: 487–500.[Medline] [Order article via Infotrieve]

32. Perry J, Garrett M, Gronley JK, Mulroy SJ. Classification of walking handicap in the stroke population. Stroke. 1995; 26: 982–989.[Abstract/Free Full Text]

33. Bohannon R. Six-minute walk test: a meta-analysis of data from apparently healthy elders. Top Ger Rehabil. 2007; 23: 155–160.

34. Newman AB, Simonsick EM, Naydeck BL, Boudreau RM, Kritchevsky SB, Nevitt MC, Pahor M, Satterfield S, Brach JS, Studenski SA, Harris TB. Association of long-distance corridor walk performance with mortality, cardiovascular disease, mobility limitation, and disability. JAMA. 2006 3; 295: 2018–2026.[Abstract/Free Full Text]

35. Mazzeo RS, Tanaka H. Exercise prescription for the elderly: current recommendations. Sports Med. 2001; 31: 809–818.[CrossRef][Medline] [Order article via Infotrieve]

36. Wolf PA, Clagett GP, Easton JD, Goldstein LB, Gorelick PB, Kelly-Hayes M, Sacco RL, Whisnant JP. Preventing ischemic stroke in patients with prior stroke and transient ischemic attack: a statement for healthcare professionals from the Stroke Council of the American Heart Association. Stroke. 1999; 30: 1991–1994.[Free Full Text]

37. Zamparo P, Francescato MP, De Luca G, Lovati L, di Prampera PE. The energy cost of level walking in patients with hemiplegia. Scand J Med Sci Sports. 1995; 5: 348–352.[Medline] [Order article via Infotrieve]

38. Ham SA, Reis JP, Strath SJ, Dubose KD, Ainsworth BE. Discrepancies between methods of identifying objectively determined physical activity. Med Sci Sports Exerc. 2007; 39: 52–58.

39. Taub E, Miller NE, Novack TA, Cook EW III, Fleming WC, Nepomuceno CS, Connell JS, Crago JE. Technique to improve chronic motor deficit after stroke. Arch Phys Med Rehabil. 1993; 74: 347–354.[Medline] [Order article via Infotrieve]

40. Andrews K, Stewart J. Stroke recovery: he can but does he? Rheumatol Rehabil. 1979; 18: 43–48.[Medline] [Order article via Infotrieve]

41. van der Ploeg HP, Streppel KRM, van der Beek AJ, van der Woude LHV, Vollenbroek-Hutten MMR, van Harten WH, van Mechelen W. Counseling increases physical activity behavior nine weeks after rehabilitation. Br J Sports Med. 2006; 40: 223–229.[Abstract/Free Full Text]

42. Greenlund KJ, Giles WH, Keenan NL, Croft JB, Mensah GA. Physician advice, patient actions, and health-related quality of life in secondary prevention of stroke through diet and exercise. Stroke. 2002; 33: 565–570.[Abstract/Free Full Text]





This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
40/1/163    most recent
STROKEAHA.108.523621v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rand, D.
Right arrow Articles by Hung, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rand, D.
Right arrow Articles by Hung, C.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Exercise for Children
*Exercise and Physical Fitness
*Stroke
Related Collections
Right arrow Exercise/exercise testing/rehabilitation