Published Online
on April 24, 2008

Stroke. 2008
Published online before print April 24, 2008, doi: 10.1161/STROKEAHA.107.503862
A more recent version of this article appeared on July 1, 2008
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
39/7/2105    most recent
STROKEAHA.107.503862v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ionita, C. N.
Right arrow Articles by Mocco, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ionita, C. N.
Right arrow Articles by Mocco, J
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Brain Aneurysm
Related Collections
Right arrow Animal models of human disease
Right arrow Cerebral Aneurysm, AVM, & Subarachnoid hemorrhage
Right arrow Aneurysm, AVM, hematoma

Submitted on September 5, 2007
Revised on October 27, 2007
Accepted on December 6, 2007

Asymmetric Vascular Stent. Feasibility Study of a New Low-Porosity Patch-Containing Stent

Ciprian N. Ionita PhD; Ann M. Paciorek BS; Kenneth R. Hoffmann PhD; Daniel R. Bednarek PhD; Junichi Yamamoto MD, PhD; John Kolega PhD; Elad I. Levy MD; L. Nelson Hopkins MD; Stephen Rudin PhD; and J Mocco MD, MS*

From the Departments of Neurosurgery (C.N.I., J.M., K.R.H., J.Y., E.I.L., L.N.H., S.R., J.M.), Radiology (C.N.I., D.R.B., E.I.L., L.N.H., S.R.), and Pathology (J.K.) and Toshiba Stroke Research Center (C.N.I., A.P., K.R.H., D.R.B., J.Y., E.I.L., L.N.H., S.R., J.M.), School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York; and the Department of Neurosurgery (J.Y., E.I.L., L.N.H., J.M.), Millard Fillmore Gates Hospital, Kaleida Health, Buffalo, New York.

* To whom correspondence should be addressed. E-mail: jmocco{at}buffns.com.

Background and Purpose—Intracranial aneurysm (IA) treatment through hemodynamic modification with novel stent designs is a burgeoning area of research. We present a feasibility study for a new low-porosity patch-containing stent designed to treat intracranial aneurysms. The device is deployed so the patch covers the aneurysm neck ensuring strong flow diversion away from the aneurysm while keeping a low probability of occlusion of perforating vessels.

Methods—We created 17 side-wall aneurysms in 6 dogs, 2 per carotid artery if animal size permitted. Twelve proximal aneurysms were treated with AVSs: 5 distal aneurysms were untreated, serving as controls against self-thrombosis; 7 treated aneurysms were fully-covered; and 5 were partially-covered. After 4 weeks, a final angiogram was performed and aneurysms were explanted. Angiograms acquired pre- and posttreatment and at 4-week follow-up were analyzed quantitatively using normalized time-density curves (NTDC). Cone-beam micro-CT and histological specimen analysis were then performed.

Results—Posttreatment, NTDC average peaks dropped to 45% of initial values for the partially-covered aneurysms and 78% for the fully-covered aneurysms. Cone-beam micro-CT imaging performed at 4 weeks posttreatment showed partial thrombosis in 4 of 5 partially-covered aneurysms and complete thrombosis in all fully-covered aneurysms. Histology revealed neointimal coverage of all asymmetrical patch regions and thrombus formation in both fully- and partially-covered aneurysms. Four-week follow-up was not done for 1 animal (2 controls, 2 treated) that expired because of groin hemorrhage and for another animal (1 aneurysm) with an occluded carotid.

Conclusions—We demonstrate aneurysmal blood flow diversion using a new low-porosity patch-containing asymmetrical vascular stent in a canine side-wall aneurysm model. Overall results are encouraging and support continued AVS development.


Key words: aneurysm • stent • canine model • time-density curve




This article has been cited by other articles:


Home page
StrokeHome page
C. N. Ionita, A. M. Paciorek, A. Dohatcu, K. R. Hoffmann, D. R. Bednarek, J. Kolega, E. I. Levy, L. N. Hopkins, S. Rudin, and J. D. Mocco
The Asymmetric Vascular Stent: Efficacy in a Rabbit Aneurysm Model
Stroke, March 1, 2009; 40(3): 959 - 965.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
C. Sadasivan, L. Cesar, J. Seong, A. Rakian, Q. Hao, F. O. Tio, A. K. Wakhloo, and B. B. Lieber
An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms: Evaluation in the Rabbit Elastase-Induced Model
Stroke, March 1, 2009; 40(3): 952 - 958.
[Abstract] [Full Text] [PDF]