Submitted on March 15, 2003
From the Cerebral Blood Flow Laboratory and Brain Injury Research Center (T.C.G., P.V., B.R., C.H., N.A.M.), Division of Neurosurgery, David Geffen School of Medicine, University of California at Los Angeles, and the Department of Neurosurgery (J.F.S.), Rambam Medical Center, Technion, B. Rappaport Faculty of Medicine, Haifa, Israel. * To whom correspondence should be addressed. E-mail: neilmartin{at}mednet.ucla.edu.
Background and Purpose--We sought to evaluate a new, angle-independent ultrasonic device for assessment of blood flow volume (BFV) in the internal carotid artery (ICA). Methods--Nineteen patients and 4 healthy volunteers were enrolled in a comparative study conducted in the Care Unit of the Division of Neurosurgery at UCLA Medical Center. All patients had been admitted because of severe brain injury: 15 patients with severe head trauma (Glasgow Coma Scale score Results--Hemispheric CBF values showed a close and linear correlation with BFV measurements (r=0.76, P<0.0001). Global CBF values showed a higher correlation with the total BFV value obtained from both ICAs (r=0.84, P<0.0001). With 37 mL · min-1 · 100 g-1 as a cutoff value for the ischemic range, a BFV value of 220 mL/min would yield a positive predictive value of 91.7% and a negative predictive value of 82.6% (sensitivity 73.3%, specificity 95%). Conversely, BFV sensitivity and specificity were 60% and 96%, respectively, for the hyperemic range defined by a CBF value >55 mL · min-1 · 100 g-1 (positive predictive value of 85.7% and negative prediction value of 85.7%). Conclusions--BFV measurements with this new technology proved to accurately correlate with CBF values evaluated by the 133xenon-clearance technique. These results support the implementation of this technique for bedside assessment of cerebral hemodynamics in critically ill neurosurgical patients.
Accepted on April 8, 2003
Assessment of Cerebral Blood Flow by Means of Blood-Flow-Volume Measurement in the Internal Carotid Artery. Comparative Study With a 133Xenon Clearance Technique
J. F. Soustiel MD;
8) and 4 patients with subarachnoid hemorrhage due to aneurysm rupture. In all patients and subjects, cerebral blood flow (CBF) values obtained with the 133xenon-clearance technique were compared with BFV measurements in the ipsilateral ICA.
This article has been cited by other articles:
![]() |
O. Nevo, J. F. Soustiel, and I. Thaler Cerebral blood flow is increased during controlled ovarian stimulation Am J Physiol Heart Circ Physiol, December 1, 2007; 293(6): H3265 - H3269. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.O. Oktar, C. Yucel, D. Karaosmanoglu, K. Akkan, H. Ozdemir, N. Tokgoz, and T. Tali Blood-Flow Volume Quantification in Internal Carotid and Vertebral Arteries: Comparison of 3 Different Ultrasound Techniques with Phase-Contrast MR Imaging. AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 363 - 369. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Wintermark, M. Sesay, E. Barbier, K. Borbely, W. P. Dillon, J. D. Eastwood, T. C. Glenn, C. B. Grandin, S. Pedraza, J.-F. Soustiel, et al. Comparative Overview of Brain Perfusion Imaging Techniques Stroke, September 1, 2005; 36(9): e83 - e99. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Hendrikse, A. F. van Raamt, Y. van der Graaf, W. P. T. M. Mali, and J. van der Grond Distribution of Cerebral Blood Flow in the Circle of Willis Radiology, April 1, 2005; 235(1): 184 - 189. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. E. Heissler, K. Konig, and E. Rickels Assessment of Cerebral Blood Flow by Means of Blood-Flow-Volume Measurement Stroke, December 1, 2003; 34 (12): e239 - e239. [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |