(Stroke. 1999;30:1702-1706.)
© 1999 American Heart Association, Inc.
Case Reports |
From the Department of Neurology, Ruhr University Bochum (T.P., J.F., H.P., T.B.), and Schering AG (S.W.), Berlin, Germany.
Correspondence to Dr Thomas Postert, Department of Neurology in St Josef Hospital, Ruhr-University Bochum, Gudrunstrasse 56, 44791 Bochum, Germany.
BackgroundSecond harmonic imaging (SHI) is a new ultrasound technique that is able to detect microbubbles in the tissue vascular space. The aim of this pilot study was to prove that this technique may detect focal abnormalities of cerebral echo-contrast enhancement in acute hemispheric stroke.
Case DescriptionsTwo male patients (aged 72 and 64 years) were included who presented with acute onset of severe hemiparesis and no established demarcation of the ischemic area in CT scans. After bolus application of galactose-based microbubbles, axial SHI examinations in a diencephalic plane of sections were performed using the transtemporal approach. Ultrasound investigations were recorded and evaluated offline. In both individuals demarcated focal abnormalities of cerebral contrast enhancement were detectable: in patient 1 the region of the lentiform nucleus and the adjacent parts of the temporoparietal lobe was affected, and in patient 2 a large region including the lentiform nucleus and cortical white matter was involved for at least 24 hours. Follow-up CT scans demonstrated a striatocapsular infarct in patient 1 and complete MCA infarction in patient 2, correlating with the presumed ischemic area in acute ultrasound examinations. The patient with complete MCA infarction showed missing contrast enhancement in the entire hemisphere of the affected side in follow-up SHI examinations. He died of malignant space-occupying brain edema. In the patient with the striatocapsular infarction, reappearance of echo-contrast enhancement in the ischemic area was assessable after 1 week.
ConclusionsSHI may identify focal abnormalities of cerebral echo-contrast enhancement in acute hemispheric stroke. Furthermore, this technique helps to determine size, localization, and prognosis of the ischemic region and could be useful for bedside assessment of echo-contrast agent distribution related to brain tissue perfusion.
Key Words: cerebral ischemia contrast media imaging, harmonic ultrasonography, transcranial
This article has been cited by other articles:
![]() |
E. Bartels and H.-J. Bittermann Transcranial Contrast Imaging of Cerebral Perfusion in Patients With Space-Occupying Intracranial Lesions J. Ultrasound Med., April 1, 2006; 25(4): 499 - 507. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Eyding, W. Wilkening, C. Krogias, T. Holscher, H. Przuntek, S. Meves, and T. Postert Validation of the Depletion Kinetic in Semiquantitative Ultrasonographic Cerebral Perfusion Imaging Using 2 Different Techniques of Data Acquisition J. Ultrasound Med., August 1, 2004; 23(8): 1035 - 1040. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Eyding, C Krogias, W Wilkening, and T Postert Detection of cerebral perfusion abnormalities in acute stroke using phase inversion harmonic imaging (PIHI): preliminary results J. Neurol. Neurosurg. Psychiatry, June 1, 2004; 75(6): 926 - 929. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Seidel, K. Meyer-Wiethe, G. Berdien, D. Hollstein, D. Toth, and T. Aach Ultrasound Perfusion Imaging in Acute Middle Cerebral Artery Infarction Predicts Outcome Stroke, May 1, 2004; 35(5): 1107 - 1111. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shiogai, N. Takayasu, T. Mizuno, M. Nakagawa, and H. Furuhata Comparison of Transcranial Brain Tissue Perfusion Images Between Ultraharmonic, Second Harmonic, and Power Harmonic Imaging Stroke, March 1, 2004; 35(3): 687 - 693. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Wiesmann, K. Meyer, T. Albers, and G. Seidel Parametric Perfusion Imaging With Contrast-Enhanced Ultrasound in Acute Ischemic Stroke Stroke, February 1, 2004; 35(2): 508 - 513. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Meves, W. Wilkening, T. Thies, J. Eyding, T. Holscher, M. Finger, G. Schmid, H. Ermert, and T. Postert Comparison Between Echo Contrast Agent-Specific Imaging Modes and Perfusion-Weighted Magnetic Resonance Imaging for the Assessment of Brain Perfusion Stroke, October 1, 2002; 33(10): 2433 - 2437. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. U. Harrer and C. Klotzsch Second Harmonic Imaging of the Human Brain: The Practicability of Coronal Insonation Planes and Alternative Perfusion Parameters Stroke, June 1, 2002; 33(6): 1530 - 1535. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-J. Rim, H. Leong-Poi, J. R. Lindner, D. Couture, D. Ellegala, H. Mason, M. Durieux, N. F. Kassel, and S. Kaul Quantification of Cerebral Perfusion With "Real-Time" Contrast-Enhanced Ultrasound Circulation, November 20, 2001; 104(21): 2582 - 2587. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Federlein, T. Postert, S Meves, S Weber, H Przuntek, and T. Buttner Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging J. Neurol. Neurosurg. Psychiatry, November 1, 2000; 69(5): 616 - 622. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Wiesmann and G. Seidel Ultrasound Perfusion Imaging of the Human Brain Stroke, October 1, 2000; 31(10): 2421 - 2425. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Seidel, C. Algermissen, A. Christoph, T. Katzer, M. Kaps, and R. W. Baumgartner Visualization of Brain Perfusion With Harmonic Gray Scale and Power Doppler Technology : An Animal Pilot Study Editorial Comment: An Animal Pilot Study Stroke, July 1, 2000; 31(7): 1728 - 1734. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Seidel, C. Algermissen, A. Christoph, L. Claassen, M. Vidal-Langwasser, and T. Katzer Harmonic Imaging of the Human Brain : Visualization of Brain Perfusion With Ultrasound Stroke, January 1, 2000; 31(1): 151 - 154. [Abstract] [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1999 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |