Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2002;33:2433-2437
doi: 10.1161/01.STR.0000032246.85531.8E
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meves, S. H.
Right arrow Articles by Postert, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meves, S. H.
Right arrow Articles by Postert, T.
Related Collections
Right arrow CT and MRI
Right arrow Brain Circulation and Metabolism
Right arrow Doppler ultrasound, Transcranial Doppler etc.

(Stroke. 2002;33:2433.)
© 2002 American Heart Association, Inc.


Original Contributions

Comparison Between Echo Contrast Agent-Specific Imaging Modes and Perfusion-Weighted Magnetic Resonance Imaging for the Assessment of Brain Perfusion

Saskia H. Meves, MD; Wilko Wilkening, MSc; Tammo Thies, BA; Jens Eyding, MD; Thilo Hölscher, MD; Michael Finger, PhD; Gebhard Schmid, MD; Helmut Ermert, PhD Thomas Postert, MD for the Ruhr Center of Competence for Medical Engineering

From the Departments of Neurology (S.H.M., T.T., J.E., M.F., T.P.), Electrical Engineering (W.W., H.E.), and Radiology (G.S.), Ruhr University, Bochum, and Department of Neurology, University Regensburg, Regensburg (T.H.), Germany.

Correspondence to Dr T. Postert, MD, Department of Neurology, St. Vincenz-Krankenhaus, Kiesau 14, D-33098 Paderborn, Germany. E-mail t.postert{at}vincenz.de

Background and Purpose— Contrast burst imaging (CBI) and time variance imaging (TVI) are new ultrasonic imaging modes enabling the visualization of intravenously injected echo contrast agents in brain parenchyma. The aim of this study was to compare the quantitative ultrasonic data with corresponding perfusion-weighted MRI data (p-MRI) with respect to the assessment of brain perfusion.

Methods— Twelve individuals with no vascular abnormalities were examined by CBI and TVI after an intravenous bolus injection of 4 g galactose-based microbubble suspension (Levovist) in a concentration of 400 mg/mL. Complementary, a dynamic susceptibility contrast MRI, ie, p-MRI, of each individual was obtained. In both ultrasound (US) methods and p-MRI, time-intensity curves were calculated offline, and absolute time to peak intensities (TPI), peak intensities (PI), and peak width (PW) of US investigations and TPI, relative cerebral blood flow (CBF) and relative cerebral blood volume (CBV) of p-MRI examinations were determined in the following regions of interest (ROIs): lentiform nucleus (LN), white matter (WM), posterior (PT), and anterior thalamus (AT). In addition, the M2 segment of the middle cerebral artery (MCA) was evaluated in the US, and the precentral gyrus (PG) was examined in the p-MRI examinations. In relation to a reference parenchymal ROI (AT), relative TPIs were compared between the US and p-MRI methods and relative PI of US investigations with the ratio of CBF (rCBF) of p-MRI examinations in identical ROIs.

Results— Mean TPIs varied from 18.3±5.0 (AT) to 20.1± 5.8 (WM) to 17.2±4.9 (MCA) seconds in CBI examinations and from 19.4±5.3 (AT) to 20.4±4.3 (WM) to 17.3±4.0 (MCA) seconds in TVI examinations. Mean PIs were found to vary from 581.9±342.4 (WM) to 1522.9±574.2 (LN) to 3400.9± 621.7 arbitrary units (MCA) in CBI mode and from 7.5±4.6 (WM) to 17.5±4.9 (LN) to 46.3±7.1 (MCA) arbitrary units in TVI mode. PW ranged from 7.3±4.5 (AT) to 9.1±4.0 (LN) to 24.3±12.8 (MCA) seconds in CBI examinations and from 7.1±3.9 (AT) to 8.7±3.5 (LN) to 26.7±18.2 (MCA) seconds in TVI examinations. Mean TPI was significantly shorter and mean PI and mean PW were significantly higher in the MCA compared with all other ROIs (P<0.05). Mean TPI of the p-MRI examinations ranged from 22.0±6.9 (LN) to 23.0±6.8 (WM) seconds; mean CBF ranged from 0.0093± 0.0041 (LN) to 0.0043±0.0021 (WM). There was no significant difference in rTPI in any ROI between US and p-MRI measurements (P>0.2), whereas relative PIs were significantly higher in areas with lower insonation depth such as the LN compared with rCBF.

Conclusions— In contrast to PI, TPI and rTPI in US techniques are robust parameters for the evaluation of cerebral perfusion and may help to differentiate physiological and pathological perfusion in different parenchymal regions of the brain.


Key Words: contrast media • magnetic resonance imaging, perfusion-weighted • perfusion • ultrasonography, Doppler, transcranial




This article has been cited by other articles:


Home page
Eur Heart JHome page
D. Duerschmied, L. Olson, M. Olschewski, A. Rossknecht, G. Freund, C. Bode, and C. Hehrlein
Contrast ultrasound perfusion imaging of lower extremities in peripheral arterial disease: a novel diagnostic method
Eur. Heart J., February 1, 2006; 27(3): 310 - 315.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Holscher, W. Wilkening, B. Draganski, S. H. Meves, J. Eyding, H. Voit, U. Bogdahn, H. Przuntek, and T. Postert
Transcranial Ultrasound Brain Perfusion Assessment With a Contrast Agent-Specific Imaging Mode: Results of a Two-Center Trial
Stroke, October 1, 2005; 36(10): 2283 - 2285.
[Abstract] [Full Text] [PDF]