(Stroke. 2000;31:907.)
© 2000 American Heart Association, Inc.
Original Contributions |
From the Neurology Division, Department of Medicine, University of Alberta, Alberta, Canada (Y.Y., Q.L.); Department of Neurology, Southern General Hospital, Glasgow, UK (D.G.G.); and the Department of Medicine and Therapeutics, University of Glasgow, Glasgow, Scotland, UK (K.R.L.).
Correspondence to Dr Yi Yang, MD, PhD, Rm 530, HMRC, Cerebrovascular Laboratory, University of Alberta, Edmonton, Alberta, Canada T6G 2S2. E-mail yiy{at}ualberta.ca
Background and PurposeSpontaneous echo contrast in cardiac chamber has been indicated as a source of cerebral embolism. The nature of the echocardiographic smokelike signal is still not fully understood. This study was designed to regenerate spontaneous echo contrast and verify its thromboembolic characters in an in vitro model.
MethodsSpontaneous echo contrast was reproduced in an expansion chamber under low flow conditions in a close circulation system. The spontaneous echo contrast was monitored and recorded with a 2-dimensional cardiosonography system and a transcranial Doppler device. Meanwhile, clinically commonly encountered embolic materials such as whole-blood clots, platelet aggregaterich plasma, air bubbles, and 100-mL normal saline were injected into this monitored circuit. The differentiation of spontaneous echo contrast from emboli was performed by both visual observations of the echo images and offline Doppler signal intensity analysis. Average signal intensities produced by spontaneous contrast and injection of embolic materials and saline were compared. Furthermore, the effect of Doppler-detected flow velocity on generation of spontaneous contrast was also evaluated.
ResultsSpontaneous echo contrast was reproduced at low flow settings (90 to 120 mL/min) in this model. There was no significant difference in average signal intensity between the flow with spontaneous echo contrast and that without the echo (P=0.71). However, injection of embolic materials or normal saline did not generate smokelike image but caused much higher average signal intensity than the flow with spontaneous contrast (P<0.001). Injection of normal saline also increased average signal intensity.
ConclusionsOur results suggest that smokelike echo is a special echo phenomenon occurring at low flow situations and does not itself produce material capable of embolizing into the systemic circulation.
Key Words: cerebral embolism spontaneous echo contrast ultrasound, Doppler, transcranial
This article has been cited by other articles:
![]() |
Writing Committee Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society Europace, September 1, 2006; 8(9): 651 - 745. [Full Text] [PDF] |
||||
![]() |
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al. ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation--Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society J. Am. Coll. Cardiol., August 15, 2006; 48(4): 854 - 906. [Full Text] [PDF] |
||||
![]() |
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al. ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society J. Am. Coll. Cardiol., August 15, 2006; 48(4): e149 - e246. [Full Text] [PDF] |
||||
![]() |
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al. ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society Circulation, August 15, 2006; 114(7): e257 - e354. [Full Text] [PDF] |
||||
![]() |
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al. ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation--Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society Circulation, August 15, 2006; 114(7): 700 - 752. [Full Text] [PDF] |
||||
![]() |
Authors/Task Force Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation executive summary: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society Eur. Heart J., August 2, 2006; 27(16): 1979 - 2030. [Full Text] [PDF] |
||||
![]() |
R. Rastegar, D. J. Harnick, P. Weidemann, V. Fuster, B. Coller, J. J. Badimon, J. Chesebro, and M. E. Goldman Spontaneous echo contrast videodensity isflow-related and is dependent on the relative concentrations of fibrinogen and red blood cells J. Am. Coll. Cardiol., February 19, 2003; 41(4): 603 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yang, D. G. Grosset, Q. Li, A. Shuaib, and K. R. Lees Turbulence and Circulating Cerebral Emboli Detectable at Doppler Ultrasonography: A Differentiation Study in a Stenotic Middle Cerebral Artery Model AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1229 - 1236. [Abstract] [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2000 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |