Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Published Online
on October 2, 2003

Stroke. 2003
Published online before print October 2, 2003, doi: 10.1161/01.STR.0000092490.21761.7C
A more recent version of this article appeared on November 1, 2003
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
34/11/e222    most recent
01.STR.0000092490.21761.7Cv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Related Collections
Right arrow Angioplasty and Stenting
Right arrow Other Research

Submitted on May 28, 2003
Accepted on July 8, 2003

Wall Mechanics of the Stented Extracranial Carotid Artery

Hélène Vernhet MD, PhD; Beatrix Jean MD; Stephan Lust MD; Jean Pierre Laroche MD; Alain Bonafé MD; Jean Paul Sénac MD; I. Quéré MD, PhD; and Michel Dauzat MD, PhD*

From the Laboratory of Cardiovascular Physiology, Montpellier I University, Faculty of Medicine, Nimes, France (H.V., J.P.S., M.D.), and Departments of Neuroradiology (B.J., S.L., A.B., I.Q.) and Vascular Medicine (J.P.L.), Montpellier University Hospital, Montpellier Cedex, France.

* To whom correspondence should be addressed. E-mail: dauzat{at}univ-montp1.fr.

Background and Purpose--Abrupt compliance changes and concomitant nonlaminar flow patterns may contribute to endothelial dysfunction and subsequent neointimal thickening. The aim of this study was to test the feasibility of wall mechanics measurement using B-mode ultrasound image analysis by dedicated software in the stented human carotid artery.

Methods--Carotid Wallstents (Schneider) were placed in the extracranial carotid arteries of 15 patients. B-mode ultrasound examination was performed with a 7.5-MHz probe on the carotid artery upstream; at the proximal, mid, and distal stent levels; downstream from the stent; and on the contralateral internal and common carotid arteries. Carotid diameter (d) and systolic diameter changes ({Delta}d) were measured with a dedicated image processing system (IÔ version 3.1, IÔDP), while pulse blood pressure ({Delta}P) was measured. Diameter compliance (Cd) and distensibility coefficient (DC) were calculated as Cd=2{Delta}d/{Delta}P and DC=2{Delta}d/{Delta}P/d and compared between measurement sites.

Results--The evaluation could be completed in 8 of 15 patients. Compliance was significantly lower at the proximal, mid, and distal stent levels (27.77±1.11, 27.38±1.08, 27.38±1.09x10-3 mm · kPa-1) than upstream (103.3±36.7x10-3 mm · kPa-1), downstream (91.5±41.3x10-3 mm · kPa-1), or on the contralateral internal (87.6±28x10-3 mm · kPa-1) and common (149.3±47.6x10-3 mm · kPa-1) carotid arteries.

Conclusions--Stenting of the extracranial carotid artery induces a compliance mismatch between the native and the stented artery.


Key words: carotid arteries • compliance • stents