(Stroke. 2005;36:1731.)
© 2005 American Heart Association, Inc.
Original Contributions |
From Clinical Neuroscience, Department of Cardiac and Vascular Sciences, St Georges Hospital Medical School, London, UK.
Correspondence to Hugh Markus, Clinical Neuroscience, St Georges Hospital Medical School, Cranmer Terr, London, SW17 0RE, UK. E-mail hmarkus{at}sghms.ac.uk
Background and Purpose Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound transducer frequencies, has been developed. An initial study with a small sample size suggested it provided excellent discrimination. We performed a validation study in subjects with embolic signals of known nature.
Methods Gaseous embolic signals were obtained in 7 patients with known patient foramen ovale by intravenous injection of agitated saline injections. Solid embolic signals were obtained in patients with symptomatic carotid stenosis (N=23). Discrimination of the 2 using the Embo-Dop system dual-frequency system was assessed. It was compared with discrimination using embolic signal maximum intensity with an intensity threshold.
Results One hundred forty-five solid embolic signals were recorded from carotid stenosis patients. Seventy-three were classified as solid and 72 as gaseous by the Embo-Dop system. Six hundred forty-eight gaseous embolic signals were recorded from 7 patients with patent foramen ovale. Six hundred twenty-five were classified as gaseous and 23 as solid. This gave a sensitivity of 50.3% and specificity of 96.5% for detecting solid embolic signals. Discrimination was better than using a simple intensity threshold.
Conclusions The Embo-Dop dual-frequency system allows better discrimination than a simple intensity threshold but it is not accurate enough for use in clinical or research studies. Further work is needed to develop reliable clinical systems for discrimination of emboli.
Key Words: cerebral circulation embolism ultrasonography, Doppler, transcranial
This article has been cited by other articles:
![]() |
M. Barak, M. Kabha, D. Norman, M. Soudry, Y. Kats, and S. Milo Cerebral Microemboli During Hip Fracture Fixation: A Prospective Study Anesth. Analg., July 1, 2008; 107(1): 221 - 225. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Guerrieri Wolf, B. P. Choudhary, Y. Abu-Omar, and D. P. Taggart Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 512 - 520. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Motallebzadeh, J. M. Bland, H. S. Markus, J. C. Kaski, and M. Jahangiri Neurocognitive Function and Cerebral Emboli: Randomized Study of On-Pump Versus Off-Pump Coronary Artery Bypass Surgery Ann. Thorac. Surg., February 1, 2007; 83(2): 475 - 482. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. G. Wolf, Y. Abu-Omar, B. P. Choudhary, D. Pigott, and D. P. Taggart Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: The effect of an aortic side-biting clamp and two clampless devices J. Thorac. Cardiovasc. Surg., February 1, 2007; 133(2): 485 - 493. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. H. Evans Embolus Differentiation Using Multifrequency Transcranial Doppler Stroke, July 1, 2006; 37(7): 1641 - 1641. [Full Text] [PDF] |
||||
![]() |
D. Russell, R. Brucher, H. S. Markus, and M. Punter Embolus Detection and Differentiation Using Multifrequency Transcranial Doppler * Response: Stroke, February 1, 2006; 37(2): 340 - 342. [Full Text] [PDF] |
||||
![]() |
M. Schoenburg, J. Baer, N. Schwarz, E. Stolz, M. Kaps, G. Bachmann, and T. Gerriets EmboDop: Insufficient Automatic Microemboli Identification Stroke, February 1, 2006; 37(2): 342 - 343. [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2005 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |