Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2009;40:86-93
Published online before print October 16, 2008, doi: 10.1161/STROKEAHA.108.521393
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
40/1/86    most recent
STROKEAHA.108.521393v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Izquierdo-Garcia, D.
Right arrow Articles by Warburton, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Izquierdo-Garcia, D.
Right arrow Articles by Warburton, E. A.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Medline Plus Health Information
*MRI Scans
*Nuclear Scans
Hazardous Substances DB
*POTASSIUM
Related Collections
Right arrow Imaging
Right arrow Nuclear cardiology and PET
Right arrow Carotid Stenosis
Right arrow Computerized tomography and Magnetic Resonance Imaging
Right arrow PET and SPECT

(Stroke. 2009;40:86.)
© 2009 American Heart Association, Inc.


Original Contributions

Comparison of Methods for Magnetic Resonance-Guided [18-F]Fluorodeoxyglucose Positron Emission Tomography in Human Carotid Arteries

Reproducibility, Partial Volume Correction, and Correlation Between Methods

David Izquierdo-Garcia, PhD; John R. Davies, PhD, MRCP; Martin J. Graves, MSc; James H.F. Rudd, PhD, MRCP; Jonathan H. Gillard, MD, FRCR; Peter L. Weissberg, MD, FRCP; Tim D. Fryer, PhD Elizabeth A. Warburton, DM, MRCP

From Wolfson Brain Imaging Centre (D.I.-G., T.D.F.), Division of Cardiovascular Medicine (J.R.D., J.H.F.R., P.L.W.), Department of Radiology (M.J.G., J.H.G.), Clinical Neurosciences (E.A.W.), University of Cambridge, Addenbrooke’s Hospital, Cambridge, UK.

Correspondence to David Izquierdo-Garcia, PhD, Wolfson Brain Imaging Centre, University of Cambridge, Box 65, Addenbrooke’s Hospital, Cambridge, CB2 0QQ, UK. E-mail di219{at}wbic.cam.ac.uk


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMaterials and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background and Purpose— Inflammation is a major risk factor for atherosclerotic plaque rupture and clinical events. Previous studies have shown that plaque [18F]fluorodeoxyglucose (FDG) uptake correlates with macrophage content. In this study we examined the reproducibility of 3 methods of quantifying plaque FDG uptake in the carotid arteries using positron emission tomography (PET). The correlation between 2 simplified uptake parameters (standardized uptake value [SUV], vessel wall-to-blood ratio [VBR]) and a gold standard technique (influx rate [Ki]) was also determined. We used MRI to correct carotid plaque FDG uptake for partial volume error.

Methods— Seven patients with a recent carotid territory transient ischemic attack underwent imaging twice within 8 days using MR and FDG-PET. MR coregistered to PET was used to delineate regions of interest, and to facilitate partial volume correction (PVC).

Results— SUV was the most reproducible parameter irrespective of whether it was normalized by body surface area (BSA), lean body mass, or weight (intraclass correlation coefficient=0.85, 0.88, and 0.90, respectively). VBR correlated better to Ki than SUV (r=0.58 VBR, r=0.46 SUVBSA). PVC improved these correlations to r=0.81 VBR and r=0.76 SUVBSA, and only slightly degraded the reproducibility of SUV (intraclass correlation coefficient=0.83–0.85).

Conclusions— MR-guided FDG-PET is a highly reproducible technique in the carotid artery and the excellent anatomic detail provided by MR facilitates PVC. Of the methods examined, SUVBSAPVC appears to represent the best compromise between reproducible and accurate determination of FDG metabolism in carotid artery vessel wall.


Key Words: atherosclerosis • magnetic resonance imaging • positron emission tomography • partial volume correction • reproducibility


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMaterials and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Despite improvements in both primary and secondary prevention of atherosclerosis, the clinical syndromes it causes still account for one-third of all deaths. Rupture of an atherosclerotic plaque underlies most acute stroke either by thrombotic occlusion at the site of rupture or by distal embolization.1 The likelihood of plaque rupture is related to the inflammatory activity of the plaque rather than the degree of luminal obstruction it causes.2,3 Conventional imaging (x-ray angiography) fails as a predictive tool because it provides no information on plaque inflammation.4 Molecular imaging approaches to more accurately predict plaques at risk of rupture are therefore being investigated.5 One promising technique is to image the radiolabeled glucose analogue 18F-fluorodeoxyglucose (FDG) using positron emission tomography (PET), which we have already shown to be capable of identifying inflamed plaques in stroke patients with carotid and vertebral disease.6,7 However, if FDG-PET is to be used to assess stroke patients with extracranial atherosclerotic disease, then further methodological validation needs to be performed.

First, it remains uncertain as to how best to quantify FDG uptake within arterial wall and plaque despite several studies confirming that FDG-PET can differentiate atherosclerotic lesions according to their degree of inflammation.6,8–10 Vessel wall-to-blood ratio (VBR),9 whole vessel-to-blood ratio,11 differential uptake ratio,12 blood pool ratio,13 and standardized uptake value (SUV)14,15 have all been used. Although several studies have measured circulating FDG levels to normalize the plaque FDG uptake measurements,6,9,11 none of the published data has used Patlak analysis, a technique that calculates the rate at which FDG is transported into the cells and metabolized (Ki) by graphical analysis of blood sampling and PET data.16 This study is the first to our knowledge to examine the feasibility of determining Ki for plaque imaging and to compare it to other measures of plaque FDG uptake.

Second, the magnitude of the partial volume error (PVE) on measures of plaque FDG uptake and how these parameters are affected by partial volume correction (PVC) is currently unknown. PVE is the error that occurs as a result of limited spatial resolution;17 when quantifying regional tracer uptake with PET, the results are compromised by activity "spilling in" from adjacent regions and "spilling out" from the region of interest (ROI). In general, the smaller the ROI, the greater the PVE, although the relationship between size of ROI and degree of PVE is not straightforward because it also depends on the relative tracer uptake in the ROI to that in the surrounding tissues. PVE will lead to the overestimation of uptake in a region surrounded by higher uptake values and underestimation of uptake in a region surrounded by lower uptake values. In practice, it has been shown that PVE is minimal when the dimensions of a homogeneous uptake region are >2- to 3-times the spatial resolution of the scanner.18 The spatial resolution of most human PET scanners is {approx}6 mm, and thus quantification of tracer uptake in atherosclerotic plaques (typical size <5 mm)19 is likely to be significantly affected by PVE. The effect of PVE and correction for it has been studied extensively in brain PET.20–23 Following the general approach used most commonly in brain PET, we have used high-resolution magnetic resonance (HRMR) images coregistered to FDG-PET and the Rousset partial volume correction method21 to produce the first partial volume corrected results for atherosclerotic plaque imaging.

Very recently, the excellent test–retest reproducibility of FDG uptake in the carotid and aorta has been confirmed.11 However, results were only given for 1 FDG uptake parameter (whole vessel-to-blood ratio) and PVC was not applied. In this study the reproducibility of 3 measures of FDG uptake (VBR, SUV, Ki) have been compared, both with and without PVC.


*    Materials and Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Materials and Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patient Recruitment
Seven patients (6 males and 1 female, aged 62 to 78 years; mean age±SD, 71.4±6.3) with recent carotid-territory TIA and evidence of ipsilateral carotid stenosis on Doppler ultrasound examination were recruited. All patients were assessed by experienced stroke physicians before entry into the study, and commenced on aspirin and statin medication. Antihypertensive medication was used at the physician’s discretion. Patients with standard contraindications to MR or PET imaging were excluded. The study was approved by the local ethics committee and the UK Administration of Radioactive Substances Advisory Committee. All patients gave written informed consent.

All patients underwent 2 FDG-PET scans within 8 days (mean±SD, 4±2 days) to enable reproducibility to be assessed. HRMR was performed for coregistration, resulting in a fused image with both anatomic information and the distribution of FDG. Coregistered images were then used to determine plaque FDG uptake as described.

The PET and MR imaging protocols, together with the PET-MR coregistration method, have been described previously.7 Brief details are given.

PET Imaging
Data were acquired in 3-dimensional mode on a GE Advance PET scanner (General Electric Medical Systems) for 120 minutes (10x5 sec, 7x10 sec, 4x15 sec, 6x20 sec, 10x30 sec, 5x1 min, 5x2 min, 19x5 min) after an injection of 190 MBq FDG (191±16.3 MBq). An image was reconstructed for each timeframe using the PROMIS 3D filtered back-projection algorithm24 with corrections applied for attenuation, isotope decay, dead time, scatter, and random coincidences. A Hanning filter was applied transaxially to give a spatial resolution of {approx}6.8 mm in all 3 directions at the center of the field of view. Blood samples were drawn at various time points (20, 40, 60, 80, 100, 120 sec, followed by 3, 4, 5, 7, 10, 15, 25, 35, 45, 55, 65, 75, 90, 105, and 120 min after injection) to allow measurement of plasma FDG concentration.

MR Imaging
HRMR images of voxel size 0.4x0.4x3 mm3 were acquired over a field of view of {approx}10x10x6 cm around the carotid bifurcation using a T1-weighted sequence with fat saturation (TR=1xR–R interval; TE=7.7 ms [Ef]; ETL=12, where TR indicates repetition time; R–R, time interval between successive R waves; TE, echo time; Ef, effective echo time; ETL, echo train length). To facilitate coregistration with PET, a large field of view T1-weighted MR (1x1x1 mm3 voxel size) was also acquired, covering approximately the same volume as the field of view of the PET scanner.

PET and MR Coregistration
For this study the large field of view MR and the HRMR were automatically coregistered using the rigid normalized mutual information algorithm implemented in the VTK CISG Registration Toolkit (Computational Imaging Science Group, King’s College). For each PET scan, a mean PET image was coregistered (rigid transformation) to the large field of view MR using the software package MPITool (Max-Planck-Institut Für Neurologische Forschung) using anatomic landmarks present on both scans, such as spinal cord, submandibular glands, and soft tissue surrounding the skull and mandible. Fine manual adjustment was performed if needed to improve the coregistration of the PET image to the HRMR image. All PET images were then sliced again to the HRMR using the coregistration translations and rotations. Based on the position of the artery lumens in the HRMR and the coregistered PET images, we found that the coregistration accuracy in the region around the carotid artery is {approx}1.2 mm.

ROI Delineation
For each patient, 3-dimensional ROIs were manually drawn on contiguous transaxial planes of the HRMR using commercially available software (Analyze; AnalyzeDirect). For each carotid artery, separate ROIs were drawn for the vessel wall and lumen. In addition, ROIs were drawn around all anatomic structures within a 20-mm radius (3x full width at half maximum of the scanner resolution) of each carotid artery to give a total number of 15 ROIs to allow for PVC (Figure 1). Each ROI set was then transferred onto the corresponding coregistered PET images to allow for calculation of vessel wall FDG uptake.


Figure 1521393
View larger version (56K):
[in this window]
[in a new window]

 
Figure 1. An example of a set of regions of interest delineated on an MR scan and transferred to the coregistered PET scan to enable partial volume correction of vascular wall FDG uptake. In this example the regions have be placed on the right carotid artery (arrow) and its surrounding structures.

FDG Uptake Parameters
For each PET study, the following measures of vessel wall FDG uptake were calculated: SUV, VBR, and the influx rate (Ki). PVC was performed for each carotid vessel, giving the following measures of FDG uptake: SUVPVC, VBRPVC, and KiPVC.

SUV
SUV, a method of quantification that normalizes FDG uptake to the activity injected and a measure of patient size, was calculated from an averaged image of the last 30 minutes (6 frames) of the FDG scan using the following equation: equation


Formula 1

where X is either body weight (W, gram), lean body mass (LBM, gram)25 or BSA (cm2)26. The formulas used for LBM and BSA are: equation


Formula 2

where a=1.10 (men) or 1.07 (women), and b=128 (men) or 148 (women). equation


Formula 3

VBR
In contrast to SUV, VBR normalizes vessel wall FDG uptake to the circulating FDG concentration. The following equation was used to derive VBR from an averaged image of the last 30 minutes of the FDG scan: equation


Formula 4

Ki
Calculation of Ki by way of Patlak analysis has been described in detail elsewhere.16 Patlak analysis is a graphical method that, for each time frame, plots the concentration of FDG in the region of interest (CT) divided by the arterial plasma concentration of FDG (CP) on the y-axis and the integral of CP divided by CP on the x-axis. Assuming there is no dephosphorylation of FDG, the resulting Patlak plot becomes a straight line when the unmetabolized FDG concentration in tissue reaches steady state. The slope of this line is the influx rate, Ki, and we used data acquired from 40 to 120 minutes after injection to determine Ki.

Comparison of Quantification Methods
Ki was taken as the gold standard measurement of plaque FDG metabolism. The strength of correlation between Ki and SUV, Ki and VBR, KiPVC and SUVPVC, and KiPVC and VBRPVC were assessed using Pearson correlation coefficient test. Statistical significance was taken as P<0.05.

PVC
The geometric transfer matrix MR-based method, first described by Rousset et al,21 was used to correct the PVE of uptake into the carotid artery wall for each time frame. An in-house implementation of the Rousset algorithm used the ROIs defined on the HRMR, coregistered PET images, and the PET scanner resolution to calculate the contribution of tracer activity from each region to its surrounding regions, thus enabling partial volume-corrected FDG concentration to be estimated for each carotid vessel wall.

The difference between partial volume corrected and uncorrected FDG uptake was calculated for SUV, VBR, and Ki for each carotid vessel in each scan. To allow for comparison between quantification methods, the difference (DPVC) was expressed as a percentage of the uncorrected FDG uptake value as follows: equation


Formula 5

The mean difference and SD were then calculated for each of the 3 quantification methods.

PVC will affect the uptake values in a bidirectional manner; high uptake areas will increase and low uptake areas will decrease. This behavior will not be revealed in changes to the mean uptake value. Consequently, the mean absolute percentage difference was also calculated.

The paired t test was used to assess the difference between uncorrected and corrected values. P<0.05 was used to define statistical significance.

Reproducibility
To allow the reproducibility of the different quantification parameters to be compared, the percentage difference in FDG uptake between the 2 scans (DR) was calculated as follows: equation


Formula 6

The mean difference, mean absolute difference, and SDs were then calculated. The intraclass correlation coefficient statistic was used to assess the strength of correlation between FDG uptake for the 2 PET scans. An intraclass correlation coefficient value of 1 denotes perfect agreement, whereas values <1 indicate random or systematic differences between the 2 scans. Bland-Altman plots were also used to assess interscan variability.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMaterials and Methods
*Results
down arrowDiscussion
down arrowReferences
 
Comparison of Quantification Methods
Figure 2 shows the correlation between Ki and SUVBSA, VBR (Figure 2a) and KiPVC, and both SUVBSAPVC and VBRPVC (Figure 2b). The correlation between Ki and VBR (r=0.58, P<0.001) was stronger than between Ki and SUVBSA (r=0.46; P=0.014). Partial volume correction improved the correlations (KiPVC and VBRPVC: r=0.81, P<0.001; KiPVC and SUVBSAPVC: r=0.76, P<0.001). SUVBSA correlated better with Ki than both SUVW (r=0.35; P=0.07) and SUVLBM (r=0.43; P=0.022). SUVBSAPVC also correlated better with KiPVC than both SUVWPVC (r=0.67; P<0.001) and SUVLBMPVC (r=0.73; P<0.001).


Figure 2521393
View larger version (8K):
[in this window]
[in a new window]

 
Figure 2. Correlations between (a) Ki and both SUVBSA and VBR and (b) KiPVC and both SUVBSAPVC and VBRPVC.

PVC
The results are summarized in Table 1. Note that results are not given for SUVLBM and SUVW because the percentage changes will be the same as for SUVBSA. After applying PVC, the mean SUV increased statistically significantly by 0.05 (SD, 0.11). PVC did not result in a significant change in the mean of the other 2 parameters (VBR, Ki). The mean absolute percentage differences are higher than the corresponding mean percentage differences because of the bidirectional effect of PVC, which is illustrated in Figure 3 for 1 of the parameters (VBR); for a threshold uncorrected VBR value of 1.25, all 5 of the values above this threshold increase with PVC and 7 of the 9 values below it decrease with PVC. The range values in Table 1 show that PVC increased or decreased some uptake values by >50%.


View this table:
[in this window]
[in a new window]

 
Table 1. PVC of FDG Uptake Values in the Carotid Artery Wall


Figure 3521393
View larger version (23K):
[in this window]
[in a new window]

 
Figure 3. The effect of PVC on mean carotid artery VBR values.

Reproducibility
The reproducibility results are summarized in Table 2 and Figure 4. SUV showed superior reproducibility to both VBR and Ki. PVC degraded the reproducibility of all the uptake parameters, with SUVPVC being the least affected.


View this table:
[in this window]
[in a new window]

 
Table 2. Reproducibility of FDG Uptake Parameters for Carotid Artery Vessel Wall


Figure 4521393
View larger version (13K):
[in this window]
[in a new window]

 
Figure 4. Bland-Altman plots for 3 uptake parameters both with and without PVC (a to f). Box and whiskers plot showing the interscan variability of the different methods in percentage terms (g). The boxes represent the outer limits of the 25th and 75th percentiles. The whiskers represent the minimum and maximum values. {lozenge}=median value. For the box and whiskers plot SUV is given rather than individual SUVX because the results are independent of the normalization method.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMaterials and Methods
up arrowResults
*Discussion
down arrowReferences
 
This study reports on important areas of quantification that have not been addressed in previously published studies that have used FDG-PET to image inflammation in atherosclerotic vessels. First, this is the only study to our knowledge to correct FDG uptake in the arterial wall for PVE. The need for PVC to improve quantification of tracer concentration in small regions is well-established,17,18,21,22 and its application is highly relevant to FDG imaging of atherosclerotic plaques given their small size and proximity to FDG signal from the arterial lumen. In this study, PVC led to only a small increase in mean FDG uptake of 1% to 6%, depending on the quantification measurement used. However, this statistic hides the fact that high uptake values are increased with PVC but low uptake values usually decrease (Figure 3). Thus, the mean percentage change statistic is rather deceptive. It is better to express the effect of PVC in absolute percentage terms, in which case the change in uptake value was between 13% and 21%, depending on the quantification parameter used. Even this statistic does not clearly reveal that some values increased or decreased by >50% after PVC (Table 1). PVC also improved the correlation between influx rate (Ki) and the simplified methods SUV and VBR (Figure 2). These results suggest that PVC may significantly improve the quantification of inflammatory activity in individual plaques, but whether this will translate into a clinically meaningful difference remains to be seen.

Second, this study compares different methods of quantifying FDG uptake in the vessel wall. Many different methods of quantifying tissue FDG uptake have been proposed.27,28 When FDG-PET is used for oncological purposes, SUV is the most commonly used parameter. It is quick to calculate and does not rely on drawing blood samples from the patient. In oncology its use has been validated against more sophisticated "gold standard" methods of quantification such as Ki29–31. Because the use of FDG-PET for quantifying vascular wall inflammation is a relatively new concept, similar validation studies in patients with atherosclerosis until now have not been attempted. The results from this study show that normalizing SUV to BSA provides a better correlation with Ki than normalization using either LBM or body weight. The correlation of SUVBSA and Ki is not as strong as for another simplified method that normalizes vessel wall FDG uptake to the blood FDG concentration (VBR). As with calculation of SUV, estimation of VBR does not require blood sampling, but instead uses the scan data to determine the concentration of FDG in blood from an adjacent artery or vein, in this case the jugular vein. This normalization method is based on assuming that the jugular vein ROI value is proportional to the input function. The major weakness of this comparison of quantification methods is the lack of a histological "gold standard" measure of plaque inflammation to compare the quantification methods to. Unfortunately, human studies do not lend themselves toward this kind of study because of the difficulty in extracting tissue samples in a timely fashion. Therefore, an animal study would be the best way of examining this.

Last, this study reports on the reproducibility of combined MR and FDG-PET for quantifying vessel wall FDG uptake. The results are in broad agreement with the recently published study by Rudd et al,11 although there are a number of important methodological differences between the 2 studies: In this study all the patients had experienced recent strokes thought to be caused by the presence of carotid atheroma. Although Rudd et al reported on patients who had established but asymptomatic atherosclerosis, the uptake measure given by Rudd et al (whole vessel-to-blood ratio) differs from VBR used in this study. We used MR to provide anatomic coregistration, whereas Rudd et al used a combined PET/CT scanner. MR has several advantages over x-ray CT, including an absence of ionizing radiation exposure and, most importantly, clearer delineation of the vessel wall, allowing for plaque characterization, more accurate delineation of ROIs, and PVC. However, a combined PET/CT scanner provides anatomic and functional images in the same imaging session, which aids coregistration accuracy. The results from this study clearly show that the intertest reproducibility of FDG-PET for quantifying FDG uptake in the arterial wall depends on which quantification method is used. The data show that SUV is the most reproducible method for estimation of FDG uptake and the reproducibility of this parameter compares well with those obtained for other atherosclerosis imaging modalities such as MR,32 intravenous ultrasound,33 and CT.34 They also compare favorably to those from a reproducibility study of FDG uptake in tumors.35 VBR is less reproducible than SUV because of the extra variability introduced by normalizing to an image ROI value from the jugular vein. Ki is the least reproducible because it is obtained from the gradient of transformed data rather than the mean of multiple frames as in the case of SUV and VBR. Partial volume corrected parameters are less reproducible than their corresponding noncorrected measures. The accuracy of partial volume correction is known to be reduced by noise, inaccurate delineation of regions, and, in particular, inaccurate coregistration of PET and MR scans.23 The latter is likely to improve with the use of the combined PET/MR scanners that are currently in development.36 Nevertheless, SUVPVC performs reasonably well in terms of reproducibility.

In summary, we have shown that MR-based PVC is both feasible and important when quantifying FDG uptake in atherosclerotic vessels. Of the methods tested, SUV is the most reproducible method of quantifying FDG uptake in carotid artery vessel wall, and its correlation with Ki almost matches that of VBR. Of the simplified methods examined, it appears that SUVBSAPVC represents the best compromise between reproducible and accurate determination of FDG metabolism in carotid artery vessel wall. However, further studies are needed to confirm the accuracy of the different FDG parameters used in this study in quantifying inflammation. Ideally, such a study should look at both the relationship between the different parameters and the degree of plaque inflammation at a histological level and their accuracy in predicating future atherothrombotic events. If the results from such a study are positive, then FDG-PET could become a powerful clinical tool for both predicting stroke risk and guiding pharmacological and interventional therapy.


*    Acknowledgments
 
The authors acknowledge the assistance provided by the Stroke Unit nurses, and the Wolfson Brain Imaging Centre radiochemistry staff and radiographers.

Sources of Funding

This study was funded by a program grant from the British Heart Foundation (FG/03/013). This work was also supported by the Comprehensive Biomedical Research Centre grant to Cambridge University Hospitals National Health Service Foundation Trust and Cambridge University (Cardiovascular Theme).

Disclosures

Jonathan H. Gillard is a Consultant for GlaxoSmithKline. D.I., J.R.D., J.H.F.R., and P.L.W. are all supported by grants from the British Heart Foundation.

Received March 26, 2008; revision received May 11, 2008; accepted June 4, 2008.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMaterials and Methods
up arrowResults
up arrowDiscussion
*References
 
1. Davies MJ, Thomas AC. Plaque fissuring—the cause of acute myocardial infarction, sudden ischaemic death, and crescendo angina. Br Heart J. 1985; 53: 363–373.[Free Full Text]

2. Davies MJ. Stability and instability: Two faces of coronary atherosclerosis. The Paul Dudley White Lecture 1995. Circulation. 1996; 94: 2013–2020.[Free Full Text]

3. Jander S, Sitzer M, Schumann R, Schroeter M, Siebler M, Steinmetz H, Stoll G. Inflammation in high-grade carotid stenosis: A possible role for macrophages and T cells in plaque destabilization. Stroke. 1998; 29: 1625–1630.[Abstract/Free Full Text]

4. Ambrose JA, Winters SL, Arora RR, Eng A, Riccio A, Gorlin R, Fuster V. Angiographic evolution of coronary artery morphology in unstable angina. J Am Coll Cardiol. 1986; 7: 472–478.[Abstract]

5. Warburton EA, Gillard JH. Functional imaging of carotid atheromatous plaques. J Neuroimaging. 2006; 16: 293–301.[Medline] [Order article via Infotrieve]

6. Rudd JHF, Warburton EA, Fryer TD, Jones HA, Clark JC, Antoun N, Johnstrom P, Davenport AP, Kirkpatrick PJ, Arch BN, Pickard JD, Weissberg PL. Imaging atherosclerotic plaque inflammation with 18F-fluorodeoxyglucose positron emission tomography. Circulation. 2002; 105: 2708–2711.[Abstract/Free Full Text]

7. Davies JR, Rudd JHF, Fryer TD, Graves MJ, Clark JC, Kirkpatrick PJ, Gillard JH, Warburton EA, Weissberg PL. Identification of culprit lesions after transient ischemic attack by combined 18F-fluorodeoxyglucose positron-emission tomography and high-resolution magnetic resonance imaging. Stroke. 2005; 36: 2642–2647.[Abstract/Free Full Text]

8. Tawakol A, Migrino RQ, Hoffmann U, Abbara S, Houser S, Gewirtz H, Muller JE, Brady TJ, Fischman AJ. Noninvasive in vivo measurement of vascular inflammation with F-18 fluorodeoxyglucose positron emission tomography. J Nucl Cardiol. 2005; 12: 294–301.[CrossRef][Medline] [Order article via Infotrieve]

9. Tawakol A, Migrino RQ, Bashian GG, Bedri S, Vermylen D, Cury RC, Yates D, LaMuraglia GM, Furie K, Houser S, Gewirtz H, Muller JE, Brady TJ, Fischman AJ. In vivo 18F-Fluorodeoxyglucose positron emission tomography imaging provides a noninvasive measure of carotid plaque inflammation in patients. J Am Coll Cardiol. 2006; 48: 1818–1824.[Abstract/Free Full Text]

10. Ogawa M, Magata Y, Kato T, Hatano K, Ishino S, Mukai T, Shiomi M, Ito K, Saji H. Application of 18F-FDG PET for monitoring the therapeutic effect of antiinflammatory drugs on stabilization of vulnerable atherosclerotic plaques. J Nucl Med. 2006; 47: 1845–1850.[Abstract/Free Full Text]

11. Rudd JH, Myers KS, Bansilal S, Machac J, Rafique A, Farkouh M, Fuster V, Fayad ZA. 18Fluorodeoxyglucose positron emission tomography imaging of atherosclerotic plaque inflammation is highly reproducible: Implications for atherosclerosis therapy trials. J Am Coll Cardiol. 2007; 50: 892–896.[Abstract/Free Full Text]

12. Ogawa M, Ishino S, Mukai T, Asano D, Teramoto N, Watabe H, Kudomi N, Shiomi M, Magata Y, Iida H, Saji H. 18F-FDG accumulation in athorosclerotic plaques: Immunohistochemical and PET imaging study. J Nucl Med. 2004; 45: 1245–1250.[Abstract/Free Full Text]

13. Okane K, Ibaraki M, Toyoshima H, Sugawara S, Takahashi K, Miura S, Shimosegawa E, Kitamur J, Satoh T. 18F-FDG accumulation in atherosclerosis: Use of CT and MR co-registration of thoracic and carotid arteries. Eur J Nucl Med Mol Imaging. 2006; 33: 589–594.[CrossRef][Medline] [Order article via Infotrieve]

14. Arauz A, Hoyos L, Zenteno M, Mendoza R, Alexanderson E. Carotid plaque inflammation detected by 18F-fluorodeoxyglucose-positron emission tomography. Pilot study. Clin Neurol Neurosurg. 2007; 109: 409–412.[CrossRef][Medline] [Order article via Infotrieve]

15. Tahara N, Kai H, Ishibashi M, Nakaura H, Kaida H, Baba K, Hayabuchi N, Imaizumi T. Simvastatin attenuates plaque inflammation. J Am Coll Cardiol. 2006; 48: 1825–1831.[Abstract/Free Full Text]

16. Patlak CS, Blasberg RG. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab. 1985; 5: 584–590.[Medline] [Order article via Infotrieve]

17. Mazziotta JC, Phelps ME, Plummer D, Kuhl DE. Quantitation in positron emission computed tomography: 5. Physical-anatomical effects. J Comput Assist Tomogr. 1981; 5: 734–743.[Medline] [Order article via Infotrieve]

18. Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979; 3: 299–308.[Medline] [Order article via Infotrieve]

19. Glagov S, Weisenberg E, Zarins CK, Stankunavicius R, Kolettis GJ. Compensatory enlargement of human atherosclerotic coronary arteries. N Engl J Med. 1987; 316: 1371–1375.[Abstract]

20. Muller-Gartner HW, Links JM, Prince JL, Bryan RN, McVeigh E, Leal JP, Davatzikos C, Frost JJ. Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects. J Cereb Blood Flow Metab. 1992; 12: 571–583.[Medline] [Order article via Infotrieve]

21. Rousset OG, Ma Y, Evans AC. Correction for partial volume effects in PET: Principle and validation. J Nucl Med. 1998; 39: 904–911.[Abstract/Free Full Text]

22. Labbe C, Koepp M, Ashburner J, Spinks T, Richardson M, Duncan J, Cunningham V. Quantitative functional brain imaging with positron emission tomography. In: Carson RE HP, Daube-Witherspoon M, eds. San Diego, CA: Academic Press; 1998: 59–66.

23. Meltzer CC, Kinahan PE, Greer PJ, Nichols TE, Comtat C, Cantwell MN, Lin MP, Price JC. Comparative evaluation of MR-based partial volume correction schemes for PET. J Nucl Med. 1999; 40: 2053–2065.[Abstract/Free Full Text]

24. Kinahan PE, Rogers JG. Analytic 3D image reconstruction using all detected events. IEEE Trans Nucl Sci. 1989; 36: 964–968.[CrossRef]

25. Hallynck TH, Soep HH, Thomis JA, Boelaert J, Daneels R, Dettli L. Should clearance be normalised to body surface or to lean body mass? Br J Clin Pharmacol. 1981; 11: 523–526.[Medline] [Order article via Infotrieve]

26. Mosteller RD. Simplified calculation of body-surface area. N Engl J Med. 1987; 317: 1098.[Medline] [Order article via Infotrieve]

27. Hallett WA. Quantification in clinical fluorodeoxyglucose positron emission tomography. Nucl Med Commun. 2004; 25: 647–650.[CrossRef][Medline] [Order article via Infotrieve]

28. Weber WA, Schwaiger M, Avril N. Quantitative assessment of tumor metabolism using FDG-PET imaging. Nucl Med Biol. 2000; 27: 683–687.[CrossRef][Medline] [Order article via Infotrieve]

29. Graham MM, Peterson LM, Hayward RM. Comparison of simplified quantitative analyses of FDG uptake. Nucl Med Biol. 2000; 27: 647–655.[CrossRef][Medline] [Order article via Infotrieve]

30. Freedman NM, Sundaram SK, Kurdziel K, Carrasquillo JA, Whatley M, Carson JM, Sellers D, Libutti SK, Yang JC, Bacharach SL. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans. Eur J Nucl Med Mol Imaging. 2003; 30: 46–53.[CrossRef][Medline] [Order article via Infotrieve]

31. Krak NC, van der Hoeven JJ, Hoekstra OS, Twisk JW, van der Wall E, Lammertsma AA. Measuring [18F]FDG uptake in breast cancer during chemotherapy: Comparison of analytical methods. Eur J Nucl Med Mol Imaging. 2003; 30: 674–681.[Medline] [Order article via Infotrieve]

32. Varghese A, Crowe LA, Mohiaddin RH, Gatehouse PD, Yang GZ, Firmin DN, Pennell DJ. Inter-study reproducibility of 3D volume selective fast spin echo sequence for quantifying carotid artery wall volume in asymptomatic subjects. Atherosclerosis. 2005; 183: 361–366.[CrossRef][Medline] [Order article via Infotrieve]

33. Hagenaars T, Gussenhoven EJ, van Essen JA, Seelen J, Honkoop J, van der Lugt A. Reproducibility of volumetric quantification in intravascular ultrasound images. Ultrasound Med Biol. 2000; 26: 367–374.[CrossRef][Medline] [Order article via Infotrieve]

34. Budoff MJ, Achenbach S, Blumenthal RS, Carr JJ, Goldin JG, Greenland P, Guerci AD, Lima JA, Rader DJ, Rubin GD, Shaw LJ, Wiegers SE. Assessment of coronary artery disease by cardiac computed tomography: A scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation. 2006; 114: 1761–1791.[Free Full Text]

35. Weber WA, Ziegler SI, Thodtmann R, Hanauske AR, Schwaiger M. Reproducibility of metabolic measurements in malignant tumors using FDG PET. J Nucl Med. 1999; 40: 1771–1777.[Abstract/Free Full Text]

36. Schlemmer H, Pichler B, Claussen C, Wienhard K, Heiss W, Schmand M, Nahmias C, Townsend D Simultaneous MR/PET for brain imaging: First patient scans. J Nucl Med. 2007; 48S: 45P.




This article has been cited by other articles:


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
T. Y. Tang, K. H. Muller, M. J. Graves, Z. Y. Li, S. R. Walsh, V. Young, U. Sadat, S. P.S. Howarth, and J.H. Gillard
Iron Oxide Particles for Atheroma Imaging
Arterioscler Thromb Vasc Biol, July 1, 2009; 29(7): 1001 - 1008.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. H.F. Rudd, F. Hyafil, and Z. A. Fayad
Inflammation Imaging in Atherosclerosis
Arterioscler Thromb Vasc Biol, July 1, 2009; 29(7): 1009 - 1016.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
40/1/86    most recent
STROKEAHA.108.521393v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Izquierdo-Garcia, D.
Right arrow Articles by Warburton, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Izquierdo-Garcia, D.
Right arrow Articles by Warburton, E. A.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Medline Plus Health Information
*MRI Scans
*Nuclear Scans
Hazardous Substances DB
*POTASSIUM
Related Collections
Right arrow Imaging
Right arrow Nuclear cardiology and PET
Right arrow Carotid Stenosis
Right arrow Computerized tomography and Magnetic Resonance Imaging
Right arrow PET and SPECT