| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Stroke. 2007;38:2855.)
© 2007 American Heart Association, Inc.
Research Letters |
From the Department of Neuroradiology, University of Würzburg, Germany.
Correspondence to Dr M. Bendszus, Department of Neuroradiology, University of Würzburg, Josef-Schneider-Str. 11, D-97080 Würzburg, Germany. E-mail bendszus{at}neuroradiologie.uni-wuerzburg.de
Abstract
Background and Purpose— To assess safety and efficacy data of a new bioactive coil (Cerecyte) which is loaded with polyglycolic acid on the inside of the coil.
Methods— Fifty-four patients harboring 55 aneurysms were treated with Cerecyte coils. These aneurysms were matched in localization and size with aneurysms treated with bare platinum coils.
Results— Periprocedural complications and handling did not differ between both groups. Initial aneurysm occlusion was comparable in both treatment groups. At 6 months angiographic follow-up, the aneurysms occluded with Cerecyte coils had a higher chance for complete occlusion (P=0.045) and tended to a lower retreatment rate (P=0.056).
Conclusions— Cerecyte coils are as safe as bare platinum coils in the endovascular occlusion of aneurysms. This matched pair analysis indicates a higher occlusion rate of aneurysms occluded with Cerecyte coils.
Key Words: aneurysm bioactive coil endovascular
This article has been cited by other articles:
![]() |
I. Linfante, M.J. DeLeo III, M.J. Gounis, C.S. Brooks, and A.K. Wakhloo Cerecyte versus Platinum Coils in the Treatment of Intracranial Aneurysms: Packing Attenuation and Clinical and Angiographic Midterm Results AJNR Am. J. Neuroradiol., September 1, 2009; 30(8): 1496 - 1501. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. Ferns, M. E.S. Sprengers, W. J. van Rooij, G. J.E. Rinkel, J. C. van Rijn, S. Bipat, M. Sluzewski, and C. B.L.M. Majoie Coiling of Intracranial Aneurysms: A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates Stroke, August 1, 2009; 40(8): e523 - e529. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Cloft and D. F. Kallmes Statistical Error in Interpretation of Aneurysm Coil Results Stroke, February 1, 2008; 39(2): e29 - e29. [Full Text] [PDF] |
||||
![]() |
A. J. Bartsch, C. F. Beckmann, L. Solymosi, and M. Bendszus Response to Letter by Cloft and Kallmes Stroke, February 1, 2008; 39(2): e30 - e30. [Full Text] [PDF] |
||||
|
Stroke Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |