Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Published Online
on February 12, 2004

Stroke. 2004
Published online before print February 12, 2004, doi: 10.1161/01.STR.0000116102.15636.65
A more recent version of this article appeared on March 1, 2004
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
35/3/687    most recent
01.STR.0000116102.15636.65v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shiogai, T.
Right arrow Articles by Furuhata, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shiogai, T.
Right arrow Articles by Furuhata, H.
Right arrowPubmed/NCBI databases
*Substance via MeSH
Medline Plus Health Information
*Brain Diseases
Related Collections
Right arrow Brain Circulation and Metabolism
Right arrow Doppler ultrasound, Transcranial Doppler etc.

Submitted on August 30, 2003
Accepted on November 4, 2003

Comparison of Transcranial Brain Tissue Perfusion Images Between Ultraharmonic, Second Harmonic, and Power Harmonic Imaging

Toshiyuki Shiogai MD*; Natsuko Takayasu MD; Toshiki Mizuno MD; Masanori Nakagawa MD; and Hiroshi Furuhata MD, PhD

From the Department of Clinical Neurosciences, Kyoto Takeda Hospital, Kyoto (T.S.); Department of Neurology, Kyoto Prefectural University of Medicine, Kyoto (N.T., T.M., M.N.); and Medical Engineering Laboratory, Tokyo Jikei University School of Medicine, Tokyo (H.F.), Japan.

* To whom correspondence should be addressed. E-mail: shiogait{at}pop11.odn.ne.jp.

Background and Purpose--To clarify optimal brain tissue perfusion images visualized by transcranial ultrasound harmonic imaging, we compared gray-scale integrated backscatter (IBS) images of new ultraharmonic imaging (UHI) and conventional second harmonic imaging (SHI) with power harmonic imaging (PHI) (harmonic B-mode with harmonic power Doppler images) in 10 patients with and 4 without a temporal skull.

Methods--Using a SONOS 5500 (Philips), we evaluated transient response images taken after a bolus Levovist injection at a horizontal diencephalic plane via temporal windows. Based on transmitting/receiving frequencies (MHz), 4 imaging procedures using an S3 transducer (SHI2.6 [1.3/2.6], UHI [1.3/3.6], PHI2.6 [1.3/2.6], and PHI3.2 [1.6/3.2]) and 2 imaging procedures using an S4 transducer (SHI3.6 [1.8/3.6] and PHI3.6 [1.8/3.6]) were compared in terms of size and location, peak intensity (PI), contrast area demarcation, and background image quality.

Results--In intact skull cases, gray-scale imaging tended to show larger contrast areas than PHI. A large contrast area was most frequently observed in SHI2.6 images, despite there being more high-PI cases in UHI. No contrast area with unclear background was observed in a few cases. In craniectomized cases, all contrast images tended to have large and high PI compared with the intact skull cases. PHI, particularly PHI3.6, demonstrated sharper demarcation and a clearer background than gray-scale imaging.

Conclusions--Transcranial gray-scale SHI using a low receiving frequency of 2.6 MHz is the superior method. PHI identifies contrast area localization better than gray-scale imaging and is particularly suitable for intraoperative and postoperative cases.


Key words: contrast media • perfusion, brain • imaging techniques • ultrasonography, Doppler, color, transcranial