Stroke, Vol 23, 1577-1582, Copyright © 1992 by American Heart Association
M Kaps, G Seidel, T Bauer and B Behrmann
BACKGROUND: Anatomic variety and difficult accessibility of the
vertebrobasilar arteries pose considerable problems to conventional
ultrasound. We evaluated the diagnostic potential of transcranial color-
coded sonography in the distal part of this system. METHODS: We insonated
the intracranial section of the vertebrobasilar arteries through the
foramen magnum window in 24 healthy individuals using a Doppler color flow
imaging system in connection with a 2.5-MHz sector transducer. Magnetic
resonance images in special inclination planes were performed and compared
with the color-coded duplex images in five cases. RESULTS: The B-mode image
of the craniocervical junction and the intracranial parenchymal structures
in addition to the color-coded blood flow allowed an unambiguous
identification of the vertebrobasilar arteries (vertebral artery, 96%;
basilar artery, 79%; and posterior inferior cerebellar artery, 50%). Blood
flow velocities were measured considering the insonation angles: vertebral
arteries, 50/24 cm/sec (30 degrees); basilar artery, 59/28 cm/sec (4
degrees); and posterior inferior cerebellar artery, 56/30 cm/sec (20
degrees) [peak systolic/end diastolic blood flow velocity (mean angle
correction)]. CONCLUSIONS: Transcranial color-coded sonography enables
accurate identification and differentiation of the intracranial
vertebrobasilar arteries and improves accuracy of Doppler measurements. It
may prove useful for evaluation of tortuosity and for hemodynamic studies
in this vascular territory.
ARTICLES
Imaging of the intracranial vertebrobasilar system using color-coded ultrasound
Department of Neurology, Justus-Liebig Universitat Giessen, FRG.
This article has been cited by other articles:
![]() |
E. Bartels Evaluation of Arteriovenous Malformations (AVMs) With Transcranial Color-Coded Duplex Sonography: Does the Location of an AVM Influence Its Sonographic Detection? J. Ultrasound Med., November 1, 2005; 24(11): 1511 - 1517. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Zunker, H. Wilms, J. Brossmann, D. Georgiadis, S. Weber, and G. Deuschl Echo Contrast-Enhanced Transcranial Ultrasound: Frequency of Use, Diagnostic Benefit, and Validity of Results Compared With MRA Stroke, November 1, 2002; 33(11): 2600 - 2603. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Stolz, M. Nuckel, I. Mendes, T. Gerriets, and M. Kaps Vertebrobasilar Transcranial Color-Coded Duplex Ultrasonography: Improvement with Echo Enhancement AJNR Am. J. Neuroradiol., June 1, 2002; 23(6): 1051 - 1054. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Schulte-Altedorneburg, D. W. Droste, V. Popa, W. A. Wohlgemuth, M. Kellermann, D. G. Nabavi, L. Csiba, and E. B. Ringelstein Visualization of the Basilar Artery By Transcranial Color-Coded Duplex Sonography : Comparison With Postmortem Results Stroke, May 1, 2000; 31(5): 1123 - 1127. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L Turner and P. J Kirkpatrick Detection of intracranial aneurysms with unenhanced and echo contrast enhanced transcranial power Doppler J. Neurol. Neurosurg. Psychiatry, April 1, 2000; 68(4): 489 - 495. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. W. Droste, R. Jurgens, S. Weber, R. Tietje, and E. B. Ringelstein Benefit of Echocontrast-Enhanced Transcranial Color-Coded Duplex Ultrasound in the Assessment of Intracranial Collateral Pathways Stroke, April 1, 2000; 31(4): 920 - 923. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Stolz, M. Kaps, A. Kern, and W. Dorndorf Frontal Bone Windows for Transcranial Color-Coded Duplex Sonography Stroke, April 1, 1999; 30(4): 814 - 820. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gerriets, E. Stolz, B. Modrau, I. Fiss, G. Seidel, and M. Kaps Sonographic monitoring of midline shift in hemispheric infarctions Neurology, January 1, 1999; 52(1): 45 - 45. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Baumgartner, H. P. Mattle, and G. Schroth Assessment of >=50% and <50% Intracranial Stenoses by Transcranial Color-Coded Duplex Sonography Stroke, January 1, 1999; 30(1): 87 - 92. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Baumgartner, M. Arnold, F. Gonner, I. Staikow, C. Herrmann, A. Rivoir, and R. M. Muri Contrast-Enhanced Transcranial Color-Coded Duplex Sonography in Ischemic Cerebrovascular Disease Stroke, December 1, 1997; 28(12): 2473 - 2478. [Abstract] [Full Text] |
||||
![]() |
G. Seidel and M. Kaps Harmonic Imaging of the Vertebrobasilar System Stroke, August 1, 1997; 28(8): 1610 - 1613. [Abstract] [Full Text] |
||||
![]() |
R. W. Baumgartner, A. C. Nirkko, R. M. Muri, and F. Gonner Transoccipital Power-Based Color-Coded Duplex Sonography of Cerebral Sinuses and Veins Stroke, July 1, 1997; 28(7): 1319 - 1323. [Abstract] [Full Text] |
||||
![]() |
R. W. Baumgartner, C. Schmid, and I. Baumgartner Comparative Study of Power-Based Versus Mean Frequency-Based Transcranial Color-Coded Duplex Sonography in Normal Adults Stroke, January 1, 1996; 27(1): 101 - 104. [Abstract] [Full Text] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1992 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |