Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2005;36:2105-2109
Published online before print September 8, 2005, doi: 10.1161/01.STR.0000181753.40455.07
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
36/10/2105    most recent
01.STR.0000181753.40455.07v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heijenbrok-Kal, M. H.
Right arrow Articles by Myriam Hunink, M.G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heijenbrok-Kal, M. H.
Right arrow Articles by Myriam Hunink, M.G.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Carotid Artery Disease
*Stroke
*Transient Ischemic Attack
Related Collections
Right arrow Cardiovascular imaging agents/Techniques
Right arrow Carotid Stenosis
Right arrow Imaging
Right arrow Angiography
Right arrow Doppler ultrasound, Transcranial Doppler etc.

(Stroke. 2005;36:2105.)
© 2005 American Heart Association, Inc.


Original Contributions

Diagnostic Performance of Duplex Ultrasound in Patients Suspected of Carotid Artery Disease

The Ipsilateral Versus Contralateral Artery

Majanka H. Heijenbrok-Kal, PhD; Paul J. Nederkoorn, MD, PhD; Erik Buskens, MD, PhD; Yolanda van der Graaf, MD, PhD M.G. Myriam Hunink, MD, PhD

From the Program for the Assessment of Radiological Technology (ART Program), Department of Epidemiology and Biostatistics and the Department of Radiology, Erasmus MC-University Medical Center Rotterdam, the Netherlands (M.H.H.-K., M.G.M.H.); the Department of Neurology, Academic Medical Center Amsterdam, the Netherlands (P.J.N.); Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, the Netherlands (E.B., Y.vdG.); and the Department of Health Policy and Management, Harvard School of Public Health, Boston, Mass (M.G.M.H.).

Correspondence to Majanka H. Heijenbrok-Kal, PhD, Erasmus MC-University Medical Center Rotterdam, Room EE21-18, PO Box 1738, 3000 DR Rotterdam, The Netherlands. E-mail m.heijenbrok{at}erasmusmc.nl

Background and Purpose— To evaluate duplex ultrasonographic thresholds for the determination of 70% to 99% stenosis of the ipsilateral and contralateral internal carotid artery in patients with symptoms of amaurosis fugax, transient ischemic attack (TIA), or minor stroke based on 2 criteria: maximizing accuracy and optimizing cost-effectiveness and to compare these with current recommendations.

Methods— From January 1997 to January 2000, a prospective multicenter study was conducted including 350 consecutive patients with symptoms of amaurosis fugax, TIA, or minor stroke who underwent bilateral duplex ultrasonography and digital subtraction angiography. A linear regression analysis was performed to estimate the degree of angiographic stenosis as a function of the peak systolic velocity (PSV). PSV thresholds were calculated for the ipsilateral and contralateral carotid arteries based on maximizing accuracy and optimizing cost-effectiveness.

Results— The PSV measurements significantly overestimated the angiographic stenosis in the contralateral artery (9.5%; 95% CI, 6.3% to 12.7%) compared with the ipsilateral carotid artery. The recommended PSV threshold for the diagnosis of 70% to 99% stenosis is 230 cm/s. Maximizing accuracy, the optimal PSV threshold for the ipsilateral artery was 280 cm/s, and for the contralateral artery, 370 cm/s for diagnosing a 70% to 99% stenosis. Optimizing cost-effectiveness, the optimal PSV threshold was 220 cm/s for ipsilateral and 290 cm/s for contralateral carotid arteries.

Conclusions— PSV measurements overestimate the degree of angiographic stenosis in the contralateral carotid artery in patients with symptoms of amaurosis fugax, TIA, or minor stroke. Separate PSV thresholds should be used for the ipsilateral and contralateral carotid artery. PSV thresholds that optimize cost-effectiveness differ from the recommended thresholds and from thresholds that maximize accuracy.


Key Words: carotid arteries • carotid stenosis • ultrasonography