Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 1995;26:1053-1060

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Macdonald, R. L.
Right arrow Articles by Han, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Macdonald, R. L.
Right arrow Articles by Han, H.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Medline Plus Health Information
*Angioplasty
*Transient Ischemic Attack
Hazardous Substances DB
*PAPAVERINE HYDROCHLORIDE
*POTASSIUM

(Stroke. 1995;26:1053-1060.)
© 1995 American Heart Association, Inc.


Articles

Angioplasty Reduces Pharmacologically Mediated Vasoconstriction in Rabbit Carotid Arteries With and Without Vasospasm

R. Loch Macdonald, MD, PhD, FRCS(C); John Zhang, MD, PhD Hongshik Han, BSc

From the Section of Neurosurgery, Department of Surgery, University of Chicago (Ill) (R.L.M., J.Z., H.H.), and the Divisions of Neurosurgery and Neuroradiology, The Toronto Hospital, University of Toronto (Ontario, Canada) (R.L.M.).

Background and Purpose We tested the hypothesis that vasospastic arteries do not reconstrict after angioplasty because angioplasty decreases smooth muscle contractility.

Methods Twenty-four rabbits had carotid angiography and placement of silicone elastomer sheaths around both carotid arteries in the neck. Sheaths were empty (control groups) or filled with clotted blood (vasospasm groups). Angiography was repeated 2 days later, and one carotid artery was dilated with a balloon catheter. Animals were killed 1, 5, or 28 days after angioplasty, and the carotid arteries were studied pharmacologically under isometric tension.

Results Before angioplasty, there was significant vasospasm in the vasospasm groups but not in the control groups (P<.05, ANOVA). Angioplasty produced significant, long-lasting dilation of arteries in the vasospasm groups. One and 5 days after angioplasty, arteries from control and vasospasm groups that had angioplasty had significantly reduced contractions to serotonin, KCl, and caffeine compared with arteries not subjected to angioplasty. Twenty-eight days after angioplasty, contractions were reduced in arteries subjected to vasospasm compared with controls, but there were no differences between arteries with or without angioplasty. At all times after angioplasty, vasospasm significantly decreased acetylcholine-induced relaxations of arteries contracted with serotonin. Relaxations were further decreased by angioplasty in the vasospasm group 1 day after angioplasty. Arterial wall compliance was significantly decreased in the vasospasm and control groups at all times after angioplasty, although there were no significant differences between arteries with and without angioplasty.

Conclusions These results suggest that arteries do not reconstrict after angioplasty because angioplasty decreases smooth muscle contractility. There was no evidence that angioplasty disrupted the arterial wall matrix, as judged by the lack of increase in arterial wall compliance after angioplasty.


Key Words: angioplasty, transluminal • subarachnoid hemorrhage • vasoconstriction • rabbits




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
K. Nakai, Y. Numaguchi, T. H. Foster, K. Shima, and M. Kikuchi
Endovascular Treatment Using Low-Power Ultraviolet Laser for Delayed Vasospasm in the Rabbit Carotid Artery Model
AJNR Am. J. Neuroradiol., November 1, 2002; 23(10): 1725 - 1731.
[Abstract] [Full Text] [PDF]