| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Stroke. 2009;40:754.)
© 2009 American Heart Association, Inc.
Original Contributions |
From Duke University (D.M.F.), Durham, NC; Duke University School of Medicine (D.G.S.), Durham, NC; Durham County Emergency Medical Services (B.K.U.), Durham, NC; and the Department of Medicine (Neurology; L.B.G.), Duke Stroke Center, Center for Clinical Health Policy Research, Duke University and Durham VAMC, Durham, NC.
Correspondence to Larry B. Goldstein, MD, Box 3651, Duke University Medical Center, Durham, NC 27710. E-mail golds004{at}mc.duke.edu
| Abstract |
|---|
|
|
|---|
Methods— A 1-hour interactive educational presentation on the use of the CPSS was conducted for paramedics transporting patients to an academic medical center. Patients with stroke/transient ischemic attack (TIA) were identified retrospectively from paramedic records and were compared with the hospitals prospective stroke registry for the year before and after the training.
Results— There were 154 patients with suspected stroke/transient ischemic attack identified (56% women, 53% white, 44% black, mean age 67±16 years). There was no difference in paramedics use of the CPSS (37.5% versus 23.8%, P=0.123) or accuracy of stroke/TIA patient identification (40.5% versus 38.9%, P=0.859) before and after training. Of responsive patients identified by paramedics as having a stroke/TIA, 57% had an abnormality in at least one CPSS item with no effect on on-scene time (17±6 minutes with a normal versus 18±6 minutes with an abnormal CPSS, P=0.492). Those with a final diagnosis of stroke/TIA (n=61, 40%) more frequently had at least one abnormal CPSS item (70% versus 30%, P=0.008, sensitivity 0.71, specificity 0.52) with 49% of patients with an abnormality having a discharge diagnosis of stroke/TIA.
Conclusions— Paramedic training in the CPSS, or its use, had no impact on the accuracy of their identification of patients with stroke/TIA or on-scene time.
Key Words: diagnosis emergency services stroke
| Introduction |
|---|
|
|
|---|
A variety of systems have been developed to aid emergency medical technicians and paramedics in successfully identifying patients with stroke. The American Stroke Association recommends EMS use algorithms such as the Los Angeles Prehospital Stroke Scale or the Cincinnati Prehospital Stroke Scale (CPSS) for this purpose.10 The CPSS evaluates facial droop, arm drift, and speech clarity. Previous work has found good agreement between physicians and paramedics using the CPSS in an emergency department setting.11 There are, however, only limited data assessing its performance when used by EMS personnel in the field. Our primary aim was to assess the impact of routine training and use of the CPSS on the accuracy of EMS personnels identification of patients with stroke and on-scene time.
| Subjects and Methods |
|---|
|
|
|---|
A 1-hour long interactive educational presentation for DC-EMS personnel was conducted in November 2004 focusing on stroke recognition and the use of the CPSS. The session was a component of standard monthly continuing education required for all EMS personnel. Written materials describing the use of the CPSS were provided and the session videotaped for later review by DC-EMS personnel.
Subjects
Durham County EMS uses standard codes to indicate the reason for transport for all patients. All patients transported by DC-EMS to Duke University Medical Center and coded by EMS as having a possible stroke or transient ischemic attack (TIA) were identified retrospectively by review of computerized and paper-based paramedic records for the year before and after training regardless of whether or not an abnormality was noted for a CPSS item. These records were then compared with the hospitals prospective stroke registry for the same period. The stroke registry includes all patients admitted to the study hospital with a discharge diagnosis of stroke or TIA. Those not in the registry had other conditions. The hospital-based stroke diagnosis is based on standard clinical criteria including the results of neuroimaging studies. Patients identified by EMS as being "unresponsive" were excluded.
Data Analysis
EMS report forms and paramedic narratives were evaluated for documentation of the CPSS. Documentation of the presence or absence of facial droop, speech deficit, and arm drift were considered as evidence of having completed the CPSS if the use of the scale was not explicitly noted. Additionally, other means of stroke screening, including documentation of grip strength, visual abnormalities, and numbness or tingling, were recorded to explore their impact on the accuracy of the assessment. If no paramedic narrative was available, it was assumed no elements of the CPSS were performed. The paramedics identification was compared with the patients final diagnosis in the hospital stroke registry, which reflects the results of routine clinical, laboratory, and radiographic evaluations. Final hospital-based diagnoses of stroke or TIA were considered together for the analysis, because it would not be possible for a paramedic to make this distinction. Symptom onset, EMS activation, EMS on-scene, and emergency department arrival times were also recorded. EMS response level to and from the scene as emergent (with lights and sirens) or routine was noted.
Data were recorded in a secure computerized database for analysis. Fisher exact tests were used to assess the statistical significance of differences before and after training. Sensitivity, specificity, and positive and negative predictive values were determined in comparison to the final hospital-based diagnosis of stroke or TIA. All statistical analyses were performed using SPSS for Macintosh computers (SPSS Inc, Chicago, Ill). Means for continuous variables were calculated (±1 SD) and compared with a t test. The Duke Institutional Review Board approved the study.
| Results |
|---|
|
|
|---|
The differences in paramedics use of the CPSS (37.5% versus 23.8%, P=0.123) or in the accuracy of the paramedics stroke/TIA identification (40.5% versus 38.9%, P=0.859) before as compared with after training were not significant.
Of responsive patients with a paramedic-identified stroke or TIA, 57% had an abnormality in at least one CPSS item. Those with a final diagnosis of stroke or TIA (n=61 [40%]) more frequently had at least one abnormal CPSS item (70% versus 30% with no CPSS abnormality, P=0.008; sensitivity 0.71, 95% CI 0.58 to 0.80; specificity 0.52, 95% CI 0.42 to 0.62). In cases in which paramedics documented assessment of all elements of the CPSS, the positive predictive value of having at least one abnormality was 0.52, negative predictive value 0.64, sensitivity 0.74, and specificity 0.41 (Table).
|
Alternative methods of stroke screening using elements not included in the CPSS were often documented (51% [n=79]) with 32% of patients presenting with a non-CPSS abnormality. These included reduced grip strength (12% abnormal [n=19]), visual deficits (14% abnormal [n=22]), or numbness or tingling (13% abnormal [n=20]). No patient with a negative CPSS had documented abnormalities in grip strength. Patients with a negative CPSS were equally likely to have documented normal vision or a visual abnormality (5% abnormal, 5% normal). Patients with a negative CPSS more frequently had documented numbness or tingling (8% abnormal, 3% normal). Of the total patient population, 68% had an abnormality in at least one component of the CPSS, grip strength, vision, numbness, or tingling. Of patients with a final diagnosis of stroke or TIA, 94% had an abnormality in at least one of these elements (sensitivity 0.94, specificity 0.20, positive predictive value 0.47, negative predictive value 0.83). For patients with a final diagnosis of stroke or TIA for whom the data were recorded, 11.5% had an abnormality of grip strength, vision, or numbness/tingling but a normal CPSS (16% of those with a noncerebrovascular final diagnosis and a normal CPSS had one of these abnormalities).
On-scene time for patients with stroke/TIA did not vary significantly before as compared with after the training in the use of the CPSS (19±6 versus 17±6 minutes, mean±SD; P=0.08). In addition, the presence of a documented CPSS item abnormality had no significant effect on paramedics on-scene time (17±6 minutes with a normal CPSS versus 18±6 minutes with an abnormal CPSS, P=0.492). There was no significant difference in paramedics response to the scene with lights and sirens (58% versus 50.7%, P=0.305) or urgent transport to the hospital before and after training (16.0% versus 19.9%, P=0.479).
| Discussion |
|---|
|
|
|---|
Prior work found that the CPSS is reliable and reproducible in an emergency department setting with a coefficient of correlation of 0.89 (95% CI, 0.87 to 0.92) between physicians and EMS personnel.11 In the emergency department, the CPSS had a 0.66 sensitivity (95% CI, 0.49 to 0.80) and 0.87 specificity (95% CI, 0.80 to 0.92). Our study found similar sensitivity (0.71; 95% CI, 0.58 to 0.80) but somewhat poorer specificity (0.52; 95% CI, 0.42 to 0.62) when used in the field. Given the diversity of their call volume, this may be due to the reduced frequency with which EMS personnel practice stroke screening in the field or may be due to other factors, including differences in patient populations between the 2 studies. Whether improvements can be achieved with more extensive training or through ongoing performance improvement programs requires further study.
Although based on an exploratory analysis, our data suggest that the sensitivity of EMS stroke/TIA screening increases greatly when assessments of grip strength, visual deficits, and numbness and tingling are added to the CPSS (11.5% of patients with a final diagnosis of stroke or TIA had a normal CPSS but one of these other abnormalities). This increased sensitivity, however, comes at the cost of a great decrease in specificity. If the goal of EMS stroke screening is to identify the greatest number of patients with potential stroke/TIA, increasing screening elements is of benefit. Should such a screening measure be used for activating in-hospital stroke teams, the number of false-positive cases may, however, be unsustainably high. If prehospital screening is to be used for costly transport diversion, specificity must improve beyond the 52% found in our study. The CPSS may need to be re-evaluated as a key prehospital stroke screening tool, especially because EMS systems are increasingly relied on to triage patients with suspected stroke/TIA.
Given that this retrospective study relied on EMS documentation as an indication of performance of stroke screening measures, our results may be biased if documentation was incomplete or inadequate. This may be particularly true for the non-CPSS measures. As a system, however, DC-EMS encourages clear documentation of key screening steps, and there was high consistency between paramedic narrative reporting styles.
Further study of the CPSS and similar stroke scales in the field will be necessary to optimize their use in helping to identify and triage patients with suspected stroke or TIA. Of note, the EMS system studied in this report recently implemented a program in which paramedics directly contact cardiac catheterization laboratory personnel for patients with symptoms suggestive of an acute coronary syndrome and having ST elevation on 12-lead electrocardiogram. This was successful in reducing the time to reperfusion treatment.12 A similar system may be possible for patients with acute stroke. Prospective studies carried out in the prehospital setting should further evaluate the CPSS and additional stroke screening tools, specifically including the elements associated with increased sensitivity that were identified in our exploratory analysis.
| Acknowledgments |
|---|
This work was supported by an American Stroke Association student scholarship award.
Disclosures
None.
Received July 9, 2008; revision received July 23, 2008; accepted July 25, 2008.
| References |
|---|
|
|
|---|
2. Kothari R, Jauch E, Broderick J, Brott T, Sauerbeck L, Khoury J, Liu T. Acute stroke: delays to presentation and emergency department evaluation. Ann Emerg Med. 1999; 33: 3–8.[Medline] [Order article via Infotrieve]
3. Lacy C, Suh D, Bueno M, Kostis J, for the Stroke Collaborative Study Group. Delay in presentation and evaluation for acute stroke: Stroke Time Registry for Outcomes Knowledge and Epidemiology (STROKE). Stroke. 2001; 32: 63–69.
4. Rosamond W, Gorton R, Hinn A, Hohenhaus S, Morris D. Rapid response to stroke symptoms: the Delay in Accessing Stroke Healthcare (DASH) study. Acad Emerg Med. 1998; 5: 45–51.[Medline] [Order article via Infotrieve]
5. Schroeder E, Rosamond W, Morris D, Evenson K, Hinn A. Determinants of use of emergency medical services in a population with stroke symptoms: the Second Delay in Accessing Stroke Healthcare (DASH II) study. Stroke. 2000; 31: 2591–2596.
6. Wein T, Staub L, Felberg R, Hickenbottom SL, Chan W, Grotta JC, Demchuck AM, Groff J, Bartholomew LK, Morgenstern LB. Activation of emergency medical services for acute stroke in a nonurban population: the TLL Temple Foundation Stroke Project. Stroke. 2000; 31: 1925–1928.
7. Bratina P, Greenberg L, Pasteur W, Grotta J. Current emergency department management of stroke in Houston, Texas. Stroke. 1995; 26: 409–414.
8. Menon S, Pandey D, Morganstern L. Critical factors in determining access to acute stroke care. Neurology. 1998; 51: 427–432.
9. Morris D, Rosamond W, Hinn A, Gorton R. Time delays in accessing stroke care in the emergency department. Acad Emerg Med. 1999; 6: 218–223.[Medline] [Order article via Infotrieve]
10. Schwamm L, Pancioli A, Acker JE, Goldstein LB, Zorowitz RD, Shephard TJ, Moyer P, Gorman M, Johnston C, Smith R, Federspeil W, Horton KB, Magnis E, Adams RJ. Recommendations for the establishment of stroke systems of care: recommendations from the American Stroke Associations Task Force on the Development of Stroke Systems. Stroke. 2005; 36: 690–703.
11. Kothari R, Pancioli A, Liu T, Brott T, Broderick J. Cincinnati Prehospital Stroke Scale: reproducibility and validity. Ann Emerg Med. 1999; 33: 373–378.[CrossRef][Medline] [Order article via Infotrieve]
12. Strauss DG, Sprague PQ, Underhill K, Maynard C, Adams GL, Kessenich A, Sketch MH Jr, Berger PB, Marcozzi D, Granger CB, Wagner GS. Paramedic transtelephonic communication to cardiologist of clinical and electrocardiographic assessment for rapid reperfusion of ST-elevation myocardial infarction. J Electrocardiol. 2007; 40: 265–270.[CrossRef][Medline] [Order article via Infotrieve]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2009 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |