Donate Help Contact The AHA Sign In Home
American Heart Association
Stroke
Search: search_blue_button Advanced Search
Stroke. 2006;37:1301-1306
Published online before print March 23, 2006, doi: 10.1161/01.STR.0000217329.16739.8f
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
37/5/1301    most recent
01.STR.0000217329.16739.8fv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schneider, F.
Right arrow Articles by Nedelmann, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schneider, F.
Right arrow Articles by Nedelmann, M.
Related Collections
Right arrow Animal models of human disease
Right arrow Computerized tomography and Magnetic Resonance Imaging

(Stroke. 2006;37:1301.)
© 2006 American Heart Association, Inc.


Original Contributions

Brain Edema and Intracerebral Necrosis Caused by Transcranial Low-Frequency 20-kHz Ultrasound

A Safety Study in Rats

Felicitas Schneider, MD; Tibo Gerriets, MD; Maureen Walberer, DVM; Clemens Mueller, PhD; Roman Rolke, MD; Bernhard M. Eicke, MD; Juergen Bohl, MD; Oliver Kempski, MD; Manfred Kaps, MD; Georg Bachmann, MD; Marianne Dieterich, MD Max Nedelmann, MD

From the Department of Neurology (F.S., R.R., B.M.E., M.D., M.N.), Johannes Gutenberg-University, Mainz, Germany; Department of Neurology (T.G., M.W., M.K.), University Giessen, Germany; Department of Radiology - Experimental Neurology Research Group (T.G., M.W., C.M., G.B.), Kerkhoff Clinic Bad Nauheim, Germany; Department of Neuropathology (J.B.), Johannes Gutenberg-University, Mainz, Germany; and Institute for Neurosurgical Pathophysiology (O.K.), Johannes Gutenberg University, Mainz, Germany.

Correspondence to Max Nedelmann, MD, Department of Neurology, Johannes Gutenberg University, Langenbeckstrasse 1, 55101 Mainz, Germany. E-mail nedelmann{at}neurologie.klinik.uni-mainz.de

Background and Purpose— Ultrasound-accelerated thrombolysis is a promising approach toward acute stroke treatment. In previous in vitro studies, we demonstrated enhanced thrombus destruction induced by 20-kHz ultrasound. However, little is known about biological interactions of low-frequency ultrasound with brain tissue. The aim of this in vivo MRI study was to assess safety aspects of transcranial low-frequency ultrasound in rats.

Methods— The cranium of 33 male Wistar rats was sonificated for 20 minutes (20-kHz continuous wave). Power output was varied between 0 and 2.6 W/cm2. Tympanal and rectal temperature was monitored. Diffusion-weighted imaging and T2-weighted imaging was performed before and 4 hours, 24 hours, and 5 days after sonification. Apparent diffusion coefficients (ADCs) and T2 relaxation time (T2-RT) were measured in regions of interest in the cortex and the basal ganglia. The animals were euthanized for histological evaluation thereafter.

Results— Tympanal temperature increased significantly during insonation with 1.1 and 2.6 W/cm2. ADCs decreased significantly at 0.5 and 1.1 W/cm2, indicating cytotoxic edema. T2-RT increased significantly in the 0.5 and 1.1 W/cm2 group, consistent with vasogenic edema. No changes were detectable in the low-power output group (0.2 W/cm2). After sonification with 2.6 W/cm2, a significant loss of neurons could be detected on histopathology. Furthermore, 3 animals developed circumscript cortical lesions that could be identified as parenchymal necrosis.

Conclusion— Low-frequency ultrasound caused vasogenic and cytotoxic brain edema and intracerebral necrosis in a dose-dependent fashion. This study indicates therapeutic low-frequency ultrasound as being potentially harmful and underlines the necessity of careful evaluation in further animal models.


Key Words: ultrasonography • thrombolysis • stroke




This article has been cited by other articles:


Home page
StrokeHome page
T. Saguchi, H. Onoue, M. Urashima, T. Ishibashi, T. Abe, and H. Furuhata
Effective and Safe Conditions of Low-Frequency Transcranial Ultrasonic Thrombolysis for Acute Ischemic Stroke: Neurologic and Histologic Evaluation in a Rat Middle Cerebral Artery Stroke Model
Stroke, March 1, 2008; 39(3): 1007 - 1011.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Wilhelm-Schwenkmezger, P. Pittermann, K. Zajonz, O. Kempski, M. Dieterich, and M. Nedelmann
Therapeutic Application of 20-kHz Transcranial Ultrasound in an Embolic Middle Cerebral Artery Occlusion Model in Rats: Safety Concerns
Stroke, March 1, 2007; 38(3): 1031 - 1035.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
M. Reinhard, T. Els, and A. Hetzel
Response to Letter by Gerriets et al
Stroke, February 1, 2007; 38(2): 252 - 252.
[Full Text] [PDF]


Home page
StrokeHome page
T. Gerriets, M. Walberer, M. Nedelmann, G. Bachmann, and M. Kaps
Blood-Brain Barrier Disruption by Low-Frequency Ultrasound
Stroke, February 1, 2007; 38(2): 251 - 251.
[Full Text] [PDF]