(Stroke. 1999;30:1827-1832.)
© 1999 American Heart Association, Inc.
Original Contributions |
From the Department of Neurology (D.W.D., J-U.K., R.T., B.W., P.Y., E.B.R.) and the Department of Cardiology and Angiology and Institute for Arteriosclerosis Research (J.S., M.C., T.W.), University of Münster (Germany).
Background and PurposeCardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and different provocation procedures. Currently, data on an appropriate time window for the appearance of contrast bubbles in the TCD recording after the injection of the contrast medium and the comparison of different provocation maneuvers to increase right-to-left shunting are insufficient.
MethodsForty-six patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with 6 injection modes was applied in a randomized way: (1) injection of 10 mL of agitated saline without Valsalva maneuver, (2) injection of 10 mL of agitated saline with Valsalva maneuver, (3) injection of 10 mL of a commercial galactose-based contrast agent (Echovist) without Valsalva maneuver, (4) injection of 10 mL of Echovist with Valsalva maneuver, (5) injection of 10 mL of Echovist with standardized Valsalva maneuver, and (6) injection of 10 mL of Echovist with coughing.
ResultsIn 20 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt-positive). Sixteen patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 10 patients were only positive on at least 1 TCD investigation but negative during TEE. The amount of microbubbles detected in the various tests decreased in the following order: Echovist and Valsalva maneuver, Echovist with coughing, Echovist and standardized Valsalva maneuver, saline with Valsalva maneuver, Echovist, and saline. With a time window of 20 to 25 seconds for the bubbles to appear in the TCD recording and with a sequence of first Echovist and Valsalva maneuver and then Echovist with coughing, all shunts were reliably identified with a specificity of 65% compared with TEE as the traditional gold standard. The time of first microbubble appearance was not helpful to distinguish between shunts detected on TEE and other shunts.
ConclusionsTCD performed twice with 2 provocation maneuvers using Echovist is a sensitive method to identify cardiac right-to-left shunts also identified by TEE.
Key Words: cerebrovascular disorders cerebral embolism foramen ovale, patent ultrasonography
This article has been cited by other articles:
![]() |
L. Caputi, M. R. Carriero, E. A. Parati, E. Onorato, F. Casilli, M. Berti, and G. P. Anzola Postural Dependency of Right to Left Shunt: Role of Contrast-Enhanced Transcranial Doppler and Its Potential Clinical Implications Stroke, August 1, 2008; 39(8): 2380 - 2381. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Sarkar, S. Ghosh, S. K. Ghosh, and A. Collier Role of transcranial Doppler ultrasonography in stroke Postgrad. Med. J., November 1, 2007; 83(985): 683 - 689. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Homma and R. L. Sacco Patent Foramen Ovale and Stroke Circulation, August 16, 2005; 112(7): 1063 - 1072. [Full Text] [PDF] |
||||
![]() |
B. Draganski, W. Blersch, S. Holmer, H. Koch, A. May, U. Bogdahn, T. Holscher, and F. Schlachetzki Detection of Cardiac Right-to-Left Shunts by Contrast-Enhanced Harmonic Carotid Duplex Sonography J. Ultrasound Med., August 1, 2005; 24(8): 1071 - 1076. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. Schuchlenz, G.P. Anzola, E. Morandi, F. Casilli, and E. Onorato Contrast Ultrasound Techniques in the Detection and Quantification of Patent Foramen Ovale: Myth Versus Reality * Response: Stroke, December 1, 2004; 35(12): 2755 - 2756. [Full Text] [PDF] |
||||
![]() |
N. Uzuner, S. Horner, G. Pichler, D. Svetina, and K. Niederkorn Right-to-Left Shunt Assessed by Contrast Transcranial Doppler Sonography: New Insights J. Ultrasound Med., November 1, 2004; 23(11): 1475 - 1482. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Devuyst, B. Piechowski-Jozwiak, T. Karapanayiotides, J.-W. Fitting, V. Kemeny, L. Hirt, L. A. Urbano, P. Arnold, G. van Melle, P.-A. Despland, et al. Controlled Contrast Transcranial Doppler and Arterial Blood Gas Analysis to Quantify Shunt Through Patent Foramen Ovale Stroke, April 1, 2004; 35(4): 859 - 863. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. W. Droste, S. Lakemeier, T. Wichter, J. Stypmann, R. Dittrich, M. Ritter, M. Moeller, M. Freund, and E. B. Ringelstein Optimizing the Technique of Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts Stroke, September 1, 2002; 33(9): 2211 - 2216. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. Schuchlenz, W. Weihs, A. Beitzke, J.-I. Stein, A. Gamillscheg, and P. Rehak Transesophageal Echocardiography for Quantifying Size of Patent Foramen Ovale in Patients With Cryptogenic Cerebrovascular Events Stroke, January 1, 2002; 33(1): 293 - 296. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Arquizan, J. Coste, P.-J. Touboul, and J.-L. Mas Is Patent Foramen Ovale a Family Trait? : A Transcranial Doppler Sonographic Study Stroke, July 1, 2001; 32(7): 1563 - 1566. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Karttunen, M. Ventila, M. Ikaheimo, M. Niemela, and M. Hillbom Ear Oximetry: A Noninvasive Method for Detection of Patent Foramen Ovale : A Study Comparing Dye Dilution Method and Oximetry With Contrast Transesophageal Echocardiography Stroke, February 1, 2001; 32(2): 448 - 453. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. W. Droste, K. Silling, J. Stypmann, M. Grude, V. Kemeny, T. Wichter, K. Kuhne, and E. B. Ringelstein Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts : Time Window and Threshold in Microbubble Numbers Stroke, July 1, 2000; 31(7): 1640 - 1645. [Abstract] [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1999 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |