Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carter, L. P.
Right arrow Articles by Bro, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carter, L. P.
Right arrow Articles by Bro, W. J.

Stroke, Vol 12, 513-518, Copyright © 1981 by American Heart Association


ARTICLES

Cortical blood flow: thermal diffusion vs isotope clearance

LP Carter, R Erspamer and WJ Bro

A thermal diffusion flow probe incorporating a Peltier stack has been found to give a quantitative dynamic assessment of cortical blood flow in both the laboratory and clinical settings. Further calibration characteristics of the probe were evaluated by correlation with the fast component of Xe133 clearance in cats. The correlation has some linear characteristics but is better defined by the equation: CBFp = phi(1/delta V - 1/delta Vo) Where CBFp is flow in ml/100 g/min, delta V is the voltage difference of the thermocouples, and delta Vo is the voltage difference of the thermocouples with no flow, which was 342.8 +/- 12.9 microv. Phi describes the characteristics of the probe and was determined to be 52,431.2 +/- 4796.3. The average deviation of the calculated curve from the experimental data points was +/- 6.3. The calculated phi differed markedly from the mean when Xe133 fast component flows were less than 35 ml/100 g/min. This is evidence that CBF as measured by Xe133 clearance analyzed by the bicompartmental technique loses accuracy at lower flows. The thermal diffusion flow probe is a good device for evaluation of flow in acute ischemia models since it can delineate abrupt flow variations. Theoretically the flow probe can accurately measure flow at ischemic levels.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. Kamiya, G. Watanabe, T. Kanamori, N. Ishikawa, T. Terada, and K. Kawakami
Instant myocardial blood flow monitor: its calibration and assessment of flow capacity of the intracoronary shunt tube
Ann. Thorac. Surg., July 1, 2004; 78(1): 167 - 172.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Kamiya, G. Watanabe, T. Doi, T. Saito, M. Takahashi, S. Tomita, T. Tsukioka, and T. Kanamori
Coronary active perfusion system can maintain myocardial blood flow and tissue oxygenation
Eur. J. Cardiothorac. Surg., September 1, 2002; 22(3): 410 - 414.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Kamiya, G. Watanabe, T. Saito, T. Doi, S. Tomita, H. Ohtake, and T. Kanamori
Real-time and continuous monitoring of myocardial blood flow using a thermal diffusion method
Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 748 - 752.
[Abstract] [Full Text] [PDF]